Agenda item: New Business — AC General Contractor, Inc.---167 Maple Street-Located in a RB 2-Family Residential District and designated on the Tax Maps of Croton-on-Hudson as Section 68.17 Block 4 Lot 37. Request for a rear yard variance from Village Zoning Code Section 230-34 for a proposed 2-story rear deck for a 2-family house.
Agreement / contract, 1 page. Attached to agenda item: “New Business — AC General Contractor, Inc.---167 Maple Street-Located in a RB 2-Family Residential District and designated on the Tax Maps of Croton-on-Hudson as Section 68.17 Block 4 Lot 37. Request for a rear yard vari”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
167 Maple 5 Factors Response 2024
167 Maple Application
167 Maple Drawings
167 Maple Proposed 2 story residence drawing
Extracted text
Inv. 94.5
Alarm & Lag on Elev. 92.75
Pump on Elev. 92.25
Pump off Elev. 90.75
Bottom
Elev. 89.75
4" C.I.
2" PVC SDR 21
Inv. 96.0
Alarm & Lag on
Elev. 92.75
Pump on
Elev. 92.25
Pump off
Elev. 90.75
Grd. 98.0
top 3" above finished grade
Inlet Invert Elev.
96.0
Alarm on Elev.
92.75
Elev. Difference
3.25 ft.
3.25ft x 211.5 gal/ft = 687 gal.
Req. Emergency Storage 660 gal.
687>660 gallons
Submersible Sewage Ejector Pump System:
Goulds/Xylem Model 3886, WS05B Series
Centipro Duplex Control Panel Nema 1 for
indoor mounting.
Three (3) float system. "ON"--"OFF"--"LAG &
ALARM"