Agenda item: New Business — Cornell, Dennis, 19 Arrowcrest Drive (67.15-1-42) - Building Envelope Modification to Install an Inground Pool
Document, 7 pages. Attached to agenda item: “New Business — Cornell, Dennis, 19 Arrowcrest Drive (67.15-1-42) - Building Envelope Modification to Install an Inground Pool”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
19 Arrow Crest Drive Croton on Hudson 2024 10 23 Site...
19 Arrowcrest Planning Board Application Redacted
Aerial View 19 Arrowcrest
Arrowcrest Subdivision Map
Extracted text
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
SYMBOL
+252.
DRAIN PIPE
GRAVEL
TRENCH DRAIN
PATI
O
POOL WATER
COPING
ELEVATION MARKER
PROPERTY
BOUNDARY
SETBAC
K
FENCING
SILT FENCING
EXISTING GRADE
PROPOSED
GRADE
*As per New York State International Building Code Table 1806.2
4.
SAND, SILTY SAND,
CLAYEY SAND, SILTY
GRAVEL, & CLAYEY
GRAVEL (SW, SP, SM, SC,
GM, & GC)
LATERAL
PRESSURE
VERTICAL
PRESSURE
2,000 PSF
150 PSF/FT
BELOW GRADE
0.25
130 PSF
COHESIO
N
COEFFICIENT
OF FRICTION
CLASS OF MATERIALS
PRESUMPTIVE SOIL LOAD BEARING VALUES
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
S-101
SITE DEVELOPMENT POOL PLANS: 19 ARROWCREST DRIVE CROTON ON HUDSON, NY 10520
OVERVIEW OF WORK:
1.
NEW BELOW GROUND POOL AND SURROUNDING POOL
PATIO
BUILDING CODE AND REFERENCE STANDARDS:
THE 2020 RESIDENTIAL CODE OF NEW YORK STATE, AS ADOPTED
AND MODIFIED BY THE LOCAL JURISDICTION SHALL GOVERN
THE DESIGN AND CONSTRUCTION OF THIS PROJECT. REFERENCE
TO A SPECIFIC SECTION IN THE CODE DOES NOT RELIEVE THE
CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE MATERIALS
REFERENCE STANDARDS. THE LATEST EDITION OF THE
MATERIALS REFERENCE STANDARDS SHALL BE USED. EXISTING
BUILDING SHALL COMPLY WITH [NY] APPENDIX J FOR EXISTING
BUILDINGS AND STRUCTURES.
GENERAL NOTES:
1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE
BUILDING SITE BEFORE COMMENCEMENT OF WORK
2. ALL DIMENSIONS ARE TO ROUGH FRAMING
3. CONTRACTOR SHALL RECEIVE, STORE AND PROTECT ALL
MATERIALS DELIVERED TO THIS SITE FROM WEATHER AND
DAMAGE.
4. CONTRACTOR SHALL INSTALL ALL MATERIALS IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SITE CLEAN
UP ON A DAILY BASIS.
6. THE CONTRACTOR SHALL MAINTAIN A SET OF APPROVED
PLANS AT THE CONSTRUCTION SITE IN A SAFE PLACE FOR
REVIEW BY THE MUNICIPALITY BUILDING INSPECTOR
DURING CONSTRUCTION.
7. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE
PLANS AND SPECIFICATIONS.
8. CONTRACTOR SHALL NOT SCALE DRAWINGS.
9. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS. CHECK
DETAILS FOR APPROPRIATE LOCATION OF ALL ITEMS NOT
DIMENSIONED.
10. ALL CONSTRUCTIONS IS SUBJECT TO INSPECTION BY THE
BUILDING OFFICIAL. THE CONTRACTOR SHALL COORDINATE
ALL REQUIRED INSPECTION WITH BUILDING OFFICIAL AND
DOCUMENT FOR REVIEW AN INSPECTION REPORT.
11. DISCREPANCIES FOUND BY THE CONTRACTOR BETWEEN
FIELD CONDITIONS, NOTES, CONTRACT DRAWINGS,
SPECIFICATIONS, AND/OR REFERENCE STANDARDS, THE
ENGINEER SHALL DETERMINE WHICH SHALL GOVERN.
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF
THE ENGINEER BEFORE PROCEEDING WITH THE WORK.
1. ALL CONSTRUCTION SHALL COMPLY WITH LOCAL AND STATE
LAW AND ORDINANCES.
2. POOLS WITH DIVING BOARDS SHALL MEET DIVING BOARD
MANUFACTURER'S POOL GEOMETRIC STANDARDS AND/OR
LOCAL CODES.
3. SIGNS & SAFETY EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH LOCAL CODES.
4. CONTRACTOR OR OWNER SHALL VERIFY ALL FIELD CONDITIONS
& DIMENSIONS AT JOB SITE.
5. POOL LENGTH, GRADE BREAK LOCATIONS & DEPTH
DIMENSIONS AS NOTED ON THE PLOT PLAN SHALL COMPLY
WITH APSP SUGGESTED MINIMUM STANDARDS FOR RESIDENTIAL
POOLS OR APPLICABLE STATE AND LOCAL HEALTH
DEPARTMENTS REGULATIONS AND MANUFACTURERS
RECOMMENDATIONS.
6. A SITE SPECIFIC SOILS INVESTIGATION MAY BE REQUIRED BY
LOCAL AUTHORITIES HAVING JURISDICTION
7. WHERE FREEZING TEMPERATURES OCCUR, THE POOL SHALL BE
WINTERIZED TO PREVENT DAMAGE TO THE POOL STRUCTURE,
PLUMBING, AND POOL EQUIPMENT, CONTACT LOCAL
PROFESSIONAL FOR PROPER WINTERIZATION PROCEDURES.
8. NO GROUND WATER SHALL BE ABOVE ANY PORTION OF THE
POOL CONSTRUCTION.
9. ALL SURFACE WATER SHALL DRAIN AWAY FROM THE POOL.
10. ELECTRICAL INSPECTION SHALL APPROVE GROUNDING OF
REINFORCING, PLUMBING AND CONDUIT PRIOR TO THE
APPROVAL OF REINFORCING STEEL FOR POURING OF CONCRETE
OR GUNITE..
11. THE NOISE LEVEL FROM THE POOL EQUIPMENT LOCATED LESS
THAN 10 FEET FROM A PROPERTY LINE OF AN ADJOINING
PROPERTY, SHALL NOT EXCEED AMBIENT NOISE LEVEL BY MORE
THAN FIVE DECIBELS.
CONTINUOUS INSPECTION IS REQUIRED FOR SHOTCRETE/GUNITE
POOLS
POOL FOUNDATION NOTES:
1. ALL FOUNDATIONS, FOOTINGS AND SLABS SHALL BEAR ON
UNDISTURBED, NON-ORGANIC MATERIALS, COMPACTED STRUCTURAL
FILL OR CRUSHED STONE.
2. THE GENERAL CONTRACTOR SHALL CONFORM TO THE
REQUIREMENTS OF OSHAA REGARDING OPEN HOLES, SLOPE
STABILITY AND EXCAVATION PROCEDURES.
3. BACKFILLING OF FOUNDATIONS SHALL NOT EXCEED MORE THAN
2'-0" UNBALANCED BACK FILL CONDITIONS WITHOUT TEMPORARY
SHORING OF FOUNDATIONS WALLS, UNLESS FLOOR SYSTEM HAS BEEN
FRAMED OR DECKED.
4. WHEREVER BEDROCK IS ENCOUNTERED THE ROCK SHALL BE
REMOVED TO 2'-0" BELOW BOTTOM OF FOOTINGS OR 1;-0" BELOW
BOTTOM OF SLAB AND RESTORED IN 8" LIFTS OF COMPACTED
CRUSHED STONE.
5. A GEOTECHNICAL EXPLORATION AND TESTING HAS NOT BEEN
UNDERTAKEN. IT IS RESPONSIBILITY OF OWNER OR CONTRACTOR TO
UNDERTAKE ANY ADDITIONAL TEST PITS, BORINGS OR
INVESTIGATION AS NECESSARY TO ASSURE MINIMUM BEARING
CAPACITY.
STRUCTURAL NOTES
1.
SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 2000 PSF, CONCRETE
SHALL BE PLACED AGAINST UNDISTURBED SOIL OR BUILDING DEPARTMENT
APPROVED 90% COMPACT FILL. THIS PLAN IS NOT SUITABLE WHERE
POTENTIAL EXISTS FOR DIFFERENTIAL MOVEMENT FROM DISSIMILAR SOIL
CONDITIONS UNDER POOL. SUCH AS CUT-FILL TRANSITIONS.
2.
ALL REINFORCING STEEL SHALL BE DEFORMED BARS & CONFORM TO
ASTM A615 GRADE 40 #4 BARS, SPLICES TO BE LAPPED A MINIMUM OF 24".
MINIMUM CLEARANCE BETWEEN PARALLEL BARS IS 2-1/2".
3.
#4 BARS SHALL BE USED FOR THE BASIC GRID. THE MAXIMUM SPACING IS
#4 BARS AT 18" O.C..
4.
THE PLAN TABLES SPECIFY THE MINIMUM REQUIRED REINFORCEMENT.
FOR CONVENIENCE OF THE INSTALLER, THERE MAY BE MORE
REINFORCEMENT THAN SPECIFIED AT ANY GIVEN POINT IN THE POOL
STRUCTURE.
5.
GROUNDING/BONDING (PER THE LATEST ADOPTED EDITION OF THE
NATIONAL ELECTRICAL CODE) OF THE STRUCTURAL REINFORCING MUST BE
INSTALLED PRIOR TO PLACEMENT OF CONCRETE.
6.
SHOTCRETE (GUNITE) or CONCRETE SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. WHERE APPLICABLE,
SHOTCRETE (GUNITE) TO BE IN CONFORMANCE WITH IBC SECTION 1904
DURABILITY REQUIREMENTS. CONCRETE THAT WILL BE EXPOSED TO
FREEZING AND THAWING, DEICING CHEMICALS OR OTHER CONCRETE THAT
WILL BE SUBJECT TO THE FOLLOWING EXPOSURES SHALL CONFORM TO THE
CORRESPONDING MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIOS AND
MINIMUM SPECIFIED CONCRETE COMPRESSIVE STRENGTH REQUIREMENTS
OF ACI 318; CONCRETE INTENDED TO HAVE LOW PERMEABILITY WHERE
EXPOSED TO WATER, CONCRETE EXPOSED TO FREEZING AND THAWING IN A
MOIST CONDITION OR DEICER CHEMICALS, OR CONCRETE WITH
REINFORCEMENT WHERE THE CONCRETE IS EXPOSED TO CHLORIDES FROM
DEICING CHEMICALS, SALT, SALT WATER, BRACKISH WATER, SEAWATER OR
SPRAY FROM THESE SOURCES. CEMENT SHALL CONFORM TO ACI 318 SECTION
3.2, ASTM C 150.
7.
SHOTCRETE/GUNITE IN CONTACT WITH SOIL SHALL BE IN ACCORDANCE
WITH ACI 318 SECTION 4.3 FOR CONCRETE EXPOSURE TO SULFATE AND AS
DIRECTED BY LOCAL BUILDING OFFICIAL.
8.
KEEP CONCRETE DAMP CONTINUOUSLY FOR 14 DAYS.
9.
ALL INTERIOR SURFACES OF POOL/SPA SHALL BE COATED WITH A WATER-
RESISTANT SURFACE.
10. FLOOR TO WALL TRANSITION RADIUS MAY VARY DEPENDING ON
CONTRACTOR OR OWNER DESIGN INTENT. RADIUS SHALL NOT BE LESS THAN
1-FOOT AND SHALL NOT EXCEED 5-FEET.
11. IN AREAS WITH SOIL CONDITIONS SUBJECT TO FROST-HEAVE. THE
FOLLOWING REQUIREMENTS APPLY:
a.
IN ACCORDANCE WITH BUILDING CODE REQUIRMENT, THE ENTIRE
BOTTOM OF POOL STRUCTURE AND OR PLUMBING MUST EXTEND BELOW THE
FROST LINE OF THE LOCALITY.
b.
ALTERNATIVELY, WHERE DAMAGE TO THE POOL STRUCTURES, PLUMBING,
ADJACENT STRUCTURES AND SURFACE IMPROVEMENTS IS A CONCERN, SEF-
DRAINING GRANULAR BACKFILL MAY BE EXTENDED BELOW THE FROST-LINE
WITH A MEANS TO PRECLUDE BUILD-UP OF WATER.
ENTRAPMENT PROTECTION REQUIREMENTS
1. SUCTION OUTLETS MUST BE DESIGNED TO PRODUCE CIRCULATION
THROUGHOUT THE POOL OR SPA.
2. SINGLE OUTLET SYSTEMS, SUCH AS AUTOMATIC VACUUM CLEANER
SYSTEMS, OR OTHER SUCH MULTIPLE SUCTION OUTLETS WHETHER
ISOLATED BY VALVES OR OTHERWISE MUST BE PROTECTED AGAINST
USER ENTRAPMENT.
3. ALL POOL AND SPA SUCTION OUTLETS (EXCEPT SURFACE SKIMMERS)
MUST BE PROVIDED WITH:
O
A COVER THAT CONFORMS WITH REFERENCE STANDARD ASME/
ANSI A112.19.8M, ENTITLED SUCTION FITTINGS FOR THE USE IN
SWIMMING POOLS, WADING POOLS, SPAS, HOT TUBS, AND WHIRLPOOL
BATHTUB APPLIANCES, OR
O
A DRAIN GATE THAT IS 12" x 12" OR LARGER, OR
O
A CHANNEL DRAIN SYSTEM APPROVED BY THE LOCAL CODE
ENFORCEMENT OFFICIAL.
4.
ALL POOL AND SPA SINGLE OR MULTIPLE OUTLET CIRCULATION
SYSTEMS MUST BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF
SHOULD GRATE COVERS LOCATED THEREIN BECOME MISSING OR
BROKEN. SUCH VACUUM RELIEF SYSTEMS SHALL INCLUDE AT LEAST
ONE OF THE FOLLOWING:
O
SAFETY VACUUM RELEASE SYSTEM CONFORMING TO REFERENCE
STANDARD ASME A112.19.17, ENTITLED MANUFACTURERS SAFETY
VACUUM RELEASE SYSTEMS (SVRS) FOR RESIDENTIAL AND COMMERCIAL
SWIMMING POOL, SPA, HOT TUB AND WADING POOL, OR
O
A GRAVITY DRAINAGE SYSTEM APPROVED BY THE LOCAL CODE
ENFORCEMENT OFFICIAL.
5.
SINGLE OR MULTIPLE PUMP CIRCULATION SYSTEMS MUST BE
PROVIDED WITH A MINIMUM OF TWO (2) SUCTION OUTLETS OF THE
APPROVED TYPE.
6.
THE SUCTION OUTLETS MUST BE SEPARATED BY A MINIMUM
HORIZONTAL OR VERTICAL DISTANCE OF THREE (3) FEET.
7.
THESE SUCTION OUTLETS MUST BE PIPED SO THAT WATER IS DRAWN
THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM
RELIEF-
PROTECTED LINE TO THE PUMP OR PUMPS.
8.
IF THE POOL OR SPA IS EQUIPPED WITH VACUUM OR PRESSURE
CLEANER FITTING(S), EACH FITTING MUST BE LOCATED:
O
IN AN ACCESSIBLE POSITION WHICH IS AT LEAST SIX (6) INCHES AND
NOT GREATER THAN TWELVE (12) INCHES BELOW THE MINIMUM
OPERATIONAL WATER LEVEL, OR
O
AS AN ATTACHMENT TO THE SKIMMER(S).
POOL ALARM REQUIREMENTS:
EVERY SWIMMING POOL THAT IS INSTALLED, CONSTRUCTED OR
SUBSTANTIALLY MODIFIED AFTER DECEMBER 14, 2006 MUST BE EQUIPPED
WITH AN APPROVED POOL ALARM WHICH:
·
IS CAPABLE OF DETECTING A CHILD ENTERING THE WATER AND GIVING
AN AUDIBLE ALARM WHEN IT DETECTS A CHILD ENTERING THE WATER;
·
IS AUDIBLE POOLSIDE AND AT ANOTHER LOCATION ON THE PREMISES
WHERE THE SWIMMING POOL IS LOCATED;
·
IS INSTALLED, USED AND MAINTAINED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS;
·
IS CLASSIFIED TO REFERENCE STANDARD ASTM F2208, ENTITLED
STANDARD SPECIFICATION FOR POOL ALARMS (EITHER THE VERSION
ADOPTED IN 2002 AND EDITORIALLY CORRECTED IN JUNE 2005, OR THE
VERSION ADOPTED IN 2007); AND
·
IS NOT AN ALARM DEVICE WHICH IS LOCATED ON PERSON(S) OR WHICH IS
DEPENDENT ON DEVICE(S) LOCATED ON PERSON(S) FOR ITS PROPER
OPERATION.
ELECTRICAL AND PLUMBING
ALL ELECTRICAL SHALL BE IN CONFORMANCE WITH NEC.
1. IN ACCORDANCE WITH NEC REQUIRMENTS ALL METAL WITHIN 5' HORIZ. OF
INSIDE WALL OF POOL AND 12' VERT. ABOVE WATER LINE MUST BE BONDED
VIA EQUIPOTENTIAL BONDING GRID. BONDING GRID SHALL EXTEND
UNDER PAVED WALKING SURFACES 3' HORIZ. BEYOND INSIDE WALL OF
POOL. CONCRETE REINFORCING TIE WIRES SHALL BE MADE TIGHT FOR
BONDING PURPOSES.
2. OBTAIN ELECTRICAL AND PLUMBING PERMITS ALONG WITH POOL
BUILDING PERMIT.
3. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS.
4. POOLS SHALL BE EQUIPPED WITH A FILTERING SYSTEM & A DRAIN.
5. BACKWASH SHALL BE DISPOSED OF IN AN APPROVED MANNER.
6. POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN
CONFORMANCE WITH ALL LOCAL CODE REQUIRMENTS.
7. WHERE REINFORCING STEEL IS ENCAPSULATED WITH A NONCONDUCTIVE
COMPOUND, PROVISIONS SHALL BE MADE FOR AN ALTERNATIVE MEANS TO
ELIMINATE VOLTAGE GRADIENTS THAT WOULD OTHERWISE BE PROVIDED
BY BONDED REINFORCING STEEL.
ENERGY STATEMENT:
I, JOHN M. SCAVELLI, CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THIS
DRAWING PACKAGE IS PREPARED IN CONFORMANCE WITH THE 2020 ENERGY
CONSERVATION CODE OF NEW YORK STATE CODE REQUIREMENTS FOR THE
CLIMATE ZONE AND BUILDING TYPE LISTED BELOW.
CLIMATE ZONE: ZONE (4) WESTCHESTER
BUILDING TYPE: 1- FAMILY RESIDENTIAL
TEMPORARY POOL ENCLOSURES:
1. DURING THE INSTALLATION OR CONSTRUCTION OF A SWIMMING POOL, THE SWIMMING POOL
MUST BE ENCLOSED BY A TEMPORARY ENCLOSURE. THE TEMPORARY MAY CONSIST OF A
TEMPORARY FENCE, A PERMANENT FENCE. THE WALL OF A PERMANENT STRUCTURE, ANY
OTHER STRUCTURE, OR ANY COMBINATION OF THE FOREGOING, HOWEVER:
2. ALL PORTIONS OF THE TEMPORARY ENCLOSURE MUST BE AT LEAST FOUR(4) FEET HIGH, AND
3. ALL COMPONENTS OF THE TEMPORARY ENCLOSURE MUST BE SUFFICIENT TO PREVENT ACCESS
TO THE SWIMMING POOL BY ANY PERSON NOT ENGAGED IN THE INSTALLATION OR
CONSTRUCTION PROCESS AND TO PROVIDE FOR THE SAFETY OF ALL SUCH PERSONS.
4. THE TEMPORARY ENCLOSURE MUST REMAIN IN PLACE THROUGHOUT THE PERIOD OF
INSTALLATION OR CONSTRUCTION OF THE SWIMMING POOL, AND THEREAFTER UNTIL THE
INSTALLATION OR CONSTRUCTION OF A PERMANENT ENCLOSURE HAS BEEN COMPLETED. THE
TEMPORARY ENCLOSURE MUST BE REPLACED BY A PERMANENT ENCLOSURE. THE PERMANENT
ENCLOSURE MUST COMPLY WITH ALL APPLICABLE NEW YORK STATE CODES OR REGULATIONS
APPLICABLE TO SWIMMING POOL ENCLOSURES OR BY ANY LOCAL LAW APPLICABLE TO
SWIMMING POOL ENCLOSURES AND IN EFFECT IN THE LOCATION WHERE THE SWIMMING
POOL HAS BEEN INSTALLED OR CONSTRUCTED.
5. THE PERMANENT ENCLOSURE MUST BE COMPLETE WITHIN NINETY DAYS AFTER THE DATE OF
ISSUANCE OF THE BUILDING PERMIT FOR THE INSTALLATION OR CONSTRUCTION OF THE
SWIMMING POOL, OR THE DATE OF COMMENCEMENT OF THE INSTALLATION OR
CONSTRUCTION OF THE SWIMMING POOL, WHICHEVER IS LATER.
ENCLOSURES AND SAFETY DEVICES
1.
PRIOR TO FILLING, THE POOL AND OR SPA SHALL BE COMPLETELY ENCLOSED BY 4' MIN. HIGH
FENCING & GATES WITH NO OPENINGS GREATER THAN 4". GATES TO BE SELF- CLOSING & SELF-
LATCHING WITH LATCH A MIN. OF 4' HIGH. WHERE THIS VARIES FROM LOCAL CODES, THE LOCAL
CODES SHALL PREVAIL.
SUCTION OUTLETS SHALL BE DESIGNED TO PRODUCE CIRCULATION THROUGHOUT THE POOL OR
SPA. SINGLE-OUTLET SYSTEMS. SUCH AS AUTOMATIC VACUUM CLEANER SYSTEMS, OR OTHER SUCH
MULTIPLE SUCTION OUTLETS WHETHER ISOLATED BY VALVES OR OTHERWISE SHALL BE
PROTECTED AGAINST USER ENTRAPMENT. ALL POOL AND SPA SUCTION OUTLETS SHALL BE
PROVIDED WITH A COVER THAT CONFORMS TO ASME A112.19.8M, A 12-INCH BY 12-INCH DRAIN
GRATE OR LARGER, OR AN APPROVED CHANNEL DRAIN SYSTEM WITH THE EXCEPTION OF SURFACE
SKIMMERS.
IN ADDITION, WHEN REQUIRED BY CODE, ALL POOL AND SPA SINGLE- OR MULTIPLE-OUTLET
CIRCULATION SYSTEMS SHALL BE EQUIPPED WITH AN ATMOSPHERIC VACUUM RELIEF SHOULD
GRATE COVERS LOCATED THEREIN BECOME MISSING OR BROKEN. SUCH VACUUM RELIEF SYSTEMS
SHALL INCLUDE AT LEAST ONE APPROVED OR ENGINEERED METHOD OF THE TYPE SPECIFIED
HEREIN, AS FOLLOWS: 1. SAFETY VACUUM RELEASE SYSTEMS CONFORMING TO ASME A112.19.17S; OR
2. APPROVED GRAVITY DRAINAGE SYSTEM.
IN ADDITION, WHEN REQUIRED BY CODE, SINGLE- OR MULTIPLE-PUMP CIRCULATION SYSTEMS
SHALL BE PROVIDED WITH A MINIMUM OF TWO SUCTION OUTLETS OF THE APPROVED TYPE. A
MINIMUM HORIZONTAL OR VERTICAL DISTANCE OF 3 FEET SHALL SEPARATE SUCH OUTLETS. THESE
SUCTION OUTLETS SHALL BE PIPED SO THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY
THROUGH A VACUUM-RELIEF-PROTECTED LINE TO THE PUMP OR PUMPS.
IN ADDITION, WHERE PROVIDED, VACUUM OR PRESSURE CLEANER FITTINGS(S) SHALL BE LOCATED
IN AN ACCESSIBLE POSITION(S) AT LEAST 6 INCHES AND NOT GREATER THAN 12 INCHES BELOW THE
MINIMUM OPERATIONAL WATER LEVEL OR AS AN ATTACHMENT TO THE SKIMMER(S).
BARRIER REQUIREMENTS: OUTDOOR RESIDENTIAL SWIMMING POOLS
AN OUTDOOR RESIDENTIAL SWIMMING POOL MUST BE PROVIDED WITH A BARRIER WHICH
COMPLETELY SURROUNDS THE SWIMMING POOL AND OBSTRUCTS ACCESS TO THE SWIMMING POOL.
PROPOSED BARRIER FOR THIS POOL INSTALLATION SHALL BE BY MEANS OF FENCING
BARRIERS PROVIDED FOR OUTDOOR RESIDENTIAL SWIMMING POOLS MUST SATISFY THE
FOLLOWING REQUIREMENTS:
·
THE BARRIER MUST COMPLETELY SURROUND THE SWIMMING POOL AND MUST OBSTRUCT
ACCESS TO THE SWIMMING POOL.
·
THE BARRIER MUST BE AR LEAST 4 FEET (48 INCHES) HIGH.
·
THE SPACE BETWEEN THE BOTTOM OF THE BARRIER AND THE GROUND CANNOT EXCEED 2
INCHES.
DWELLING WALL AS BARRIER
1. WALLS OF DWELLING THAT SERVE AS PART OF BARRIER SHALL COMPLY WITH RCNYS R326.4.2.8
REQUIREMENTS.
2. ANY DOOR & WINDOW WITH DIRECT ACCESS TO POOL SHALL BE EQUIPED WITH AUDIBLE ALARM
IN ACCORDANCE WITH UL 2017
3. ACTIVATION TIMING SHALL BE IN COMPLIANCE WITH R326.4.2.6 A
4. ANY OPERABLE WINDOWS IN THE WALL SHALL HAVE LATCHING DEVICE LOCATED NO LESS THAN
48 INCHES ABOVE FLOOR.
5. OPENINGS IN OPERABLE WINDOWS SHALL NOT ALLOW A 4 INCH DIA. SPHERE TO PASS THROUGH\
6. WHERE AN ALARM IS PROVIDE THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR
MORE ABOVE THE THRESHOLD OF THE DOOR.
POOL HEATER NOTES:
1. A READILY ACCESSIBLE ON-OFF SWITCH THAT IS AN INTEGRAL PART OF THE HEATER SHALL BE
PROVIDED IN COMPLIANCE WITH 2020 RCNYS N1103.10.1
2. A TIME SWITCH WITH PRE-SET SCHEDULE CONTROL SHALL BE INSTALLED FOR HEATER AND
PUMP MOTORS.
3. POOL COVER SHALL BE PROVIDED FOR HEATED POOL WITH MINIMUM R-VALUE OF R-12.
4. ENERGY CONSUMPTION OF POOLS SHALL BE IN ACCORDANCE WITH RCNYS SECTION N1103.10.1-3
SITE IMPROVEMENTS
SHEET 1
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 2
S-102
EROSION CONTROL MEASURE NOTES:
1. ALL CLEARING & GRADING CONSTRUCTION MUST BE IN ACCORDANCE WITH THE NEW
YORK STATE STANDARDS AND SPECIFICATIONS FOR EROSION CONTROL AND ALL
OTHER APPLICABLE CODES, ORDINANCES, AND STANDARDS. THE DESIGN ELEMENTS
WITHIN THESE PLANS HAVE BEEN REVIEWED ACCORDING TO THESE REQUIREMENTS.
ANY VARIANCE FROM ADOPTED EROSION CONTROL STANDARDS IS NOT ALLOWED
UNLESS SPECIFICALLY APPROVED BY THE LOCAL AUTHORITY HAVING JURSIDICTION..
2. APPROVAL OF THIS EROSION CONTROL MEASURES DOES NOT CONSTITUTE AN
APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN.
3. A COPY OF THE APPROVED PLANS AND DRAWINGS MUST BE ON-SITE DURING
CONSTRUCTION. THE APPLICANT IS RESPONSIBLE FOR OBTAINING ANY OTHER
REQUIRED OR RELATED PERMITS PRIOR TO BEGINNING CONSTRUCTION.
4. THE IMPLEMENTATION OF THESE PLANS AND THE CONSTRUCTION, MAINTENANCE,
REPLACEMENT, AND UPGRADING OF THESE FACILITIES IS THE RESPONSIBILITY OF
THE CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED AND
VEGETATION/LANDSCAPING IS ESTABLISHED.
5. THE EROSION CONTROL MEASURES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN
CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH A
MANNER AS TO INSURE THAT SEDIMENT AND SEDIMENT LADEN WATER DO NOT
ENTER THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER
STANDARDS.
6. THE EROSION CONTROL MEASURES SHOWN ON THIS PLAN ARE THE MINIMUM
REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION
PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED
STORM EVENTS AND TO ENSURE THAT SEDIMENT AND SEDIMENT-LADEN WATER DO
NOT LEAVE THE SITE.
7. ALL LOCATIONS OF EXISTING UTILITIES SHALL BE ESTABLISHED BY FIELD SURVEY OR
OBTAINED FROM AVAILABLE RECORDS AND SHOULD, THEREFORE, BE CONSIDERED
ONLY APPROXIMATE AND NOT NECESSARILY COMPLETE. IT IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY
OF ALL UTILITY LOCATIONS AND TO DISCOVER AND AVOID ANY OTHER UTILITIES
NOT SHOWN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN.
8. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY
FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION
PERIOD, NO DISTURBANCE BEYOND THE FLAGGED CLEARING LIMITS SHALL BE
PERMITTED. THE FLAGGING SHALL BE MAINTAINED BY THE CONTRACTOR FOR THE
DURATION OF CONSTRUCTION.
9. CLEARING SHALL BE LIMITED TO THE AREAS WITHIN THE APPROVED DISTURBANCE
LIMITS. EXPOSED SOILS MUST BE COVERED AT THE END OF EACH WORKING DAY
WHEN WORKING .
10. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING
OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT.
11. THE CONTRACTOR MUST MAINTAIN A SWEEPER ON SITE DURING EARTHWORK AND
IMMEDIATELY REMOVE SOIL THAT HAS BEEN TRACKED ONTO PAVED AREAS AS
RESULT OF CONSTRUCTION.
12. THE EROSION CONTROL FACILITIES SHALL BE INSPECTED DAILY BY THE CONTRACTOR
AND MAINTAINED AS NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING.
13. FINAL SITE GRADING MUST DIRECT DRAINAGE AWAY FROM ALL BUILDING
STRUCTURES AT A MINIMUM OF 6" WITHIN THE FIRST 10 FEET, PER THE
INTERNATIONAL RESIDENTIAL CODE R401.3.
ADDITIONAL NOTES:
1. THE APPLICANT SHALL PROVIDE AN AS-BUILT PLAN OF THE STORM WATER
MANAGEMENT SYSTEM (FOR ALL STORM WATER FEATURES INCLUDING,
BUT NOT LIMITED TO, LOCATIONS OF STORM WATER INFRASTRUCTURE,
INVERT/RIM ELEVATIONS, PIPE LOCATIONS AND SIZES, FINAL GRADING,
ETC.) CERTIFIED BY THE ENGINEER OF RECORD, PRIOR TO THE ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY. THE AS-BUILT PLAN SHALL ALSO
INCLUDE THE FINAL MAINTENANCE SCHEDULE FOR THE STORM WATER
MANAGEMENT FEATURES.
2. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL CONFORM TO
THE THE NEW YORK STATE STANDARDS AND SPECIFICATIONS FOR
EROSION AND SEDIMENT CONTROL, DATED NOVEMBER 2016.
3. SOIL RESTORATION AT THE COMPLETION OF CONSTRUCTION SHALL BE
IMPLEMENTED IN ACCORDANCE WITH THE SOIL RESTORATION
STANDARDS SPECIFIED IN CHAPTER 5 OF THE NEW YORK STATE
DEPARTMENT OF CONSERVATION'S STORM WATER MANAGEMENT DESIGN
MANUAL FOR THE RESTORATION OF SURFACES.
4. TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES CANNOT BE
REMOVED UNTIL SITE STABILIZATION (80% UNIFORM DENSITY OF
PERMANENT VEGETATION OR PERMANENT MULCH/STONE) HAS BEEN
ACHIEVED.
5. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL LOCATED ALL BURIED
UTILITIES TO ENSURE THERE ARE NO INTERFERENCE EXISTING DURING
CONSTRUCTION ACTIVITIES.
6. ANY IMPORTED SOIL SHALL COMPLY WITH ALL FEDERAL, STATE AND
LOCAL REQUIREMENTS FOR QUALITY AND USE.
7. OFF SITE DISPOSAL OF EXCESS CUT SHALL BE IN ACCORDANCE WITH ALL
FEDERAL, STATE AND LOCAL REQUIREMENTS.
MATERIAL REMOVAL NOTES:
1. NO MATERIALS SHALL BE EXCAVATED OR REMOVED EXCEPT FROM THOSE AREAS AND
PORTIONS OF EXCAVATED PREMISES AS ARE INDICATED FOR EXCAVATION OR
REMOVAL ON SITE PLAN.
2. NO MATERIALS SHALL BE EXCAVATED OR REMOVED FROM ANY AREA OR PORTION OF
THE EXCAVATED PREMISES AT ANY DEPTH BELOW THE PROPOSED GRADE SHOWN FOR
SUCH AREA OR PORTION OF AREA.
3. THE GRADES AND SLOPES OF THE EXCAVATED PREMISES SHALL BE FINISHED IN
ACCORDANCE WITH ALL DETAILS SHOWN ON TOPOGRAPHICAL MAP.
CONSTRUCTION SEQUENCING NOTES:
1. APPROVAL OF PERMIT BY LOCAL JURISDICTION
2. ESTABLISH CONSTRUCTION ENTRANCE AND STAGING AREAS
3. INSTALL SILT FENCE AROUND PERIMETER OF CONSTRUCTION AS SHOWN ON
PLAN
4. REMOVE ANY SHRUBS OR VEGETATION WHERE NECESSARY
5. REMOVE TOPSOIL AND STOCKPILE AT LOCATIONS SPECIFIED ON THE PLANS.
6. DEMOLISH AND DISPOSE OF EXISTING POOL STRUCTURE AND SURROUNDING
DECKING
7. EXCAVATE AND CONSTRUCT FORMWORK FOR NEW POOL STRUCTURE
8. INSTALL UNDERGROUND UTILITIES TO POOL STRUCTURE.
9. SET GUNITE POOL STRUCTURE IN PLACE
10. SET SURROUNDING PATIO BASE LAYERS
11. CONSTRUCTION AND INSTALLATION OF SUBSURFACE STORWATER
MANAGEMENT CHAMBERS
12. INTALL ALL TRENCH DRAINS AND PIPING FOR STORMWATER DRAINAGE
SYSTEM.
13. INSTALL FINAL PATIO FINISH LAYERS
14. CLEAN ALL STORMWATER SYSTEM LINES, BASINS, TRENCH DRAINS AND
COMPONENTS.
15. REMOVE ALL TEMPORARY SOIL EROSION AND SEDIMENT CONTROL
MEASURES AFTER SITE HAS ACHIEVED FINAL STABILZATION. (80% OF
UNIFORM DENSITY OF PERMANENT VEGETATION OR PERMANENT MULCH
STONE)
16. EROSION AND SEDIMENT CONTROL MAINTENANCE MUST OCCUR ON
REGULAR WEEKLY BASIS AND AFTER ANY RAINFALL EVENTS.
LANDSCAPING NOTES:
1. FURNISH ALL MATERIALS, LABOR AND RELATED ITEMS AS REQUIRED FOR
LANDSCAPING FINISHES AROUND PREMISES.
2. ALL DISTURBED GRASS AREAS SHALL BE REPLANTED WITH NEW GRASS SEED AND
SHALL BE APPROPRIATELY COVERED TO FACILITATE NEW SEASONAL GRASS GROWTH.
3. ALL DEBRIS, ROCKS, FOREIGN OBJECTS OVER 2" DIAMETER SHALL BE REMOVED FROM
TOP SURFACE OF ALL PREPARED LANDSCAPE AREAS PRIOR TO ANY NEW LANDSCAPING
WORK.
4. SEED MIXTURE CONTAINING 40% PERENNIAL RYE GRASS, 25% CHEWING FESCUE AND
10% OF MIXED CLOVER OR SIMILAR COVERAGE SHALL BE SPREAD OVER EXCAVATED
PREMISES AT THE RATE OF 100 POUNDS PER ACRES. SEED SHALL BE BRUSHED IN
LIGHTLY AND ROLLED FIRM.
5. EXISTING TREES AND SHRUBS ON SITE SHALL BE PROTECTED DURING CONSTRUCTION.
6. EXISTING SHRUBS AND TREES SHALL BE GROOMED AND TRIMMED AND ALL
ADDITIONAL DEBRIS TO BE REMOVED FROM SITE.
CONCRETE WASHOUT SPECIFICATIONS:
1. A CONCRETE WASHOUT STATION SHALL BE PROVIDED IN COMPLIANCE WITH
NEW YORK STATE STANDARDS AND SPECIFICATIONS FOR EROSION AND
SEDIMENT CONTROL 2016.
2. A TEMPORARY EXCAVATED OR ABOVE GROUND LINED PUT WHERE
CONCRETE TRUCK MIXERS AND EQUIPMENT CAN BE WASHED SHALL BE
PROVIDED ON SITE.
3. WATER FROM CONCRETE WASH OUT ACTIVITIES SHALL NOT BE ALLOWED TO
INFILTRATED INTO SOIL OR NEARBY SURFACE WATERS.
4. MINIMUM SIZE FOR WASHOUT HSLAL BE 8 FEET BY 8 FEET AND 2 FEET DEEP.
5. ALL WASHOUT FACILITIES SHALL BE LINED WITH MINIMUM 10 MIL THICKNESS
PLASTIC LINER TO PREVENT LEACHING OF LIQUID INTO GROUND. THERE
SHALL BE NO HOLES OR TEARS WITHIN LINER.
6. IF PRE FABRICATED WASHOUTS ARE USED THEY MUST ENSURE CAPTURE AND
CONTAINMENT OF CONCRETE WASH AND BE SIZED BASED ON EXPECTED
FREQUENCY OF USED.
7. ALL CONCRETE WASHOUT FACILITIES SHALL BE INSPECTED DAILY.
8. DAMAGED FACILITIES SHALL B E REPAIRED OR REPLACED IMMEDIATELY.
9. ACCUMULATED HARDENED MATERIAL SHALL BE REMOVED WHEN 75% OF
THE STORAGE CAPACITY OF THE STRUCTURE IS FILLED.
10. ANY EXCESS WASH WATER SHALL BE PUMPED INTO A CONTAINMENT VESSEL
AND PROPERLY DISPOSED OF OFF SITE.
11. DISPOSAL WASHOUT WATER SHALL BE PROHIBITED TO DRAIN TO ANY ONSITE
STORM WATER FACILITIES.
CONSTRUCTION SEQUENCING NOTES:
1. APPROVAL OF PERMIT BY LOCAL JURISDICTION
2. ESTABLISH CONSTRUCTION ENTRANCE AND STAGING AREAS
3. INSTALL SILT FENCE AROUND PERIMETER OF CONSTRUCTION AS SHOWN
ON PLAN
4. REMOVE ANY SHRUBS OR VEGETATION WHERE NECESSARY
5. REMOVE TOPSOIL AND STOCKPILE AT LOCATIONS SPECIFIED ON THE
PLANS.
6. DEMOLISH AND DISPOSE OF EXISTING POOL STRUCTURE AND
SURROUNDING DECKING
7. EXCAVATE AND CONSTRUCT FORMWORK FOR NEW POOL STRUCTURE
8. INSTALL UNDERGROUND UTILITIES TO POOL STRUCTURE.
9. SET GUNITE POOL STRUCTURE IN PLACE
10. SET SURROUNDING PATIO BASE LAYERS
11. CONSTRUCTION AND INSTALLATION OF SUBSURFACE STORWATER
MANAGEMENT CHAMBERS
12. INTALL ALL TRENCH DRAINS AND PIPING FOR STORMWATER DRAINAGE
SYSTEM.
13. INSTALL FINAL PATIO FINISH LAYERS
14. CLEAN ALL STORMWATER SYSTEM LINES, BASINS, TRENCH DRAINS AND
COMPONENTS.
15. REMOVE ALL TEMPORARY SOIL EROSION AND SEDIMENT CONTROL
MEASURES AFTER SITE HAS ACHIEVED FINAL STABILZATION. (80% OF
UNIFORM DENSITY OF PERMANENT VEGETATION OR PERMANENT MULCH
STONE)
16. EROSION AND SEDIMENT CONTROL MAINTENANCE MUST OCCUR ON
REGULAR WEEKLY BASIS AND AFTER ANY RAINFALL EVENTS.
EROSION AND SEDIMENT CONTROL PLAN
1. APPROVAL OF PERMIT
2. SCHEDULE A PRE-CONSTRUCTION MEETING WITH APPROPRIATE
PERMITTING AUTHORITY IF REQUIRED.
3. DELINEATE ANY ON SITE RESOURCES THAT WILL BE PROTECTED
4. ESTABLISH STAGING AREA, CONSTRUCTION ENTRANCE, TOP SOIL
STOCKPILE, AND CONCRETE TRUCH WASHOUT ARES
5. PROTECT POST CONSTRUCTION PRACTICE AREAS DURING CONSTRUCTION
TO PRESERVE NATIVE SOIL PERMEABILITY, INSTALL SILT FENCE ONLY
AFTER SITE IS STABILIZED
6. CLEARING AND GRUBBING AS NECESSARY FOR THE INSTALLATION OF
PERIMETER CONTROLS.
7. ESTABLISH METHOD OF SPOILS (ON-SITE OR OFF)
8. CONSTRUCTION AND STABILIZATION OF PERIMETER CONTROLS
9. INSTALL INITIAL RUNOFF CONTROLS AND STABILIZATION
10. REMAINING CLEARING AND GRUBBING WITHIN PERIMETER
11. SITE GRADING
12. UTILITY INSTALLATION AND CONNECTIONS
13. INSTALLATION OF PERMANENT STORM WATER MANAGEMENT MEASURES
14. CONDUCT SOIL RESTORATION
15. FINAL GRADING, LANDSCAPING AND STABILIZATION
16. REMOVAL OF TEMPORARY EROSION AND SEDIMENT CONTROLS
17. RESTORE AND STABILIZE ANY DISTURBED AREAS REMAINING UPON
REMOVAL OF TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES.
ADDITIONAL POOL CODE REQUIREMENTS:
1. INGROUND POOL DESIGNED IN CONFORMANCE WITH ANSI/APSP/ICC PER SECTION 326.3.2 OF
THE 2020 NEW YORK STATE RESIDENTIAL CODE.
2. POOL ENCLOSURE SHALL COMPLY WITH CODE SECTION R326.4.2 - PERMANENT BARRIERS.
3. POTABLE WATER PROTECTION FOR SWIMMING POOLS SHALL COMPLY WITH CODE SECTION
P2902 OF THE 2020 NYS RESIDENTIAL CODE.
4. ENTRAPMENT PROTECTION SHALL MEET CODE SECTION R326.5 OF THE 2020 NYS RESIDENTIAL
CODE.
5. ALL SUCTION FITTINGS SHALL COMPLY WITH "ANSI/APSP/ICC 7 PER CODE SECTION R326.5.1.
6. ELECTRICAL SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF
2020 RESIDENTIAL CODE OF NEW YORK STATE CHAPTER 42 SWIMMING POOLS.
ADDITIONAL REQUIREMENTS:
1. CONTRACTOR SHALL SCHEDULE ALL REQUIRED EROSION AND SEDIMENT CONTROL
INSPECTIONS WITH THE TOWN ENGINEER WHICH WILL INCLUDE FINAL SIGN OFF APPROVAL
FROM THE TOWN ENGINEER.
2. THE PROPOSED IN-GROUND POOL IS DESIGNED AND WILL BE CONSTRUCTED IN CONFORMANCE
WITH ANSI/APSP/ICC 5 & THAT THE PROPOSED SPA WILL BE CONSTRUCTED IN CONFORMANCE
WITH ANSI/APSP/ICC 3.
3. THE SUCTION GRATE COVERS SHALL CONFORM TO ANSI/ASME A112.19.18.
4. ALL GATES SHALL BE SELF LATCHING, WITH THE LATCH HANDLE LOCATED WITHIN THE
ENCLOSURE (POOL SIDE OF ENCLOSURE) AND AT LEAST 40'' ABOVE GRADE. IN ADDITION, IF THE
LATCH HANDLE IS LOCATED LESS THAN 54'' FROM GRADE THEN THE LATCH HANDLE SHALL BE
LOCATED WITHIN AT LEAST 3'' BELOW THE TOP OF THE GATE, AND NEITHER THE GATE NOR THE
BARRIER SHALL HAVE ANY OPENING GREATER THAN 0.5 INCH WITHIN 18'' OF LATCH HANDLE
A
AERIAL VIEW
SCALE: NTS
G
GIS VIEW
SCALE: NTS
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
ALIGN POOL EDGE
PARALLEL TO PRINCIPAL
BUILDING
A STORM WATER ENGINEERING
AND EROSION CONTROL
PERMIT SHALL BE OBTAINED
AS REQUIRED BY LOCAL
JURISDICTION
AREA OF DISTURBANCE:
DISTURBANCE SHALL BE
STAKED IN FIELD SILT FENCE TO
SURROUND CONSTRUCTION
SITE
ALL SUCTION FITTING SHALL
COMPLY WITH ANSI/SPSP/ICC
PER CODE SECTION R326.5.1
ENTRAPMENT PROTECTION
SHALL COMPLY WITH R326.5
POOL BARRIER MUST BE AT
LEAST 48" ABOVE GRADE AND
MUST COMPLETELY
SURROUND SWIMMING POOL
AREA POOL ENCLOSURE TO
COMPLY WITH R326.4.2
PERMANENT BARRIERS
FOR PROPOSED REGRADING
REFER TO SITE PLAN
ELECTRICAL INSTALLATION
SHALL BE INSTALLED BY
LICENSED ELECTRICAL
CONTRACTOR IN ACCORDANCE
WITH NYSRC CHAPTER 42-
SWIMMING POOLS
POTABLE WATER PROTECTION
FOR POOL TO COMPLY WITH
P2902 OF NYSRC
NO TREES TO BE REMOVED AS
PART OF PROJECT
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 3
S-103
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
Pool Slide
12'
1'-2"
20'
1'-2"
6'
1'-2"
40'
1'-2"
6'
48'-4"
40'-4"
800 sq ft
POOL
ELEVATION
+424.5
ELEVATION
+419.0
ELEVATION
+428.0
ELEVATION
+428.0
ELEVATION
+428.0
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
2% SLOPE
YARD DRAIN ELEVATION
+427.0
YARD DRAIN ELEVATION
+426.5
YARD DRAIN OUTLET
+426.0
TRENCH DRAIN ELEVATION
+427.0
TRENCH DRAIN ELEVATION
+426.5
DRYWELL INLET
+423.0
PRE-TREATMENT GRATE
+428.0
PRE-TREATMENT OUTLET
+425.0
POOL PATIO
1,004 SF
BOTTOM OF DRYWELL
+421.0
TOP OF DRYWELL
+423.5
PRE-TREATMENT BASIN
+424.0
NEW PATIO
ASSEMBLY SEE
DETAILS
NEW POOL PATIO
TO SURROUND
POOL
NEW 14"
COPING
NEW POOL
ASSEMBLY SEE
DETAILS
NEW TRENCH
DRAIN REFER
TO DETAILS
NEW YARD
DRAIN REFER
TO DETAILS
12" GRAVEL
SURROUND
REFER TO DETAILS
PRE-TREATMENT BASIN
REFER TO DETAILS
NEW DRYWELL
REFER TO DETAILS
6" DIA. SDR-35 PIPING SHALL
BE CONNECTED FROM DRAIN
TO INFILTRATION SYSTEM
MIN. 2% DRAINAGE SLOPE
PROVIDE
INSPECTION PORT
NEW 14"
COPING
BOULDER
STEPS
POOL SLIDE
INSTALL IN
COMPLIANCE WITH
MANUFACTURER
REQUIREMENTS
GROTTO
AREA
DRYWELL DRAIN PIPING - 6"PVC DRAINAGE PIPING
EMERGENCY OUTLET PIPING - 3"PVC DRAINAGE PIPING
FORCE MAIN FROM POOL EQUIPMENT PIPING - 2" PVC DRAINAGE
PIPING
ALL PROPOSED DRAINAGE PIPING SHALL BE SDR-35 PVC
DRAINAGE PIPING AND APPROVED FOR DIRECT BURIAL
UNDERGROUND DRAINAGE APPLICATION
SUCTION GRATE COVER SHALL
BE INSTALLED IN COMPLIANCE
WITH ASME A112.19.18 OR
APPROVED GRAVITY SYSTEM
PER R326.6.2
POOL DESIGNED IN
CONFORMANCE WITH ANSI/
APSP/ICC PER R326.3.2 NYSRC
NEW DRYWELL
REFER TO DETAILS
PROVIDE PRE-TREATMENT
BASIN AND PROVIDE
INSPECTION PORT TO DRYWELL
REFER TO DETAILS
6" DIA. SDR-35 PIPING TO
CONNECT FROM TRENCH
DRAIN TO INFILTRATION
SYSTEM
FLOATING POOL ALARM
SHALL BE PROVIDED
2"PVC FORCE MAIN FROM
POOL EQUIPMENT TO
MITIGATION SYSTEM FOR POOL
DRAW DOWN
4" OVERFLOW DRAIN TO RIPRAP
DISSIPATER
REFER TO DETAILS
MIN. 2% DRAINAGE SLOPE
TRENCH DRAIN
REFER TO DETAILS
ALL POOL COPING TO BE 14"
BLUESTONE COPING. PATIO TO
BE BLUESTONE SET IN
CONCRETE REFER TO DETAILS
AS PER NYSDEC GUIDELINES, INFILTRATION CHAMBERS SHALL BE
INSTALLED IN VIRGIN SOIL AND CANNOT BE INSTALLED ON
SLOPES GREATER THAN 15% OR IN FILL SETON GREATER THAN TOP
QUARTER OF DRYWELL. THREE FEET OF SEPARATION IS REQUIRED
BETWEEN GRAVEL BELOW THE INFILTRATORS AND IMPERVIOUS
OR MOTTLE SOIL LAYERS BELOW.
ELECTRICAL GROUNDING AND BONDING SHALL BE PROVIDED
AROUND PERIMETER OF POOL AND POOL EQUIPMENT BY
LICENSED ELECTRICAL CONTRACTOR. ALL POOL EQUIPMENT
SHALL BE GROUNDED AS REQUIRED BY MANUFACTURER
SPECIFICATIONS.
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 4
S-104
ENLARGED POOL PLAN
SCALE: 1/4" = 1'-0"
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
%%UFENCE NOTES:
1. FENCING SHALL BE 48" IN HEIGHT.
2. FENCE GATES SHALL BE 48"x48" AND
SWING OUTWARD DIRECTION AWAY
FROM HOT TUB AREA.
3. SPACE BETWEEN BOTTOM OF FENCE
BARRIER AND GROUND SHALL NOT
EXCEED 2".
4. FENCE POSTS SHALL BE SET IN 8"x42"
3,000 PSI CONCRETE PIERS.
5. FENCING SHALL BE BLACK ALUMINUM
OR STAINED PRESSURE TREATED
LUMBER.
6. FENCE STYLE SHALL BE APPROVED BY
OWNER PRIOR TO INSTALLATION.
7. FENCING SHALL BE INSTALLED IN
COMPLIANCE WITH NEW YORK STATE
BUILDING CODE REQUIREMENTS.
8. FENCING AND GATES SHALL BE
INSTALLED AND PERMITTED AS
REQUIRED BY LOCAL JURISDICTION.
42"
72" O.C.
3.5 " SPACING
1.
5"
8"
45" OR
MORE
48"
1.
5"
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 5
S-105
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
WOVEN WIRE FENCE (MIN. 14 12
POOL FILTERING SCHEMATIC
SCALE: NTS
LONGITUDINAL SECTION
SCALE: NTS
2"Ø P.V.C. BACK-FLUSH
(WASH) LINE FROM FILTER
PUMP
SHUT-OFF VALVE
FILTER
DIVERTER VALVE
DIVERTER
VALVE
CHEMICAL
FEEDER
(OPTIONAL)
3-WAY VALVES
ISOLATION VALVES
SAFETY VACUUM RELEASE SYSTEM
(ENTRAPMENT PROTECTION) AS
REQUIRED IN CONFORMANCE WITH
ASME 112.19.17
V
TEST VALVE
MAIN DRAIN(S) LINE
SHUT-OFF VALVE
GAS FIRED HEATER
(OPTIONAL)
POOL COPING
RETURN(S)
SKIMMER(S)
1-1/2"Ø P.V.C. FROM POOL SKIMMER,
FOR POOLS #1 & #2 2"Ø P.V.C. FROM
POOL SKIMMER, FOR POOLS #3, #4 & #5.
USE (RECOMMEND) TWO SKIMMERS
1-1/2"Ø P.V.C. RETURN FOR POOLS #1 &
#2, 2"Ø P.V.C. RETURN FOR POOLS #3, #4
#5, USE (RECOMMEND) TWO OUTLETS
%%UNOTE:
IF PROPOSED POOL IS TO BE HEATED, THE
ENGINEER STATES TO THE BEST OF HIS
KNOWLEDGE, BELIEF & PROFESSIONAL
KNOWLEDGE & EXPERIENCE THAT THESE
PLANS ARE IN COMPLIANCE WITH
APPLICABLE ENERGY CODES.
%%UNOTE:
ENTRAPMENT PROTECTION SHALL BE
PROVIDED/INSTALLED AS REQUIRED BY
NEW YORK STATE CODE.
PUMP SHALL BE
EQUIPPED WITH
SAFETY VACUUM
RELEASE SYSTEM
%%UNOTE:
FILL PIPE LINE TO POOL SHALL
BE PROVIDED BY HOSE BIB WITH
AN APPROVED AIR BREAK.
(NO AUTOMATIC FILL PIPE SHALL
BE USED)
SILT STOCK PILE DETAIL
SCALE: NTS
BENCH AND STEP OPTIONS:
1. UNDISTURBED EARTH MAY BE LEFT IN PLACE TO FORM THE STEPS OR BENCHES,
REINFORCING STEEL SHOULD BE PLACED AROUND THE STEP OR BENCH SHAPED EARTH (3"
CLEAR FROM EARTH).
2. THE EARTH MAY BE REMOVED AND BENCHES AND STEPS MAY BE FORMED OF SHOTCRETE
(GUNITE) WITHIN THE STRUCTURAL POOL SHELL. REINFORCING AT THE SURFACE OF THE
BENCHES AND STEPS IS OPTIONAL.
BENCH/STEPS
SEE OPTIONS
ABOVE
C
TABLE 1
5'-0"
6"
5'-0"
START ADD BARS
5'-0"
1ST ADD BARS
7'-0"
2ND ADD BARS
BASIC GRID #4 BARS
@ 12" O.C.
DECKING. SEE
PLANS
UNDER-WATER
LIGHT PER DETAIL
#10
STEEL BASKET IS NOT
REQUIRED
DRAIN PIPE SHALL NOT
ENCROACH INTO GUNITE SHELL
CIRCULATION DRAINS:
PROVIDE (2) ANTI-VORTEX CIRCULATION DRAINS PER PUMP.
COVERED WITH APPROVED A.S.M.E. ANTI-ENTRAPMENT
GRATES, THAT ARE HYDRAULICALLY BALANCED AND
SYMMETRICALLY PLUMBED THROUGH "T" FITTINGS. DRAINS
SHALL BE SEPARATED BY THREE FEET IN ANY DIMENSION.
TYP. FLOOR 6" THICK
MIN. SHOTCRETE
(GUNITE) W/ #4 BARS @
12" O.C. EACH
DIRECTION
ADD #4 @12 O.C.
LONGITUDINAL
@ TRANSITION
FOR EXP. SOILS
A.
INFLUENCE LINE
FOR FOOTING
SURCHARGE
A.
WATER SURFACE.
APPROX. 3" BELOW
BOND BEAM.
COPING
STONE WITH 12" - 1 12"
MORTARED JOINTS
1" - 2" MORTAR BED
4" - 6" CONCRETE
SLAB, REINFORCED IF
REQUIRED
6" COMPACTED
AGGREGATE
UNDISTURBED SOIL OR
COMPACTED SUBGRADE
PATIO DETAILS
SCALE: NTS
3'-10"
13'-9"
9'-4"
12'-5"
3'-10"
3'-0"
2'-0"
4'-0"
2'-0"
4'-1"
4'-3"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
15'-0"
4'-6"
4'-10"
5'-2"
5'-5"
6'-0"
6'-7"
7'-2"
7'-9"
8'-0"
11'-9"
DEGREE ANGLE OF SLOPE(S): FIRST 4.02°, SECOND 18.43°
POOL SHELL DEPTH DIMENSIONS
EXCAVATED AREA
4,300 CF / 159 CY
DEPTH OF POOL SECTION DETAIL
SCALE: NTS
FLOW
36" MIN.
FENCE POST.
SECTION VIEW
PERSPECTIVE VIEW
FLOW
FLOW
%%UCONSTRUCTION SPECIFICATIONS
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES.
POSTS SHALL BE STEEL EITHER "T" OR "U" TYPE OR HARDWOOD.
2. FILTER CLOTH TO BE TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED
EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE, 12 12 GAUGE, 6" MAXIMUM
MESH OPENING.
3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVER-LAPPED BY
SIX INCHES AND FOLDED. FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA
T140N, OR APPROVED EQUIVALENT.
4. PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT.
5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN "BULGES"
DEVELOP IN THE SILT FENCE.
4"
16"
MIN.
20"
MIN.
10' MAX. OC
HEIGHT OF
FILTER
16" MIN.
8"
MIN.
36" MIN. LENGTH
FENCE POSTS DRIVEN
MIN. 16" INTO
GROUND.
GAUGE W/ MAX. 6" MESH SPACING)
WITH SILT FILER CLOTH
WOVEN WIRE FENCE
(MIN. 14 12 GAUGE W/
MAX. 6" MESH
SPACING)
36" MIN. FENCE POST.
WOVEN WIRE FENCE
(MIN. 14 12 GAUGE W/
MAX. 6" MESH
SPACING) WITH
FILTER CLOTH
COMPACTED SOIL
EMBED FILTER
CLOTH A MIN. OF
6" IN GROUND.
UNDISTURBED
GROUND
SILT FENCE DETAIL
SCALE: NTS
LIGHT DETAIL
SCALE: NTS
NOTE:
1. INSTALL NO. 8 COPPER GROUND WIRE FROM LIGHT NICHE TO
BRASS CONDUIT TO POOL REBAR, OR NON-METALLIC CONDUIT
CAN BE USED WITH INSULATED NO. 8 COPPER WIRE INTERIOR
W/ APPROVED POTTING COMPOUND PER THE N.E.C.
2. SWIMMING POOL LIGHTING FIXTURES SHALL COMPLY WITH
APPLICABLE UNDERWRITERS' LABORATORIES REQUIREMENTS
FOR LIGHTING FIXTURES U.L STANDARD 676.
18" MIN.
PER. N.E.C.
4'-0" MIN.
8"
6"
MIN.
3"
CLR.
ELECTRICAL
'J' BOX
8" MIN. ABOVE DECK, WATER
LINE OR FLOOD LINE WHICH
EVER IS GREATER.
FIXTURE LENS
RECESSED LIGHT.
18" MIN.
LAP. TYP.
(2)#4 BARS EACH
WAY AROUND
NICHE.
N.E.C.
APPROVED
CONDUIT.
#8 COPPER
GROUND WIRE
SKIMMER DETAIL
SCALE: NTS
BOND BEAM
HORIZONTAL BARS MAY
BE OVER OR UNDER
VERTICAL BARS.
"
"
9 1/2"
TO
14"
"
"
3"
CLR
.
PRECAST COPING OR BRICK
3RD AND/OR 4TH
BAR LOCATION MAY
VARY TO PROVIDE 2
12" CLR. BETWEEN
PARALLEL BARS.
BRICK OR PRECAST
CONCRETE COPING
EXPANSION JOINT & SEALANT
REQ'D. FOR EXPANSIVE SOILS.
PER DETAIL #8
DECKING
PLUMBING MAY BE LOCATED
IN BOND BEAM LOWER
CORNER MAINTAIN 1" CLR. TO
REINF.
BOND BEAM PER TABLE NO. 1.
TILE
BOND BEAM/COPING DETAIL
SCALE: NTS
INTENDED TROUGH SIZE IS 1'-6" WIDE
COORDINATE FINAL SIZE WITH POOL
AUTOCOVER PRIOR TO INSTALLATION
APPROXIMATE LINE OF GRADE
#4 REBAR 12" O.C
HORIZONTAL
TIE TO VERTICAL
TOP OF COPING AND
POOL WATER
LEVEL REFER TO SITE
PLAN FOR ELEVATIONS
TROUGH MUST BE SHOT
MONOLITHICALLY WITH POOL
#4 REBAR 12" O.C
BACKFILL SHALL BE
COMPACTED TO 95%
MODIFIED PROCTOR
VALUE
#4 REBAR 12" O.C
TIE TO POOL WALL
REINFORCING BARS
1'-4"
8"
2'-2" MIN.
1"
1'-4"
POOL COVER TROUGH DETAIL
SCALE: NTS
SPA DETAIL
SCALE: NTS
1" MIN. CLR.
AROUND
ALL PIPES.
6" DAM - LAP INTO SPA
REINF.
12" DAM - LAP INSIDE BARS INTO SPA REINF.
- LAP OUTSIDE BARS INTO POOL REINF.
DAM WALL
HORIZ. BAR
LAP SPLICE:
CIRCULATION DRAINS:
PROVIDE (2) ANTI-VORTEX CIRCULATION DRAINS PER PUMP.
COVERED WITH APPROVED A.S.M.E. ANTI-ENTRAPMENT
GRATES, THAT ARE HYDRAULICALLY BALANCED AND
SYMMETRICALLY PLUMBED THROUGH "T" FITTINGS. DRAINS
SHALL BE SEPARATED BY THREE FEET IN ANY DIMENSION.
24"
LAP
24" MIN.
LAP
2"
2"
9" & LARGER
6"-8"
4"
4'-0" MAX.
6"
3"
6"
THICK
30' MAX.
FREESTANDING
EQ.
6"
MIN.
EQ.
4"
(4)#4 BARS
#4 BARS
@12" O.C.
EA.WAY
WATER
LINE
#4 BARS @
12" O.C. EA.
WAY
(4)#4 BARS
#4 BARS
@12" O.C.
EA.WAY
WATER
LINE
24" MIN. LAP INTO
SPA FLOOR OR
POOL WALL
WATER LINE
SPA LIGHT
REINFORCING REFER
TO LIGHT SECTION
NOTE:
SPA AIR-LINE MAY BE
LOOPED INTO SPA
BOND BEAM.
MAINTAIN 1" CLR. TO
REINF.
BOND BEAM PER
TABLE NO. 1 &
DETAIL #12
NO DECK/HIGH EXP.
C
(4) #4 BARS.
E.F.P.
D
R
C
VERTICAL
STEEL
3'0"
1'-0"
3'6"
1'-0"
4'0"
1'-0"
4'6"
1'-0"
5'0"
1'-6"
5'6"
2'-0"
6'0"
2'-6"
6'6"
3'-0"
7'0"
3'-6"
7'6"
4'-0"
8'0"
4'-6"
8'6"
5'-0"
3"
3"
4"
5"
5"
5"
6"
7"
8"
8 12"
9"
9"
#4 @ 12"
#4 @ 6"
SLOPE EARTH SURFACE 14" PER
FOOT OR SLOPE DECKING
18" TO 14"
PER FOOT AWAY FROM POOL.
NOTE:
BOND BEAM HORIZONTAL BARS MAY BE
OVER OR UNDER VERTICAL BARS. TYPICAL
INCLUDING ALL SPECIAL DETAILS.
UNDISTRURBED SOIL.
1500 PSF MIN.
BEARING VALUE.
DRAIN
ADDITIONAL BARS BEGIN AT 5'-0" FROM THE TOP OF THE POOL WALL
(RAISED OR NOT RAISED).
* IF POOL WALL HEIGHT DOES NOT EXCEED 5'-0" THEN NO
ADDITIONAL BARS ARE REQUIRED. (DOES NOT APPLY TO SUPPLEMENT
DETAILS)
30" MAX.
FREESTANDING
OR
NON-APPROVED
FILL
3"
CLR.
±3"
STRAIGHT WALL
8'-0" MAX.
DEPTH
5'-0"
START ADDITIONAL BARS*
3" CLR.
TYP.
24" MIN.
EXTEND WALL
REINF. INTO FLOOR
(30" MIN. FOR TABLE 5G)
6"
'C'
RADIUS-R
(SEE TABLE #1)
COPING
BOND BEAM
SEE DETAIL #1 & #12.
APPROVED SEALANT
REQUIRED W/ EXPANSIVE
SOIL.
INDICATES TYPICAL
RADIUS
'D' IS DISTANCE DOWN
FROM TOP OF POOL WALL.
'C' SHOTCRETE COVER TO
BE CHANGED UNIFORMLY.
SEE TABLE 1
ACTUAL DIG LINE MAY
VARY, LOCATE STEEL 3"
CLR FROM EARTH
VERTICAL STEEL. SEE
TABLE 1
HORIZONTAL STEEL #4
BARS @ 12" O.C.
STANDARD WALL REINFORCEMENT DETAIL
SCALE: NTS
FENCE/GATE DETAILS
SCALE: NTS
48" GATE WIDTH
PROVIDE LATCH
MECHANISM AT ALL GATE
ENTRY TO POOL AREA
1.5"
45" OR MORE
48"
1.5"
3.5 " SPACING
PROVIDE SELF-LATCHING GATE IN
COMPLIANCE WITH RCNYS 326.4.2.7.1&2
LATCH TO BE SET AT 54" ABOVE GRADE
AND ON POOL SIDE OF GATE
GATE SHALL BE SECURELY
LOCKED WITH A KEY OR
COMBINATION LOCK
SUFFICIENT TO PREVENT
ACCESS TO SWIMMING POOL
WHEN THE SWIMMING POOL IS
NOT IN USE OR SUPERVISED
GATE SHALL OPEN OUTWARD
AWAY FROM POOL
54"
NOTE:
STOCKPILE SHALL BE COVERED ENTIRELY BY AN
ANCHORED PLASTIC COVER OR SEEDED
PLASTIC COVER OR APPROVED
STABILIZED COVER
STOCKPILE
MATERIAL
SILT FENCE
(SEE DETAIL)
5"
LEVEL TOP OF GUNITE
WI GROUT & PLACE #15
FELT OR 4 MIL.
VISQUEEN ON TOP.
DECKING
COPING
SKIMMER
COVER
BEND BOND
BEAM UNDER
SKIMMER
(2)#4 BARS
(2)#4 'Z'
BARS
5" MIN.
AROUND ALL
SECTION AT SKIMMER
PLAN AT SKIMMER
24"
MIN.
LAP
3"
5" MIN.
TYPICAL.
3" CLR.
TYPICAL
3" CLR.
TYPICAL
POOL
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
METHOD: TR-55
PROPOSED CURVE NUMBER (CN): 98
PROPOSED CURVE NUMBER (CN): DRIVEWAYS/ROOFS
EXISTING CURVE NUMBER (CN): 75
SOIL TYPE: UpC URBAN LAND-PAXTON COMPLEX 8-15%
HYDROLOGIC SOIL: GROUP B
SOIL SURVEY WESTCHESTER COUNTY: PnB- 0.6-2.0 IN/HR
STORM WATER RETENTION NOTES
CURVE NUMBER (CN): RESIDENTIAL
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 6
S-106
CULTEC RECHARGER® 330XLHD PRODUCT SPECIFICATIONS
GENERAL
CULTEC RECHARGER 330XLHD CHAMBERS ARE DESIGNED FOR UNDERGROUND
STORMWATER MANAGEMENT. THE CHAMBERS MAY BE USED FOR RETENTION, RECHARGING,
DETENTION OR CONTROLLING THE FLOW OF ON-SITE STORMWATER RUNOFF.
CHAMBER PARAMETERS
1. THE CHAMBERS SHALL BE MANUFACTURED BY CULTEC, INC.
2. THE CHAMBER SHALL BE VACUUM THERMOFORMED OF HIGH MOLECULAR WEIGHT HIGH
DENSITY POLYETHYLENE (HMWHDPE) WITH A BLACK INTERIOR AND BLUE EXTERIOR.
3. THE CHAMBER SHALL BE ARCHED IN SHAPE.
4. THE CHAMBER SHALL BE OPEN-BOTTOMED.
5. THE CHAMBER SHALL BE JOINED USING AN INTERLOCKING OVERLAPPING RIB METHOD.
CONNECTIONS MUST BE FULLY SHOULDERED OVERLAPPING RIBS, HAVING NO SEPARATE
COUPLINGS OR SEPARATE END WALLS
6. THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC RECHARGER 330XLHD SHALL BE
30.5 INCHES TALL, 52 INCHES WIDE AND 8.5 FEET LONG. THE INSTALLED LENGTH OF A
JOINED RECHARGER 330XLHD SHALL BE 7 FEET.
7. MAXIMUM INLET OPENING ON THE CHAMBER ENDWALL IS 24 INCHES HDPE.
8. THE CHAMBER SHALL HAVE TWO SIDE PORTALS TO ACCEPT CULTEC HVLV® FC-24 FEED
CONNECTORS TO CREATE AN INTERNAL MANIFOLD. THE NOMINAL DIMENSIONS OF
EACH SIDE PORTAL SHALL BE 10.5 INCHES HIGH BY 11.5 INCHES WIDE. MAXIMUM
ALLOWABLE OUTER DIAMETER (O.D.) PIPE SIZE IN THE SIDE PORTAL IS 11.75 INCHES.
9. THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC HVLV FC-24 FEED CONNECTOR
SHALL BE 12 INCHES TALL, 16 INCHES WIDE AND 24.2 INCHES LONG.
10. THE NOMINAL STORAGE VOLUME OF THE RECHARGER 330XLHD CHAMBER SHALL BE 7.459
FT³ / FT - WITHOUT STONE. THE NOMINAL STORAGE VOLUME OF A JOINED RECHARGER
330XLHD SHALL BE 52.213 FT³ / UNIT - WITHOUT STONE.
11. THE NOMINAL STORAGE VOLUME OF THE HVLV FC-24 FEED CONNECTOR SHALL BE 0.913
FT³ / FT - WITHOUT STONE.
12. THE RECHARGER 330XLHD CHAMBER SHALL HAVE FIFTY-SIX DISCHARGE HOLES BORED
INTO THE SIDEWALLS OF THE UNIT'S CORE TO PROMOTE LATERAL CONVEYANCE OF
WATER.
13. THE RECHARGER 330XLHD CHAMBER SHALL HAVE 16 CORRUGATIONS.
14. THE ENDWALL OF THE CHAMBER, WHEN PRESENT, SHALL BE AN INTEGRAL PART OF THE
CONTINUOUSLY FORMED UNIT. SEPARATE END PLATES CANNOT BE USED WITH THIS
UNIT.
15. THE RECHARGER 330XLRHD STAND ALONE UNIT MUST BE FORMED AS A WHOLE
CHAMBER HAVING TWO FULLY FORMED INTEGRAL ENDWALLS AND HAVING NO
SEPARATE END PLATES OR SEPARATE END WALLS.
16. THE RECHARGER 330XLSHD STARTER UNIT MUST BE FORMED AS A WHOLE CHAMBER
HAVING ONE FULLY FORMED INTEGRAL ENDWALL AND ONE PARTIALLY FORMED
INTEGRAL ENDWALL WITH A LOWER TRANSFER OPENING OF 14 INCHES HIGH X 34.5
INCHES WIDE.
17. THE RECHARGER 330XLIHD INTERMEDIATE UNIT MUST BE FORMED AS A WHOLE
CHAMBER HAVING ONE FULLY OPEN ENDWALL AND ONE PARTIALLY FORMED INTEGRAL
ENDWALL WITH A LOWER TRANSFER OPENING OF 14 INCHES HIGH X 34.5 INCHES WIDE.
18. THE RECHARGER 330XLEHD END UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING
ONE FULLY FORMED INTEGRAL ENDWALL AND ONE FULLY OPEN END WALL AND
HAVING NO SEPARATE END PLATES OR END WALLS.
19. THE HVLV FC-24 FEED CONNECTOR MUST BE FORMED AS A WHOLE CHAMBER HAVING
TWO OPEN END WALLS AND HAVING NO SEPARATE END PLATES OR SEPARATE END
WALLS. THE UNIT SHALL FIT INTO THE SIDE PORTALS OF THE RECHARGER 330XLHD AND
ACT AS CROSS FEED CONNECTIONS.
20. CHAMBERS MUST HAVE HORIZONTAL STIFFENING FLEX REDUCTION STEPS BETWEEN THE
RIBS.
21. THE CHAMBER SHALL HAVE A 6 INCH DIAMETER RAISED INTEGRAL CAP AT THE TOP OF
THE ARCH IN THE CENTER OF EACH UNIT TO BE USED AS AN OPTIONAL INSPECTION
PORT OR CLEAN-OUT.
22. THE UNITS MAY BE TRIMMED TO CUSTOM LENGTHS BY CUTTING BACK TO ANY
CORRUGATION.
23. THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2015 CERTIFIED FACILITY.
24. MAXIMUM ALLOWED COVER OVER TOP OF UNIT SHALL BE 12 FEET
25. THE CHAMBER SHALL BE DESIGNED TO WITHSTAND TRAFFIC LOADS WHEN INSTALLED
ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS.
STORM WATER CONSTRUCTION NOTES
1.
THE STORM WATER RETENTION SYSTEM SHALL NOT BE CONNECTED FOR USE UNTIL
CONSTRUCTION IS COMPLETE AND SITE IS STABILIZED.
EXISTING DRAINAGE SYSTEM NOTES
1. THE CURRENT SITE DOES NOT HAVE A MEANS OF STORM WATER RETENTION.
2. A NEW STORM WATER SYSTEM IS PROPOSED FOR ADDITIONAL SITE COVERAGE.
CULTEC NO. 66™ WOVEN GEOTEXTILE
GENERAL
CULTEC NO. 66™ WOVEN GEOTEXTILE IS UTILIZED AS AN
UNDERLAYMENT TO PREVENT SCOURING CAUSED BY WATER
MOVEMENT WITHIN THE CULTEC CHAMBERS AND FEED CONNECTORS
UTILIZING THE CULTEC MANIFOLD FEATURE.
GEOTEXTILE PARAMETERS
1. THE GEOTEXTILE SHALL BE PROVIDED BY CULTEC, INC. OF
BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832)
2. THE GEOTEXTILE SHALL BE BLACK IN APPEARANCE.
3. THE GEOTEXTILE SHALL HAVE A TENSILE STRENGTH OF 315 LBS
(1.40KN) PER ASTM D4632 TESTING METHOD.
4. THE GEOTEXTILE SHALL HAVE A TENSILE ELONGATION
RESISTANCE OF 15% PER ASTM D4632 TESTING METHOD.
5. THE GEOTEXTILE SHALL HAVE A MULLEN BURST RESISTANCE OF
600PSI (4138 KPA) PER ASTM D3786 TESTING METHOD.
6. THE GEOTEXTILE SHALL HAVE A TEAR RESISTANCE OF 115 LBS (0.51
KN) PER ASTM D4533 TESTING METHOD.
7. THE GEOTEXTILE SHALL HAVE A PUNCTURE RESISTANCE OF 150 LBS
(0.66 KN) PER ASTM D4833 TESTING METHOD.
8. THE GEOTEXTILE SHALL HAVE A CBR PUNCTURE RESISTANCE OF 900
LBS (4.00 KN) PER ASTM D6241 TESTING METHOD.
9. THE GEOTEXTILE SHALL HAVE A UV RESISTANCE OF 70% @ 500 HRS.
PER ASTM D4355 TESTING METHOD.
10. THE GEOTEXTILE SHALL HAVE A PERMITTIVITY RATING OF 0.05
SEC-1 PER ASTM D4491 TESTING METHOD.
11. THE GEOTEXTILE SHALL HAVE A WATER FLOW RATING OF 4 GPM/
FT2 (160 LPM/M2) PER ASTM D4491 TESTING METHOD.
12. THE GEOTEXTILE SHALL HAVE A PERCENT OPEN AREA OF <1% PER
CW-02215 TESTING METHOD.
13. THE GEOTEXTILE SHALL HAVE AN APPARENT OPENING SIZE OF 40
US STD. SIEVE (0.425 MM) PER ASTM D4751 TESTING METHOD.
14. THE GEOTEXTILE SHALL CONSIST OF A 100% HIGH-TENACITY, SILT-
FILM POLYPROPYLENE YARNS.
POST STORM WATER MANAGEMENT MAINTENANCE
NOTES:
1.
SYSTEM SHOULD BE INSPECTED PRIOR TO SYSTEM
OPERATION.
2.
STORMWATER INSPECTION PORTS ARE TO BE MONITORED
ON A ROUTINE BASIS.
3.
ALL GUTTERS AND DOWNSPOUT SYSTEMS LEADING TO
STORMWATER RETENTION AREAS SHOULD BE MAINTAINED
FREE OF DEBRIS AND CLEANED ON A ROUTINE BASIS.
4.
OVERFLOW PORTS SHOULD BE MONITORED.
5.
SYSTEM RECOMMENDED TO BE CLEANED :
5.1. WHERE SYSTEM IS EXPERIENCING SILT AND OR SOIL
BUILD UP AS NOTED THROUGH THE INSPECTION PORT OR
PRETREATMENT HOOD.
5.2. IF OUTLET PIPING IS NOTED TO BE CLOGGED AND
WATER DISCHARGE IS NOTED FROM OVERFLOW SURCHARGE
PIPING
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
STORMWATER MANAGEMENT CALCULATIONS:
STATE: NEW YORK
LONGITUDE: 73.903 WEST
LATITUDE: 41.220 NORTH
10 YEAR/24HR - 5.12 INCHES/HR
SOURCE-
NORTHEAST REGIONAL CLIMATE CENTER (NRCC)
NATURAL RESOURCES CONSERVATION SERVICE (NRCS)
EXTREME PRECIPITATION TABLE
STORM WATER RETENTION MATERIAL
NO.
AREA
(SF)
CHAMBER
VOLUME
CHAMBERS
(QTY)
STONE
VOID
STONE
VOLUME
DW-1
2,089
344.12
12.52
40%
cubic
feet
cubic
yards
*12" STONE ABOVE CROWN, 12" STONE FOUNDATION DEPTH. 12" SIDE COVER
COMPACTED BACKFILL SOIL
6" SEWER & DRAIN
RISER PIPE (LENGTH AS REQUIRED)
6" DRAIN PIPE
CRUSHED STONE
PART # 101 6" SPEE-D BASIN
NDS POP UP EMITTER
PART # 620 OR APPROVED EQUAL
VARIE
S
POP UP EMITTER
SCALE: NTS
TRENCH DRAIN DETAIL
SCALE: NTS
DIAGRAM
DIAGRAM
END
DRAIN
DIAGRAM
COMPACTE
D
SOI
L
FINISH
GRADE
%%UTRENCH DRAIN NOTES:
1. TRENCH DRAINS SYSTEM SHALL BE POLYLOK HEAVY DUTY TRENCH DRAIN PL-90860 OR APPROVED
EQUAL
2. TRENCH DRAIN SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS FOR H-20 LOADING.
3. TRENCH DRAIN SYSTEM SHALL BE SET IN 6" CONCRETE SURROUNDING BASE.
4. CONCRETE TO BE MINIMUM 5,000 AIR ENTRAINED CONCRETE MIX.
5. TRENCH DRAIN SHALL HAVE MINIMUM QTY (4) #4 VERTICAL REBARS INSTALLED PER EACH TRENCH
DRAIN SECTION. REBAR SHALL BE CROSS TIED AS PER DETAILS.
6. PROVIDE MINIMUM OF 8" COMPACTED BASE OF 3
4" WASHED GRAVEL BELOW TRENCH DRAIN
INSTALLATION
6" MIN.
6" MIN.
6" MIN.
WIRE TIE TOP AND BOTTOM TO
SET
ELEVATION AND TO PREVENT
FLOATING
WIRE TIE #3 REBAR
LOOPS
TO VERTICAL #4
REBAR
WIRE TIE
ALL
INTERSECTIONS WHERE
#3 REBAR LOOPS MEET
#4HORIZONTAL
REBAR
#4 HORIZONTAL REBAR TO
BE
TIED CONTINUOUS FOR
ENTIRE
LENGTH OF TRENCH DRAIN TYPE
PLCS
.
#3 REBAR LOOPS 4
PERSECTION 2 ON
EACH
END 2 EVENLY
SPACED
CROSS TIE REBAR AT ALL
JOINTS
DEPTH OF
VERTICAL
REBAR TO PROVIDE
STABLE FOOTING
AND
TO PREVENT
PULLOUT
BUILDING
FOUNDATION
DOWN TURNED PIPE
ELBOW FITTING TO
PREVENT
CONVEYANCE OF
FLOATABLES O
DRYWELL
24 DIA."x24"
DEEP SUMP
MESH
SCREEN
TO DRYWELL
SEE DRYWELL
DETAILS
ACCESS LID
(24" MIN)
FROM TRENCH DRAIN/
OR LEADER
INSPECTION PORT DETAIL
SCALE: NTS
RECHARGER 330XLHD
HEAVY DUTY CHAMBER
MINIMUM 95% COMPACTED
FILL
PAVEMENT OR FINISHED GRADE
CULTEC NO. 410 NON-WOVEN GEOTEXTILE AROUND STONE. TOP
AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN
PREFERENCE
6" MIN.
30.5"
12" MIN.
12.0' MAX.
COVER DEPTH
58" MIN.
CENTER TO CENTER
52"
12" MIN.
10.0" MIN. FOR PAVED
12.0" MIN. FOR UNPAVED
HVLV FC-24 FEED CONNECTOR
WHERE SPECIFIED
1-2 INCH WASHED, CRUSHED
STONE SURROUNDING CHAMBERS
CULTEC NO. 4800 WOVEN GEOTEXTILE TO BE PLACED BENEATH INTERNAL MANIFOLD
FEATURE AND BENEATH ALL INLET/OUTLET PIPES (FOR SCOUR PROTECTION)
PROJECT ENGINEER OF RECORD OR GEOTECHNICAL CONSULTANT IS RESPONSIBLE FOR ENSURING THAT THE
REQUIRED BEARING CAPACITY OF SUB-GRADE SOILS HAS BEEN MET
10"
MIN
NEENAH FOUNDRY MODEL R-5900-A
(OR EQUAL) HEAVY DUTY FRAME AND
LID
PAVEMENT OR
FINISHED GRADE
12.0" SDR-35 / SCH. 40 PVC COLLAR
FIELD PLACED CLASS "C" CONCRETE
MAINTAIN 6.0" [150 mm] CLEARANCE BETWEEN
HEAVY DUTY LID AND PVC CLEAN-OUT CAP
6.0" [150 mm] SDR-35 / SCH. 40 PVC ENDCAP
CLEAN-OUT ADAPTER W/ SCREW-IN CAP
6.0" [150 mm] SDR-35 / SCH. 40 PVC RISER
6.0" [150 mm] SDR-35 / SCH. 40 PVC COUPLING
TRIM CHAMBER INSPECTION PORT KNOCK-OUT TO
MATCH O.D. OF 6.0" [150 mm] INSPECTION PORT PIPE
6.0" [150 mm] SDR-35 / SCH 40 PVC
(INSERTED 8" [200 mm] INTO CHAMBER)
DRYWELL PRETREATMENT DETAIL
SCALE: NTS
DRYWELL DETAILS
SCALE: NTS
S
N
G
I
S
E
D
L
A
E
R
S
E
R
IT IS A VIOLATION OF STATE LAW FOR ANY PERSON
UNLESS DIRECTED BY A REGISTERED ARCHITECT
OR PROFESSIONAL ENGINEER TO ALTER THIS ITEM
IN ANY WAY.
PROJECT:
DRAWING TITLE:
NOTES:
SEAL &
SIGNATURE:
www.ResReal.com
(914)-330-7712
2875 Route 35
Katonah, NY 10536
JMS ENGINEERING SERVICES, PC
JOHN M. SCAVELLI PE LICENSE # 095178
S
N
G
I
S
E
D
L
A
E
R
S
E
R
ISSUE:
DATE:
BY:
CHECKED:
APPROVED:
%
%UPROFILE
NOTE:
PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED
CONSTRUCTION ENTRANCE AND PUBLIC R.O.W.
50' OR GREATER AS REQ'D.
12' (MIN)
10'(MIN.)
10'(MIN.)
50' OR GREATER AS REQ'D.
PUBLIC ROW
6"(MIN.)
EXST.
FILTER CLOTH
(MIRAFI 140N)
EXST.
GROUND
EXST.
GROUND
R=25
R=25
19 ARROWCREST DRIVE
CROTON ON HUDSON, NY
PROPERTY INFORMATION:
PREPARED BY: JMS ENGINEERING SERVICES, PC
PROJECT LOCATION: 19 ARROWCREST DRIVE
PROJECT TOWN: CROTON ON HUDSON
BUILDING DEPARTMENT: CROTON ON HUDSON
PROPERTY IDENTIFICATION: 67.15-1-42
OCCUPANCY: SINGLE FAMILY DWELLING
ZONING CODE: RA-40
JMS
JMS
10/10/2024
JMS
SITE IMPROVEMENTS
SHEET 7
S-107
TO THE BEST OF MY KNOWLEDGE, BELIEF AND
PROFESSIONAL JUDGMENT OF THE UNDERSIGNED, THE
PLANS AND SPECIFICATIONS DEPICTED ON THESE
DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE
PROVISIONS OF THE NEW YORK STATE UNIFORM FIRE
PREVENTION AND BUILDING CODE AND THE NEW
YORK STATE ENERGY CONSERVATION CONSTRUCTION
CODE CURRENTLY IN EFFECT.
TO ORDER HARDCOPY
SCAN QR CODE
BELOW:
POOL AUTOCOVER DETAIL
SCALE: NTS
T- COUPLING
MAIN DRAINS
DUAL DRAIN NOTES:
DUAL DRAINS SHALL BE INSTALLED AT DEEP END OF POOL.
IN COMPLIANCE WITH R326.6.4 CIRCULATION SYSTEM SHALL HAVE
A MINIMUM OF TWO SUCTION OUTLET DRAINS. A MINIMUM
HORIZONTAL DISTANCE OF 3FT SHALL SEPARATE DRAIN OUTLETS.
OUTLETS SHALL BE PIPED SO THAT WATER IS DRAWN THROUGH
THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-
PROTECTED LINE TO THE PUMPS SYSTEM.
3' MINIMUM DISTANCE
6' MAXIMUM DISTANCE
2' POOL BASE
LINE
DPIT
SUMP
TOP TRIM OF STONE BERM
VEHICLE ENTRANCE
6" WASH STONE
SF
SF
SF
SF
2:1
2:1
SILT
FENCE
"CONCRETE WASHOUT" SIGN
(SEE NOTE 2)
SIL
T
FENCE
ANCHOR PLASTIC LINER
WITH #57 STONE BERM
PIT SUMP
VEHICLE ENTRANCE
@2% SLOPE
2:1
KEY IN REMOVABLE
LINING
10 MIL. PLASTIC LINING
SIL
T
FENCE
ANCHOR PLASTIC LINER
WITH #57 STONE BERM
PIT SUMP
2:1
10 MIL. PLASTIC LINING
SIL
T
FENCE
CONCRETE
WASHOUT
0.5" LAG
SCREWS
PLYWOOD 48"x24"
PAINTED
WHITE
BLACK LETTERS
6" HEIGHT
3"x3"x8'
WOOD POSTS
SECTION B-B
SECTION A-A
PLAN VIEW
"CONCRETE WASHOUT" SIGN DETAILS
SIDE VIEW
FRONT VIEW
A
A
B
B
%
%UNOTES:
1. ACTUAL LAYOUT TO BE DETERMINED IN FIELD.
2. THE "CONCRETE WASHOUT" SIGN SHALL BE INSTALLED WITHIN 30
FEET OF THE TEMPORARY CONCRETE WASHOUT FACILITY.
3. PIT CAPACITY IS MINIMUM OF 6 CUBIC FEET PER 10 CUBIC YARDS OF
CONCRETE.
2'
2'
1'
2'
6'
2'
25' MINIMUM
15'
1'
1'
1'
2'
2'
1'
2'
6'
2'
1'
2'
2'
20'
1'
1'
1'
1'
1'
3'
3'
2'
4'
2" DRAIN
POOL COPING
POOL WALL
RECESSED POOL
COVE
R
RECESSED POOL COVER
PROVIDE COVERSTAR POOL
COVER OR APPROVED
EQUA
L
2'-8"
2"
16"
6"
6"
12"
14"
ELECTRICAL GROUNDING DETAIL
SCALE: NTS
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS,
CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY.
4.
ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT
MUST BE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED
ACCURATE.
NDS SQUARE POLYOLEFIN
GRATE WITH U.V. INHIBITORS
OR APPROVED EQUAL
SLOPE TO DRAIN
COMPACTED SOIL
6" SEWER AND DRAIN RISER PIPE
(LENGTH AS REQUIRED) OR
APPROVED EQUAL
NDS #101 SPEE-D
BASIN OR
APPROVED EQUAL
SEWER AND
DRAIN PIPE
INVERT
ELEVATION
CRUSHED
STONE
SLOPE TO DRAIN
V
A
R
I
E
S
SECTION
YARD DRAIN DETAIL
SCALE: NTS
GROUNDING ELECTRODE
CONDUCTOR
NON- METALLIC
PROTECTIVE SLEEVE
CONNECTION LISTED
FOR THE PURPOSE
4 AWG OR LARGER BARE
COPPER CONDUCTOR OR
STEEL REINFORCING BAR
OR ROD NOT LESS THAN
1/2" IN DIAMETER, AT
LEAST 20-FT LONG
2"
MIN.
20 FT. OR MORE
FOUNDATION IN
DIRECT CONTACT
WITH THE EARTH
LICENSED ELECTRICAL CONTRACTOR SHALL
PROVIDE
AND INSTALL GROUNDING AND BONDING
FOR
ELECTRICAL SYSTEM AS REQUIRED BY E3608,
E3609
TEMPORARY CONSTRUCTION ENTRANCE DETAIL
SCALE: NTS
CONSTRUCTION WASHOUT DETAIL
SCALE: NTS
STORM WATER MANAGEMENT MAINTENANCE SCHEDULE & PROCEDURES
SCALE: NTS
CONSTRUCTION SPECIFICATIONS
1. STONE SIZE - USE 3" STONE (NYSDOT ITEM #623.11 SIZE DESIGNATION #2, OR RECLAIMED OR RECYCLED
CONCRETE EQUIVALENT.
2. LENGTH - NOT LESS THAN 50" FEET
3. THICKNESS - NOT LESS THAN SIX (6) INCHES.
4. WIDTH - TWELVE (12) FOOT MINIMUM. BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR
EGRESS OCCURS. TWENTY-FOUR (24) FOOT IF SINGLE ENTRANCE TO SIGHT.
5. FILTER CLOTH - WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE.
6. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES
SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL. A MOUNTABLE BERM WITH 5:1 SLOPES
WILL BE PERMITTED
7. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING
OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OFWAY. ALL SEDIMENT SPILLED, DROPPED, WASHED OR
TRACTED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY.
8. WHEN WASHING IS REQUITED. IT SHALL BE DONE ON A AREA STABILISED WITH NSTONE AND WHICH
DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE.
9. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN.
PLAN VIEW
POOL DRAIN DETAIL
SCALE: NTS