80 Morningside A-2 CONST DWG
application
1 page
Meeting: portal event 950 (no meeting page on file)
Agenda item: New Business — Rossoff, Fred & Jessica, Owners--80 Morningside Drive-Located in a RA-9 Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.9 Block 6 Lot 5. Request a total side yard variance from Village Zoning Code Section 230-33A for a replacement deck.
Application, 1 page. Attached to agenda item: “New Business — Rossoff, Fred & Jessica, Owners--80 Morningside Drive-Located in a RA-9 Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.9 Block 6 Lot 5. Request a total”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
80 Morningside A-1 CONST DWG
80 Morningside Neighbor Letters of Support
80 Morningside ZBA REDACTED application
80 Morningside Zoning Site Survey
80 Morningside Zoning Site photos 01-S-1 SITE PHOTOS
80 Morningside previous ZBA variance
Extracted text
12" FOOTINGS TO
42" BELOW GRADE
-3'-6"
0"
8R@8-1/4" MAX
7R@ 8-1/2" MAX
X4 POST
X4 SUPPORT
X4 SUPPORT
0"H PICKET W/
BETWEEN
2X8 RIM JOIST
(3) 2X8 DROP GIRDER
2X8 RIM JOIST
(3) 2X8 DROP
GIRDER
6X6 PT POST
EXIST DR TO BE
RE-TRIMMED
ROOFING OVER EXIST
DR TO BE REDONE
EXIST DR TO
REMAIN
5 4" COMPOSITE DECKING
AS SELECTED BY
HOMEOWNER
2x10" JOIST 12"O.C.
(3) 2x12 GIRDER
5 x 10 NAILS
GALV. STRAP ANCHOR
6x6 P.T. POST
COPPER FLASHING
OVER EPDM
ROOFING & FRAMING
LEDGERLOK TYPE
FASTENERS 24"O.C.
MAX
JOIST HANGER
12" DIA. CONC. FOOTING
2x6 WOOD RAIL
CAP
2x4 STRETCHER UNDER HANDRAIL
1/4" S.S. CABLE RAIL SYSTEM
2x10 BLOCKING
@ 4x4 POST
2x10 RIM JOIST
(2) 3/8" BOLTS @ EA. POST
3/4" x FASCIA BOARD
4x4 P.T. POST
1 SIMPSON DTT1Z DECK TENSION TIE.
FASTENED TO EXIST SILL PLATE EA.
END OF DECK W/ ADD TIES AT 1/3
POINTS ALONG DECK LENGTH AT
HOUSE. SILL PLATE FASTENER TO
HAVE 3" MIN EMBEDMENT
EXIST DOOR
TO REMAIN
EPDM ROOFING UNDER
DECKING DRAPED
BETWEEN JOISTS &
SLOPED AWAY FROM
HOUSE
AZAK TYPE BEAD 7 BOARD
PANELS ATTACHED TO THE
UNDERSIDE OF THE DECK,
TO STOP 1-1/2" FROM RIM
JOIST / FASCIA
GAP IN WOOD
TO ACT AS A
DRAIN
2x10 P.T. LEDGER
LINE OF EXIST HOUSE
GALV. BASE CONNECTOR
1/2" "J" BOLT
FINISH GRADE
A-2
1"
8"
11"
MAX
3-3/4"
BLUESTONE
SPACE IN TRIANGLE UNDER
RAIL NOT TO ALLOW A 6"
SPHERE TO PASS THROUGH,
PER NYS RES. CODE
2x6 STAIR TREADS
2x8 RIPPED TO SIZE
2x12 STRINGER
1" NOSING
DIA. LESS THAN
6"
DECKING
-3'-6"
12" FOOTINGS TO
42" BELOW GRADE
6X6 PT POST
EXIST GRADE
2X8 RIM JOIST
(3) 2X8 DROP GIRDER
8@ 8-1/4"MAX
7@ 8-1/4"MAX
3'-0"
2X8 RIM JOIST
LINE OF HOUSE
3-3/4"
SPACING
MAX.
.
3-3/4"
SPACING
MAX.
.
6'-0"
4X4 POST
2X4 SUPPORT
2X4 SUPPORT
6'-0"H PICKET W/
2" BETWEEN
FLUSH MTD CLG
FAN AS
SELECTED BY
HOMEOWNER
SURFACE MTD
OVERHEAD LED
LIGHT FIXTURES
AS SELECTED BY
HOMEOWNER
5'-0"
8'-0"
SWITCHING AS
DIRECTED BY
HOMEOWNER
5'-0"
7'-0"
2'-0"
2'-0"
3'-0"
BEAD BOARD
CEILING @ UNDER
SIDE OF FRAMING
DN
DN
WATERPROOFING
MEMBRANE TO SLOPE
TO GUTTER NEXT TO
DROP BEAM
DROP BEAM
GUTTER MTD TO BEAM
EPDM RUBBER ROOF TO BE FULLY
ADHERED TO REBUILT AREA OVER
DOOR & TO EXTEND UP AND UNDER
EXIST DOOR SILL
EXIST AWNING TO BE REMOVED BACK TO
EXIST SHEATHING TO PREP AREA FOR
NEW CONSTRUCTION - REPAIR AS REQ'D
EPDM RUBBER ROOF FLASHED OVER MTL
DRIP EDGE AND UP NEW ROOFING
BLACK MTL CAP FLASHING OVER DOOR &
ALONG LENGTH OF HOUSE WHERE
LEDGER IS BOLTED TO HOUSE
DOOR TRIM TO BE REPLACED TO
MATCH EXISTING
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
AS NOTED
ELEVATIONS &
DETAILS
A-2
EXIST DECK TO
BE REMOVED IN
ITS ENTIRETY
7/25/2020
2020-20
12.
13.
14.
ELECTRICAL NOTES
1.
2.
3.
4.
7.
5.
6.
8.
9.
10.
11.
ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICIAN
ALL FIXTURES AND FINISHES ARE TO BE SUPPLIED BY OWNER & INSTALLED BY G.C.
U.O.N.
ALL MATERIAL USED SHALL BE NEW, BEST OF THEIR RESPECTIVE KINDS, FREE FROM
DEFECTS AND CONFORM TO THE REQUIREMENTS OF ALL LOCAL, STATE, AND NATIONAL
AUTHORITIES HAVING JURISDICTION.
SUBCONTRACTORS SHALL FILE FOR PLUMBING AND ELECTRICAL PERMITS, PAY FOR
ALL FEES AND HAVE THEIR WORK INSPECTED BY STATE AND LOCAL AUTHORITIES
HAVING JURISDICTION. CONTRACTOR SHALL SECURE ANY AND ALL CERTIFICATES OF
COMPLIANCE AND/OR INSPECTION ISSUED BY SAID AGENCIES. ANY MODIFICATION OR
CHANGE CALLED FOR BY AUTHORITIES HAVING JURISDICTION SHALL BE MADE
WITHOUT ADDITIONAL CHARGE.
ARCHITECTURAL DRAWINGS FOR PLUMBING AND ELECTRICAL ARE DIAGRAMMATIC
AND INDICATE THE GENERAL ARRANGEMENT OF THE WORK REQUIRED. EACH
CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES AS REQUIRED
TO AVOID INTERFERENCES AND INSURE PROPER INSTALLATION.
ALL SUBCONTRACTORS SHALL LAY OUT THEIR WORK IN ADVANCE SO ALL NECESSARY
ACCOMMODATIONS FOR IT CAN BE MADE AS REQUIRED. UNNECESSARY CUTTING OF
THE STRUCTURE IS TO BE AVOIDED. SHOULD A CONTRACTOR REQUIRE CUTTING FOR
THE INSTALLATION OF HIS WORK HE SHALL COORDINATE HIS REQUIREMENTS WITH
OTHER CONTRACTORS AND THE ARCHITECT AND PAY ALL COSTS FOR SAID CUTTING,
STRENGTHENING, AND ANY PATCHING THAT MAY RESULT.
ALL WORK SHALL BE INSTALLED READILY ACCESSIBLE FOR OPERATION,
MAINTENANCE, AND REPAIRS. EQUIPMENT INSTALLED AS A PART HEREOF IS TO BE
FULLY GUARANTEED FOR ONE (1) YEAR AGAINST FAULTY PARTS AND WORKMANSHIP
FROM THE DATE OF ACCEPTANCE OR FINAL PAYMENT, WHICHEVER COMES LATER.
ANY RIGGING AND HOISTING REQUIRED BY ANY CONTRACTOR SHALL BE DONE BY HIM
AS A NORMAL PART OF HIS INSTALLATION PROCEDURES.
ACCESSORIES NEEDED TO MAKE THE INSTALLATION OF EACH SUBCONTRACTOR
PERFECT AND COMPLETE IN ALL RESPECTS AND READY FOR OPERATION, EVEN IF
NOT PARTICULARLY CALLED FOR, SHALL BE FURNISHED, DELIVERED AND INSTALLED
HEREIN WITHOUT ADDITIONAL COST. INCLUDED HERE UNDER SHALL BE, BUT NOT
LIMITED TO, THE INCIDENTAL OR MINOR ITEMS THAT ARE NOT SHOWN OR SPECIFIED,
BUT WHICH ARE CONSIDERED AS NECESSARY FOR THE PROPER FUNCTIONING OF
THE INSTALLATION BY TRADE CUSTOM AND/OR STANDARD PRACTICE, OR SPECIAL
REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
WHERE OUTLETS AND SWITCHES ARE PLACE IN CABINETRY, PANELING OR MOLDING,
THE CARPENTER, NOT THE ELECTRICIAN, SHALL MAKE ALL CUTS.
UNLESS OTHERWISE NOTED, ALL WALL SWITCHES SHALL BE MOUNTED 3'-0" .FF.. TO
CENTER AND ALIGN WITH DOOR HARDWARE AT 3'-0" A.F.F.
ALL MULTI-GANG FACE PLATES SHALL BE ONE PIECE.
ALL MATERIAL, EQUIPMENT, AND FIXTURES, INCLUDING THOSE SUPPLIED BY OWNER
AND INSTALLED BY G.C., MUST BE IN COMPLIANCE WITH U.L.
PROPOSED PROJECT SHALL COMPLY WITH THE NEW YORK STATE BUILDING CODE FOR
RESIDENTIAL (2020 NYS RESIDENTIAL CODE, 2020 PLUMBING CODE OF NYS, NATIONAL
ELECTRIC CODE 2017 OF NYS)
REFLECTED CEILING NOTES
5.
6.
4.
1.
2.
THIS LIGHTING PLAN IS FOR REFERENCE ONLY ALL LIGHTING LOCATIONS AND FIXTURE
TYPES ARE TO BE BY THE HOME OWNER AND INSTALLED BY G.C. U.O.N
ALL NEW SWITCHES ARE TO NEW DECORA TYPE SWITCHES
COORDINATE THE TEL/ DATA / CABLE OUTLETS W/ OWNER
ALL NEW DOWNLIGHTS ARE TO BE EXTERIOR RATED
CONTRACTOR TO COORDINATE FINAL LOCATION & TYPE OF LIGHTING FIXTURES WITH
OWNER BEFORE INSTALLATION
3.
ALL NEW SWITCH LOCATIONS ARE TO BE CONFIRMED IN THE FIELD WITHT THE OWNER
15.
NO BEDROOMS ARE ADDED AS PART OF THIS DESIGN
Machine-extracted for search and reference — the original PDF is the authoritative version.