LIGHTING PLOT-Z001.0

site plan 1 page
Meeting: portal event 907 (no meeting page on file)
Agenda item: Old Business — Ameriland Brook, LLC - 352 South Riverside Avenue (79.13-1-74) Application for Site Plan Approval and any associated approvals, including any waiver of off-street parking spaces for a mixed-use building
Site plan, 1 page. Attached to agenda item: “Old Business — Ameriland Brook, LLC - 352 South Riverside Avenue (79.13-1-74) Application for Site Plan Approval and any associated approvals, including any waiver of off-street parking spaces for a mixed-use building”
Retrieved 2026-04-15 from the village's meeting portal. View the original PDF ↗
Also attached to this agenda item: 352 S RIVERSIDE AVE DRAFT As of 12.04.2023
NEW PARKING LOT PARCEL 2 PROPOSED 3 STORY WITH CELLAR EXISTING 1 STORY WITH CELLAR EXISTING 3-STORY FRAME BUILDING EXISTING 1-STORY FRAME BUILDING SUNOCO GAS STATION WALKWAY (NEW)  LIGHT BASE DETAIL FOUNDATION BY OTHERS VARIES (SEE LUMINAIRE SCHEDULE) POLE THREADED BOLT PROJECTION (2 1/2" MIN., 3" MAX.) 2" HANDHOLE 1'-6" 8"~ BOLT CIRCLE PROVIDE 3"x3" HOLE IN BASE & LEVELING PLATE FOR CONDUIT ACCESS 3/4" STEEL BASE PLATE (10"x10") 1/4" STEEL LEVELING PLATE (10"x10") 3/4" GROUT 4,000 PSI MIN. LIGHT AS SPEC. FINISH GRADE LUMINAIRE SCHEDULE SYMBOL LABEL QTY. MTG. HT. WATTS A FLCLED-120W-DOUBLE 90@20'AG- TILT 40 20' B FLCLED-120W-SINGLE @20'AG - TILT 40 20' C CWPB LED - WALL PACK 18" - #DC200L.56W.50K 15' CALCULATION SUMMARY LABEL AVG. MAX MIN. AVG/MIN MAX/MIN OVERALL 2.77 5.0 0.0 N/A N/A PARKING 3.78 5.0 0.0 N/A N/A LIGHT BASE DETAIL FOUNDATION BY OTHERS VARIES (SEE LUMINAIRE SCHEDULE) POLE THREADED BOLT PROJECTION (2 1/2" MIN., 3" MAX.) 2" HANDHOLE 1'-6" 8"~ BOLT CIRCLE PROVIDE 3"x3" HOLE IN BASE & LEVELING PLATE FOR CONDUIT ACCESS 3/4" STEEL BASE PLATE (10"x10") 1/4" STEEL LEVELING PLATE (10"x10") 3/4" GROUT 4,000 PSI MIN. LIGHT AS SPEC. FINISH GRADE FIXTURE-C: WALL MOUNTED FLOOD LIGHT FIXTURE FIXTURE-A&B: PARKING LOT LIGHT FIXTURE (1 OR 2 BULBS) Project Info.: Revision: Date: No.: of Drawing Title: NOTE: Drawing may be printed at reduced scale Drawn by: HT Checked by: No. of Sheet(s): Seal / Stamp: Drawn on: Drawing No.: Job No. / DOB Sticker: ENLARGEMENT 352 S RIVERSIDE AVENUE, NY 10520 11.20.2023 D.O.B APPROVAL STAMP Architecture, Zoning & Building Code, Interior Design Address : 30-05 Stratton Street, Queens, NY 11354 Phone : 718.878.6295 Email : abllcnyc@gmail.com E-001.00 ELECTRICAL SITE LIGHTING PLAN