06-23-2024-13551-Croton Auto Mall Electrical Set

application 7 pages
Meeting: portal event 971 (no meeting page on file)
Agenda item: New Business — Referral from Village Board of Trustees to review a Special Permit Application from Sprocket Power for an integrated energy system to be installed at Croton Auto Park at 1 Municipal Place (79.12-3-2)
Application, 7 pages. Attached to agenda item: “New Business — Referral from Village Board of Trustees to review a Special Permit Application from Sprocket Power for an integrated energy system to be installed at Croton Auto Park at 1 Municipal Place (79.12-3-2)”
Retrieved 2026-04-15 from the village's meeting portal. View the original PDF ↗
Also attached to this agenda item: 24-08 Site Plan 6-21-24 Auto Park Letter from Landlord Auto Park Solar Special Permit Application Cover Letter for Croton Board of Trustees Croton Auto Mall -survey July 17th Resolution 146-2024 1 Municipal Place... Planning Board Review of Special Permits
PANELBOARD AND CABINETS SURFACE TYPE PANELBOARD DISTRIBUTION PANELBOARD EXISTING TO BE DEMOLISHED AND REMOVED BRANCH CIRCUIT PROTECTIVE DEVICE. UNFUSED DISCONNECT SWITCH. RATING SAME AS UPSTREAM CONDUIT TURNING DOWN NUMBER OF POLES AS INDICATED. POWER CIRCUIT HOMERUN - CIRCUIT BREAKER SIZE AND FUSED DISCONNECT SWITCH MOTOR WITH JUNCTION BOX AND FLEXIBLE CONDUIT NUMERAL DENOTES HORSEPOWER. DENOTES SWITCH SIZE DENOTES FUSE SIZE IF INDICATED DENOTES SWITCH SIZE CONDUIT TURNING UP CONDUIT SYSTEM POWER UNDERGROUND CONDUIT RUN. CIRCUIT HOMERUN TO PANEL BOARD - ARROWS DENOTE NUMBER OF CIRCUITS. DESIGNATION DENOTES PANEL BOARD AND CIRCUIT NUMBERS. 'F' DENOTES FRACTIONAL HORSEPOWER LESS THAN 1/2 HP CONNECTION. 3#12,1#12G DP-3A #2 -ê"C. 'A' - 'B' - - 'A' #1,2,3 LP-3A EXISTING WORK NEW WORK ABBREVIATIONS ABBREVIATION DESCRIPTION AC ABOVE CENTER AFF ABOVE FINISHED FLOOR ATS AUTOMATIC TRANSFER SWITCH BFG BELOW FINISHED GRADE BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CL CLOSET CB CIRCUIT BREAKER CBV CABLE BY VENDOR CKT(S) CIRCUIT(S) DP DISTRIBUTION PANEL DISC DISCONNECT SWITCH EB CON EDISON END BOXES EC EMPTY CONDUIT ELEV ELEVATOR EM EMERGENCY ER EXISTING TO BE RELOCATED EWC ELECTRIC WATER COOLER EX/E EXISTING FA FIRE ALARM GRD/GND GROUND HD ELECTRIC HANDDRYER HC HUNG CEILING HP HORSE POWER IG ISOLATED GROUND LAN LOCAL AREA NETWORK LTG LIGHTING MTD MOUNTED NIC NOT IN CONTRACT NO NORTH OC ON CENTER P POLES(S) PB PULL BOX PC PERSONAL COMPUTER PH PHASE PM POWER MONITOR PNL PANEL RGS RIGID GALVANIZED STEEL SO SOUTH SP SPARE STD STANDARD SW SWITCH TBD TO BE DETERMINED TEL TELEPHONE TVSS TRANSITION VOLT SURGE SUPRESSION TYP TYPICAL UNF UNFUSED UON UNLESS OTHERWISE NOTED UTP UNSHIELDED TWISTED-PAIR V VOLT W WIRE WP WEATHERPROOF XFMR TRANSFORMER ELECTRICAL GENERAL NOTES: 1. BEFORE SUBMITTING A BID PROPOSAL, THE CONTRACTOR SHALL: A. VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH JOB CONDITIONS. B. REVIEW A FULL SET OF BID DOCUMENTS TO MAKE SELF AWARE OF THE TOTAL JOB BEFORE SUBMITTING A PRICE. C. VERIFY ALL EXISTING CONDITIONS IN THE FIELD AND INCLUDE IN BID PRICE ALL WORK REQUIRED TO ACCOMMODATE THE EXISTING INSTALLATION. 2. COORDINATE WITH OTHER TRADES TO DETERMINE THE EXACT LOCATION OF MOTORS, MOTOR TERMINAL BOXES, AND OTHER EQUIPMENT TO BE INSTALLED BY OTHER TRADES BEFORE CONDUIT WORK IS STARTED. REFER TO MECHANICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR LOCATIONS OF ALL EQUIPMENT. 3. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS OF FINISHED CONSTRUCTION PRIOR TO FABRICATION AND INSTALLATION OF FIXTURES AND EQUIPMENT. 4. EXISTING ELECTRICAL EQUIPMENT AND PANELBOARDS SHALL BE MODIFIED AS REQUIRED TO ACCOMMODATE THE WORK OF THIS CONTRACT. REPLACE EXISTING CIRCUIT BREAKERS IN PANELS WITH IDENTICAL NEW BREAKERS AS REQUIRED AND PROVIDE UPDATED DIRECTORIES. 5. EXISTING EQUIPMENT AFFECTED BY THE WORK OF THIS CONTRACT SHALL BE COMPLETELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS OF THIS CONTRACT. 6. ANY EXISTING WORK DAMAGED AS A RESULT OF PERFORMING THE WORK OF THIS CONTRACT SHALL BE REPAIRED OR REPLACED AS REQUIRED. MATERIAL AND FINISH TO MATCH EXISTING TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. 7. ALL WORK REQUIRING ELECTRICAL SHUTDOWN WHICH WILL AFFECT OTHER FLOORS OF THE BUILDING OR EVEN AFFECT THE NORMAL CONTINUATION OF CONSTRUCTION WORK ON THESE FLOORS, SHALL BE DONE ON OVERTIME HOURS, AND SHALL NOT DISTURB CONTINUITY OF ELECTRICAL SERVICE TO EXISTING TENANTS ON THE AFFECTED FLOORS. 8. ALL ELECTRICAL WORK IN ADJOINING AREAS WHICH IS REQUIRED TO FUNCTION BUT IS AFFECTED BY THIS WORK SHALL BE RECONNECTED AND RESTORED TO ITS PRESENT FUNCTION AS PART OF THE ELECTRICAL SYSTEM OF THE BUILDING(S). 9. MOUNTING HEIGHTS OF EQUIPMENT AND DEVICES SHALL BE AS INDICATED ON THE ARCHITECTURAL DRAWINGS. WHERE MOUNTING HEIGHTS ARE NOT GIVEN ON THE ARCHITECTURAL DRAWINGS, UTILIZE THE FOLLOWING MOUNTING HEIGHTS UNLESS OTHERWISE NOTED (ALL DIMENSIONS TO CENTERLINE OF BOX): 10. WHERE CONDUIT AND WIRING CONNECTIONS ARE NOT SHOWN ON THE PLANS, MAKE CONNECTIONS AS FOLLOWS: A. USE #10 AWG WIRE TO THE FIRST AND ANY OUTLET FOR BRANCH CIRCUIT RUNS MORE THAN 80 FEET FOR 120V AND 208V CIRCUITS, U.O.N. B. USE #10 AWG WIRE TO THE FIRST AND ANY OUTLET FOR BRANCH CIRCUIT RUNS MORE THAN 150 FEET FOR 265V AND 460V CIRCUITS, U.O.N. 11. ALL BRANCH CIRCUIT WIRING SHALL BE RUN CONCEALED IN WALLS AND/OR ABOVE HUNG CEILING UNLESS OTHERWISE NOTED. 12. WIRING IN AIR PLENUM HUNG CEILINGS INSTALLED WITHOUT CONDUIT OR EMT SHALL BE TEFLON JACKETED. 13. NO LOW VOLTAGE WIRING SHALL BE PERMITTED IN THE SAME RACEWAY AS POWER WIRING. 14. CONTRACTOR TO DE-RATE CONDUCTORS IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE WHEN INSTALLING MORE THAN THREE (3) CIRCUITS IN A 3/4"C HOMERUN. 15. PROVIDE DRAG LINES IN ALL EMPTY RACEWAYS. ALL DRAG LINES SHALL BE TAGGED AND LABELED AT BOTH ENDS. 16. ALL CONDUITS FOR BRANCH CIRCUITING AND/OR COMMUNICATIONS CABLING, INCLUDING THOSE RUN IN CEILING OF FLOOR BELOW SHALL BE IDENTIFIED AT EVERY 50 FEET OF LENGTH AND AT EACH OUTLET AND PULL BOX WITH PANEL AND CIRCUIT NUMBER OR SYSTEM NAME. Y TRANSFORMER ELECTRICAL, SYMBOLS, ABBREVIATIONS, & NOTES WP PC E-001 DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 NOTES: 1. FOR SYMBOL LIST AND GENERAL NOTES REFER TO DRAWING E-001. 2. FOR ADDITIONAL INFORMATION REFER TO ELECTRICAL 3-LINE DIAGRAM DRAWING E-501 3. CONDUIT ROUTING IS SHOWN FOR CLARIFICATION ONLY, CONTRACTOR SHALL COORDINATE THE EXACT ROUTING IN FIELD. 4. REFER TO DRAWING E-701 FOR DUCT BANK SECTION DETAIL KEY NOTES: COORDINATE WITH CON EDISON TO DISCONNECT AND REMOVE EXISTING SERVICE FEEDER TO THE BUILDING. RETAIN EXISTING CONDUIT FOR REUSE. DISCONNECT AND REMOVE EXISTING CTS AND UTILITY METER, COORDINATE WITH CON EDISON AS REQUIRED. REPURPOSED EXISTING CT CABINET TO BE USE AS A SPLICE BOX REMOVE THE EXISTING NEUTRAL TO GROUND BONDING AT EXISTING SERVICE EQUIPMENT. INTERCEPT THE EXISTING 4" CONDUIT FROM THE BUILDING AND EXTEND CONDUIT TO THE 600A PANEL PROVIDE NEW FEEDEER FROM THE 600A PANEL VIA THE REPURPOSED CT CABAINET TO SERVICE EXISTING EQUIPMENT IN THE BUILDING. 1369.8621 2667.3941 1284.2944 2629.5055 1215.0404 2539.3696 1231.5613 2531.1352 1470.6342 2216.1682 1498.0329 2181.4997 1578.8016 2469.8642 1525.9125 2487.2703 1464.9973 2480.9974 1502.4662 2416.0266 1510.2814 2439.7733 1632.6878 2460.0291 1564.1829 2474.6752 1517.2951 2492.1763 1476.9475 2529.5483 1387.6683 2664.7595 1266.0166 2605.7164 1277.5109 2470.5989 1368.2007 2351.1194 1424.1159 2277.4539 1510.8172 2501.0108 1445.6039 2527.0832 1422.6315 2507.5518 1415.0740 2478.2285 1435.1183 2440.9069 1489.9763 2437.6840 1563.1710 2422.3701 1354.7143 2108.5096 1354.3264 2124.2589 1546.4101 2342.9894 M S72°30'00"E 145.46' N26°00'00"E 110.00' N64°00'00"W 64.00' N64°00'00"W 71.73' S26°00'00"W 110.00' N26°15'45"W 131.13' S17°30'00"W 35.14' S17°30'00"W 55.00' S17°30'00"W 55.00' S17°30'00"W 89 N08°25'00"W 64.86' S46°20'25"W 163.69' S66°12'10"W 119.54' W 37.51' N08°25'00"W 55.00' N81°35'00"E 110 S48°23'50"W 110.13' N53°49'40"W 82.99' 1439.2299 2657.1341 1384.8222 2665.1844 1160.5633 2698.3668 988.1283 2783.4491 1193.1402 2797.6240 1010.2525 2828.2879 1165.0845 2855.1468 995.2172 2875.9737 1028.7308 2886.5405 1081.1853 2903.0794 1133.6397 2919.6182 1295.7446 2838.7667 1197.9374 2791.0629 1242.1206 2730.6328 1295.757 2838.7778 LOT 24 LOT 23 LOT 22 LOT 21 N 38° 19' 00" E 148.24' S 88° 35' 20" E 15.75' 838.3610 2615.7329 854.7084 2382.0316 N 26° 29' 34" W 456.45' N 75° 58' 14" W 131.14' N 85° 59' 14" W 234.30' N 27° 51' 14" W 192.60' N 41° 43' 14" W 341.79' S 88° 35' 20" E 15.75' N 38° 19' 00" E 148.24' N 52° 48' 00" W 395.42' N 75° 58' 14" W 40.51' N 26° 29' 34" W 456.45' N 26° 29' 34" W 18.46' S 52° 27' 50" W 113.67' N 65° 41' 00" E 52.00' N 40° 12' 40" W 83.22' N 53° 49' 40" W 82.99' N 64° 00' 00" W 64.00' N 64° 00' 00" W 71.73' S 17° 30' 00" W 55.00' S 17° 30' 00" W 55.00' S 17° 30' 00" W 212.41' S 5 49.99' 25 Ft. Wide Sanitary Sewer and Storm Drain Easement S 28° 11' 10" W 233.02' Survey N 28° 11' 10" E 276.41' S 41° 43' 14" E 45.36' S 57° 10' 00" W 36.33' 25.30' 76.94' 25.00' [229.51' Deed] S 52° 48' 00" E 395.44' N 75° 58' 14" W 131.14' N 85° 59' 14" W 234.30' N 27° 51' 14" W 192.60' N 41° 43' 14" W 341.79' R=89.06' L=90.40' =58° 09' 53" S 88° 35' 20" E 15.75' N 38° 19' 00" E 148.24' S 26° 29' 34" E 474.91' 1024.9942 2292.0453 1280.1061 2064.5846 1199.0340 2136.8695 1218.7284 2167.3902 1165.1773 2167.0565 1408.8119 2297.6162 1356.8975 2019.4764 806.5213 2742.9854 719.1300 2587.3164 729.0060 2434.4351 BL-Crosscut W O S D Y H W O S W O S W O S BL-Crosscut BL-Crosscut BL-Spike BL-Crosscut BL-Crosscut BL-Crosscut BL-Crosscut 3500 PIN FOUND PIPE FOUND GUY WIRE WOOD GUIDE POLE METAL GUARD RAIL EDGE OF PAVEMENT OVERHEAD SERVICES WIRES ASPHALT PARKING AREA CONCRETE APRON COVERED ROOF Metal Storage Container (Moveable) L E D G E R O C K NO PHYSICAL BOUNDS NO PHYSICAL BOUNDS CONCRETE APRON SIGN HIGH ONE STORY STUCCO AND CONCRETE BLOCK BUILDING Roof Line Pier LIGHT POLE DRAIN DRAIN LIGHT LIGHT DRAIN GUY WIRE WIRE DROP CURB TRAFFIC POLE CROSSWALK POLE GUY GUY WIRE OVERHEAD SERVICE WIRES METAL GUARD RAIL METAL GUARD RAIL METAL GUARD RAIL T T T ASPHALT PARKING AREA CONCRETE APRON Roof Line Pier Conc.Base PIN FOUND ASPHALT PARKING AREA ASPHALT PARKING AREA GRAVEL AREA DRAIN DRAIN CONCRETE APRON Garage Bay Garage Bays Garage Bay Garage Bays ONE STORY CONCRETE PAD DRAIN INLET SIGN Island Grass REMAINS OF STOCKADE FENCE UTILITY POLE WITH LIGHTS UTILITY POLE WITH LIGHTS UTILITY POLE WITH LIGHTS Pier Pier SIGN SIGN FLAG POLE COVER METAL TRAFFIC SIGN COVER METAL CONC PAD SIGN LIGHT LIGHT N 49° 00' 09" W 67.21' S 82° 25' 09" W 249.70' N 39° 32' 52" W 396.49' S 83° 20' 19" E 331.49' S 38° 29' 48" E 355.75' N 73° 26' 35" E 401.73' Pier Pier Pier Pier CONC. RET. WALL CONCRETE SIDEWALK Conc Ramp DRAIN Pier Gas Meter Gas Markings on Pavement UTILITY POLE / LIGHT UTILITY POLE UTILITY POLE UTILITY POLE UTILITY POLE / LIGHT GUY WIRE UTILITY POLE / LIGHT UTILITY POLE CATCH BASIN DRAIN 16.4' DRAIN Conc Pad GUY WIRE Metal Anchor Metal Anchor 40.4' 10.5'± 17'± 17.5'± OVERHEAD SERVICE WIRES 1.44' To Corner UTILITY OVERHEAD PRIMARY LINE TO BE DEMOLISHED BY CON EDISON 1-4"C 400APNL 1 -3"C DCFC (L3) 1-2" CONTROLS GROUNDING BUS BAR EXISTING INCOMING DOMESTIC WATER SUPPLY GROUND BOND TO DOMESTIC SUPPLY 1-2 1/2" CAP 19.2KW L2 WALL MOUNTED EV CHARGERS 24'x20' CANOPY MOUNTED PV PANELS NEW UTILITY POLE CLASS 5 CUSTOMER POLE 2-2"C NEW UNDERGROUND PRIMARY SEE NOTE 4 PRIMARY OVERHEAD 1#1/0-1"C CT EV1 EV2 CLEARANCE AREA EMPTY 2 1/2" CONDUIT ELECTRICAL SITE PLAN WCP PC E-002 DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 E-002 SCALE: 1/32"=1'-0" 64 FEET SITE ELECTRIC SERVICE POWER PLAN E-401 E-401 64 FEET PADMOUNT TRANSFORMER & VAULT 800A MAIN DISCONNECT CON ED METER COMBINER PANEL 480V,800A 3Ø,4W BESS 600A PANEL 1-4" C EXISTING NEW UTILITY POLE UTILITY OVERHEAD PRIMARY LINE TO BE DEMOLISHED BY CON EDISON CLASS 5 CUSTOMER POLE SAFETY BOLLARDS BY OTHER (TYP) MIN. 42" WORKING CLEARANCE CLEARANCE AREA BESS DISCONNECT 28"X 11" 7' TALL FENCE 6'-7' SPRUCE EVERGREEN TREES 150KVA STEP DOWN TRANSFOMER NEW UNDERGROUND PRIMARY W O S D Y H RAIL PARKING AREA APRON O LIGHT NOTES: 1. FOR SYMBOL LIST AND GENERAL NOTES REFER TO DRAWING E-001. 2. FOR ADDITIONAL INFORMATION REFER TO ELECTRICAL 3-LINE DIAGRAM DRAWING E-501 3. CONTRACTOR SHALL PROVIDE STAINLESS C CHANNEL MOUNTING RACKS FOR THE FOR THE INSTALLATION OF THE DISCONNECT SWITCHES, METER CABINET, PANELS ETC. 4. BOLLARD, CONCRETE, PADS, TREES AND FENCE ARE SHOWN FOR COORDINATION ONLY, REFER TO THE CIVIL ENGINEERING DRAWING FOR ADDITIONAL INFORMATION. KEY NOTES: COORDINATE WITH CON EDISON TO DISCONNECT AND REMOVE EXISTING SERVICE FEEDER TO THE BUILDING. RETAIN EXISTING CONDUIT FOR REUSE. PROVIDE APPROVED SIGNAGE AS PER APPLICABLE CODES AND STANDARD. SIGNAGE SHALL READ AS FOLLOWS: --- ESS TYPE: BATTERY STORAGE SYSTEM --- LITHIUM IRON PHOSPHATE; CAPACITY 280KWH --- ENERGIZED ELECTRICAL CIRCUITS: MAIN COMBINER SWITCHBOARD. --- DO NOT APPLY WATER --- FIRE MITIGATION PERSONNEL TEL #: XXX-XXX-XXX SAFETY BOLLARDS ARE SHOWN ON THE ELECTRICAL DRAWING FOR REFERENCE ONLY. THE CONTRACTOR SHALL REFER TO STRUCTURAL ENGINEER DRAWINGS FOR TYPE, SIZE QUANTITY AND PERTINENT INFORMATION INTERCEPT THE EXISTING 4" CONDUIT FROM THE BUILDING AND EXTEND CONDUIT TO THE 600A PANEL PROVIDE NEW FEEDER FROM THE 600A PANEL VIA THE RE-PURPOSED CT CABINET TO SERVICE EXISTING EQUIPMENT IN THE BUILDING. CONCRETE PAD BY OTHER; CONCRETE MIINIMUM STRENGTH 4000 PSI SLAB THICKNESS 8" 1-4" C 400A PNL 1-3"C DCFC(L3) 1-2" CONTROLS 180 KW DCFC CHARGER 2-2" C SAFETY BOLLARDS BY OHTER (TYP) 12 KW INVERTER EV PARKING SPACES 24' X 20' PV MODULE 48 X 36" CHARGER CONRETE PAD 60A NEMA-3R INVERTER DISCONNECT DCFC CHARGER DISCONNECT EV1 EV2 WORKING CLEARANCES CANOPY PNL NEMA 3R 400A 60A NEMA-3R INVERTER DISCONNECT SITE ELECTRICAL SERVICE POWER PART PLAN, EV CHARGE STATION POWER PART PLAN WCP PC E-401 DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 E-401 16 FEET SCALE: 1/8"=1'-0" SITE ELECTRIC SERVICE EQUIPMENT POWER PART PLAN E-401 16 FEET SCALE: 1/8"=1'-0" EV CHARGE STATION POWER PART PLAN PADMOUNT TRANSFORMER & VAULT CON ED METER COMBINER PANEL 480V,800A 3Ø,4W BESS 600A PANEL 1-4" C EXISTING NEW UTILITY POLE UTILITY OVERHEAD PRIMARY LINE TO BE DEMOLISHED BY CON EDISON CLASS 5 CUSTOMER POLE SAFETY BOLLARDS BY OTHER (TYP) MIN. 42" WORKING CLEARANCE CT CLEARANCE AREA BESS DISCONNECT 28"X 11" 7' TALL FENCE 6'-7' SPRUCE EVERGREEN TREES 150KVA STEP DOWN TRANSFOMER NEW UNDERGROUND PRIMARY W O S D Y H RAIL PARKING AREA APRON ONE S CON PAD LIGHT Pier 40.4' 800A MAIN DISCONNECT CROTON AUTO PARK - 1 MUNICIPAL PLAZA 4. 800A CON ED METER 1. 150 KVA TRANSFORMER 2. BATTERY STORAGE SYSTEM 3. PAD MOUNTED UTILITY TRANSFORMER 5. 800A MAIN DISCONNECT SWITCH 6. COMBINER PANEL 7. 600A PANEL EQUIPMENT DIMENSIONS W, D, H PHOTO # 800A COMBINER PANEL 93.5" x 88.5" x 49.21" #6 150KVA TRANSFOMER 44.5" x 31.5" x 29.5" #1 BATTERY STORAGE SYSTEM 92.13" x 51.18" x 51.18" #2 800A SERVICE SWITCH 48" x 36.62" x 17.75 " #5 800A METERING CABINET 48" x 24" x 10" #4 600A PANEL 36" x 30" x 90" #7 UTILITY TRANSFORMER 71" x 63" x 61" #3 SITE ELECTRICAL SERVICE EQUIPMENT WCP PC E-402 DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 E-402 16 FEET SCALE: 1/8"=1'-0" SITE ELECTRIC SERVICE EQUIPMENT POWER PART PLAN E-402 ELECTRIC SERVICE EQUIPMENT N.T.S EQUIPMENT SPECIFICATION SHEET WCP PC E-403 DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 E-403 B.E.S.S E-403 PV INVERTERS E-403 PV PANEL NOT FOR CONSTRUCTION ZEVORA DC FAST CHARGER DS-180 SERIES 180 KW AC POWER 232A MAX OUTPUT 480VAC / 3Φ4W 300A/3P 200A/3P/LSIG G X0 X3 X2 X1 TRANSFORMER 150KVA / NEMA 3R 480V DELTA PRIMARY 208Y/120V SECONDARY H3 H2 H1 A B NG 225A/3P LSI 13.2 KV CON EDISON OVERHEAD NETWORK PAD MOUNTED CON EDISON TRANSFORMER CABLE SCHEUDLE CALLOUT ID WIRE SIZE PARALLEL RUNS PHASE SIZE NEUTRAL SIZE GROUND SIZE & TYPE INSULATION CONDUIT TYPE A 2Φ PER STRING, G 1 PER STRING #10 AWG CU - #6 AWG CU EGC 2KV PVWIRE VARIES* B 3Φ, N, G #350 KCMIL CU #350 KCMIL CU #2 AWG CU EGC 600V THWN2 3" C C 3Φ,G #4/0 AWG CU - #6 AWG CU EGC 600V THWN2 2 1/2" C D 3Φ, N, G #3/0 AWG CU #3/0 AWG CU #6 AWG CU EGC 600V THWN2 2 1/2" C E 3Φ,N,G #500 AWG CU #500 AWG CU #2/0 AWG CU EA 600V THWN2 4" C F 3Φ, N, G #8 AWG CU #8 AWG CU #12 AWG CU SSBJ 600V THWN2 1" C G 1Φ, N, G #12 AWG CU #12 AWG CU #12 AWG CU EGC 600V THWN2 1 1/4" C H 3Φ, N, G #350 KCMIL CU #350 KCMIL CU #2 AWG CU SSBJ 600V THWN2 3" C J 2Φ,N,G #2 AWG CU #2 AWG CU #8 AWG CU EGC 600V THWN2 1. 1/2" C K 3Φ, N, G #3/0 AWG CU #3/0 AWG CU #6 AWG CU 600V THWN2 2" C L 3Φ, N #500 KCMIL CU #500 KCMIL CU #1/0 AWG CU EA 600V THWN2 4" C N 1 CABLE RS485 - - BELDEN 3106A 1" C O 3PH, N, G #8 AWG CU #10 AWG #10AWG 600V THWN2 3/4" C C SEL 751 25, 27, 32, 50, 50N, 51, 51N, 51V, 59, 81O, 81U, 86 480:120 V 1.5KVA UPS 40A/3P 20A/1P *MOTOR OPERATED SHUNT TRIP, COMM, POWER ELECTRONIC TRIP 52-IT4 BESS DISCONNECT EV DISCONNECT *52-IT GF 800/3P LSIG LOCATED ON OUTSIDE PARKING AREA BY UTILITY POLE X2 X3 X1 H2 H3 H1 H0 X0 X3 MAIN SERVICE DISCONNECT SWITCH LEGEND SYNC CHECK RELAY UNDERVOLTAGE RELAY REVERSE POWER/OVERLOAD RELAY LOSS OF EXCITATION RELAY INSTANTANEOUS OVERCURRENT RELAY NEUTRAL INSTANTANEOUS OVERCURRENT RE;LAY 50N TIME OVERCURRENT RELAY NEUTRAL TIME OVERCURRENT RELAY 51N VOLTAG-RESTRAINED TIME OVERCURRENT RELAY 51V OVERVOLTAGE RELAY OVERVOLTAGE RELAY DIRECTIONAL OVERCURENT RELAY OVER FREQUENCY RELAY 81U UNDER FREQUENCY RELAY LOCKOUT RELAY POWER MONITORING SYSTEM CURRENT & VOLTAGE SENSING DEVICE EOFM ELECTRICALLY OPERATED FIXED MOUNT ESS ENERGY STORAGE SYSTEM SPD SURGE SUPPRESSOR VOLTAGE 89S LINE SWITCH 89L LOAD MAKING/BREAKING PAD LOCKABLE SWITCH ENERGY MANAGEMENT SYSTEM EMERGENCY STOP PUSH BUTTON GROUNDING CONNECTION TRANSFORMER CIRCUIT BREAKER MOTOR OPERATED GROUND FAULT CLASS 0.5 CURRENT TRANSFOMER CURRENT TRANSFORMER (CT) POTENTIAL TRANSFORMER (PT) HEAVY LINE TYPE REPRESENTING NEW ELECTRICAL SYSTEM ELEMENT (EQUIPMENT, DEVICE FEEDER, ETC.) LIGHT LINE TYPE REPRESENTING EXISTING ELECTRICAL SYSTEM ELEMENT (EQUIPMENT, DEVICE FEEDER, ETC.) DASHED LINE TYPE REPRESENTING CONTROL WIRING IN 1"C ELECTRONIC SUBMETER UTILITY METER PMS I35 EMS PB METER M 24VDC BATTERY CHARGER AND BATTARY 100A/3P SPARE 13.2 KV/480V-277V L . C . H . B . D . NOTES: 1. ELECTRICAL INSTALLATION SHALL COMPLY WITH THE LATEST REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC) AND LOCAL SAFETY CODES AND REGULATIONS, INCLUDING CON EDISON. 2. REFER TO CON EDISON'S REQUIREMENTS FOR ALL INVERTER SETTINGS, INCLUDING STANDARD IEEE 1547-2018 / 1547a -2020 SETTINGS. 3. REFER TO BESS AND PV SOLAR SPECIFICATIONS, WIRING DIAGRAMS AND DETAILS FOR ADDITIONAL INFORMATION. 4. REFER TO SEQUENCE OF OPERATIONS FOR NORMAL, EMERGENCY AND ISLANDING MODE. 5. ALL SYSTEMS SHALL BE CONTROLLED BY KEYSTONE BESS ENERGY CONTROLS SYSTEM. 6. CIRCUIT BREAKER TRIP SETTINGS SHALL BE PROVIDED BY RELAYS SETTING REPORT. 7. PROVIDE SEPARATELY DERIVED GROUNDING SYSTEM PER CODE. REFER TO DRAWING E-701 FOR ADDITIONAL INFORMATION 8. DISCONNECT SWITCH SHALL BE VISIBLE BREAK, LEVER SWITCH WITH ACCESSIBLE DOOR 9. DISCONNECT AND REMOVE EXISTING CTS AND UTILITY METER. COORDINATE WITH CON EDISON. REMOVE THE EXISTING NUETRAL TO GROUND BONDING AT EXISTING SERVICE EQUIPMENT. RETAIN EXISTING CT CABINET TO BE USED AS A PULLBOX POWER SUPPLY 24VDC M SPD 52-IT COMBINER PANELBOARD 1,200A NEMA 3R / 65KAIC 480Y / 277V / 3Φ4W 800A MAIN CIRCUIT BREAKER SERVICE ENTRANCE RATED NEMA 3R KEYSTONE MICROGRID CONTROL PANEL UL9540, UL9540A & FORTRESS POWER ESPIRE 125KW/279.5KWH RATED CONT. CURRENT: 151A UL1741SB LISTED METER - ~ EMS N G 80A/3P A B C N G BATTERY STORAGE SYSTEM PANELBOARD 600A / NEMA 3R / 35KAIC 208/120V, 3Φ, 4W 600A/3P AUXILIARY POWER TO BESS(HEATING / COOLING), 208V, 3 PHASE. 40A/3P O A B C N G DC FAST CHARGER 300A/3P 200A/3P LSI EXISTING PANELBOARD 400A/208V K . SPARE O G LOCKABLE BESS 200A DISC 80A/3P LSIG N CT 800 AMPS 480V-277V, 3Ø, 4W CT CABINET NEMA 3R LOCATED ON FIRST FLOOR EXTERIOR WALL 800:5 800A 800A 89-L-1 MAIN SERVICE DISCONNECT SWITCH 480V-277V, 3Ø, 4W L . CON ED NET METER L . SEE NOTE #6 SEE NOTE #7 INVERTER SETTINGS SETTINGS PICKUP TIME (S) 27-1 80% V L-L 3.0 27-2 V L-L 1.1 59-1 V L-L 2.0 59-2 V L-L 2.0 81-O1 61.0 Hz 81-O2 62.0 Hz 0.16 81-U1 58.5 Hz 81-U2 56.5 Hz 0.16 INVERTER VOLTAGE: 600V L-L UTILITY INTERACTIVE INVERTER FUNCTION STATUS FUNCTION DEFAULT POWER FACTOR 1.0 VOLT-VAR OFF 2% MAX CURRENT OUTPUT PER SEC SOFT START RAMP RATE ON FREQ-WATT FUNCTION OFF 0.8 pu 0.5 pu 1.1 pu 1.2 pu 50% 110% 120% 480:120 V CT 800:5 A B NG C E PANELBOARD 400A/NEMA 3R/35KAIC 208/120V, 3Φ, 4W 89-L-3 PV LOCKABLE DISCONNECT 60A/3P F - ~ N G MPPT POS NEG A . 20A/1P CANOPY LIGHT & RECEPTACLE G 100A/2P EV CHARGER 01 ZEROVA AX80 16.64KW AC POWER 80A MAX OUTPUT 208VAC / 1Φ2W J 100A/2P EV CHARGER 02 ZEROVA AX80 16.64KW AC POWER 80A MAX OUTPUT 208VAC / 1Φ2W J A B NG C PV DISCONNECT 35A/3P LSIG 80A/2P 80A/2P SPARE SPARE 60A/3P F - ~ N G MPPT POS NEG A . STRINGS TO SOLAR MODS SOLAR PV ROOF INVERTER 2 SHENZHEN GSL ENERGY SE 10KHB-UL UL1741SB 208VAC/ 3Φ,4W PV DISCONNECT 35A/3P LSIG STRINGS TO SOLAR MODS UTILITY OVERHEAD PRIMARY LINE TO BE DEMOLISHED BY CON EDISION SEE NOTE #9 M SPARE 80A/3P LSIG NEMA 3R DCFC CHARGER DISCONNECT 400A/3P NEMA 3R BESS 89-L2 DISCONNECT 200A/3P 89-L-4 PV LOCKABLE DISCONNECT SOLAR PV ROOF INVERTER 1 SHENZHEN GSL ENERGY SE 10KHB-UL UL1741SB 208VAC/ 3Φ,4W DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 ELECTRICAL THREE LINE DIAGRAM NTS WCP PC E-501 RACEWAY EQUIPMENT GROUNDING SYSTEM (N.T.S) ROOF GROUNDING RISER DIAGRAM (N.T.S.) 1 #1/0-2"C 1#1/0-2"C WATER PIPE. (SEE GROUNDING DETAIL BELOW) XFMR 1#1/0-2"C EXTERIOR SERVICE AREA 1#1/0-2"C GAS & WATER SERVICE ROOM MAIN BUILDING GROUNDING BUS BAR BRANCH CIRCUIT CONDUIT FEEDER CONDUIT SERVICE ENTRANCE EQUIPMENT ENCLOSURE LIGHTING/POWER PANELBOARD GROUNDING BRUSHING DISTRIBUTION PANELBOARD GROUND LUG SYSTEM GROUNDING ELECTRODE CONDUCTOR (BUILDING GROUND) CONDUIT WITH GROUND CONDUCTOR. SEE ELECTRIC SERVICE GROUNDING SCHEMATIC ON THIS DRAWING FOR CONDUIT AND CONDUCTOR SIZE. SEE NOTE 1 MAIN BUILDING GROUNDING BUS BAR VALVES BACK FLOW PREVENTION DEVICE TO DISTRIBUTION PIPE TYPE GROUND CLAMP. SEE NO.2 PLASTIC CABLE TIES, 3/8" WIDE MINIMUM (TYP) PIPE TYPE GROUND CLAMP. SEE NOTE 3 EXIST. WATER MAIN FROM STREET BUILDING WALL EXIST. DOMESTIC WATER SERVICE. SEE WATER SERVICE GROUNDING DETAIL BELOW, SEE NOTE NO. 1 CONDUIT GROUNDING FITTING. SEE NOTE NO. 3 ELECTRIC SERVICE GROUNDING SCHEMATIC SCALE: NONE MAIN BOND TO JUMPER BOND TO ENCLOSURE SP 2 12 15" MIN. 12" RED VINYL MARKER STRIP WITH MAGNETIC BACKING GRADE REBAR (TYPICAL) 3" 3" 3" 3" SECTION A-A: DUCT DETAIL N.T.S. KEY NOTE: PVC SCHEDULE 40 CONDUIT (TYP.) POURED IN PLACE CONCRETE 36" MINIMUM BELOW GRADE PROVIDE PVC DUCT SPACER EVERY 6 1/2' - 7' NOTE: 1. INSTALLATION DEPTH TO BE DETERMINED IN FIELD TO AVOID INTERFERENCE WITH OTHER UNDERGROUND UTILITIES AND STRUCTURAL MEMBERS (36" MIN.). GROUNDING DETAIL-WATER/FIRE/STAND PIPE SERVICE SCALE:NONE NOTES: 1. TERMINATE CONDUIT NEAR WATER MAIN WITH A THREADED, CAST-BRONZE GROUND CLAMP, WITH A BRASS CONDUCTOR SET SCREW, CLAMP SHALL BE O-Z/GEDNEY TYPE GH-B SERIES OR APPROVED EQUAL. 2. GROUNDING CLAMP SHALL BE UL LISTED CONSISTING OF A COPPER GROUND CONNECTOR. A U-BOLT AND A CONDUCTOR CLAMP TO SECURE THE GROUND CONDUCTOR. CLAMP SHALL B EO-Z/GEDNEY TYPE GAR SERVICES 3. GROUND CONDUCTOR SHALL BE CONTINUOUS TO THE SECOND GROUND CLAMP ON THE OPPOSITE SIDE OF REMOVABLE EQUIPMENT, SUCH AS METERS, VALVES ETC., AS REQUIRED BY ARTICLE 250.68(B) OF NFPA 70 4. SECURE CABLE TO PIPE WITH 3/8" WIDE NYLON CABLE TIES. LEAVE ADEQUATE SLACK IN CABLE TO ALLOW EQUIPMENT TO BE REMOVED WITHOUT DISCONNECTING CABLE 5. GROUNDING AT FIRE PROTECTION SERVICES SHALL BE INSTALLED IN A SIMILAR MANNER NOTES: 1. WHERE THE BUILDING HAS MORE THAN ONE DOMESTIC WATER AND/OR FIRE PROTECTION SERVICE A GROUND CONDUCTOR, IN CONDUIT, SHALL BE INSTALLED FROM THE MAIN BUILDING GROUND BUS TO EACH DOMESTIC WATER AND FIRE PROTECTION SERVICE. COORDINATE WITH BUILDING ENGINEER FOR INSTALLATION. 2. NOT USED 3. CONDUIT GROUNDING FITTINGS SHALL BE O-Z/GEDNEY TYPE GH-B OR APPROVED EQUAL 4. GROUND BUS SHALL BE MINIMUM 1/4" x 4" x 30", DRILLED FOR TWO-HOLE HYDRAULIC COMPRESSION LUGS. TERMINATION OF GROUNDING ELECTRODE CONDUCTORS SHALL BE WITH TWO-HOLE COMPRESSION LUGS OR EXOTHERMIC WELD. PROVIDE TWO COPPER ALLOY MECHANICAL LUGS FOR FIRE ALARM GROUNDS, EQUAL TO FCI BURNDY TYPE "KA4C", OR APPROVED EQUAL, SECURED TO BUS WITH 1/4"-20 SILICON BRONZE BOLTS 5. GROUNDING ELECTRODE CONDUCTORS (TO WATER SERVICE, SUPPLEMENTAL ELECTRODE, BUILDING STEEL AND SERVICE SWITCH SHALL BE SIZED AS INDICATED. 6. WHERE GROUNDING CONDUITS TERMINATE AT AN ENCLOSURE , TERMINATE CONDUIT WITH LOCKNUTS AND A BONDING BUSHING 7. ALL GROUND CONDUCTOR TERMINATIONS AT GROUND BUS SHALL BE TWO HOLE HYDRAULIC COMPRESSION LUGS. LUGS SHALL BE SECURED TO BUS WITH SILICON BRONZE BOLTS, NUTS AND WASHERS. EACH BOLT SHALL BE PROVIDED WITH A SPRING STEEL BELLEVILLE WASHER AND SHALL BE TIGHTENED WITH A CALIBRATED TORQUE WRENCH. 8. TERMINATE CONDUIT AT GROUND BUS AND WATER MAINS WITH DIE0-CAST BRONZE FITTING BRASS SCREW. FITTING SHALL BE O-Z/GEDNEY GH-B SERIES SUPPLEMENTAL GROUNDING ELECTRODE SERVICE DISCONNECT GROUND BUS IN WATER METER ROOM 1#1/0-2"C MAIN SERVICE SWITCH 1#1/0-1"C 7.5" 7.5" 7.5" 7.5" THROUGH FIRE RATED WALL AND FLOOR DETAIL OF CONDUIT PENETRATING AND SLEEVE TO BE PACKED WITH UL/FM APPROVED MATERIAL AND TESTED TO THE REQUIREMENTS OF ASTM E814 (UL 1479) AND TO COMPLETELY COVER OPENING FLUSH AGAINST WALL AND OF SIZE FINISHED ESCUTCHEON PLATE ANNULAR SPACE BETWEEN PIPE STANDARD WEIGHT STEEL PIPE SLEEVE OF SIZE TO PASS PIPE FINISHED WALL SURFACE. PIPING EXPOSED TO VIEW (TYP FOR EACH SIDE). ASTM 119 (UL 263). FLUSH WITH FINISHED 1/2" CLEAR MAXIMUM WALL SURFACES CONCEALED PIPING SEAL OR CAULK SLEEVES THROUGH FIRE WALLS IN A SMOKE TIGHT MANNER. TERMINATE SLEEVE 7.5" DRAWING TITLE: GRAPHIC SCALE: SEAL: CHECKED: DRAWN: SHEET NUMBER: DATE: LORING JOB No.: APPROVED: REV.# DATE ISSUE DESCRIPTION CLIENT PROJECT No. KEY PLAN: CROTON AUTO MALL SOLAR PLUS BATTERY STORAGE 1 MUNICIPAL PL. CROTON ON HUDSON, NY 10520 ISSUED FOR PRICING & COORDINATION 04/04/2024 - CROTON ON HUDSON APPLICATION 04/25/2024 - SYSTEM INSTALLER: LIPPOLIS ELECTRIC CONTACT PERSON : PAUL LIPPOLIS EMAIL: PLIPPOLIS@LIPPOLISELECTRIC.COM TELEPHONE: 914-602-9663 SYSTEM OWNER: LOU GIORDANO LOUG@CROTONAUTOPARK.COM PHONE 914-548-1101 SYSTEM OPERATOR: SPROCKET OWNER EMAIL:DQUINN@SPROCKETPOWER.COM PHONE: 503-333-5475 CONTACT INFO THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. UTILITY ACCOUNT NO: 58890203710000 UTILITY METER NO: 009983133 ELECTRICAL DETAIL SHEET NTS PC WCP E-701