133 Maple St - 3 Car Garage Plans
map survey
3 pages
Meeting: portal event 1023 (no meeting page on file)
Agenda item: New Business — Franzoso, Mark, owner---133 Maple Street-Located in a RB 2-family Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.5 Block 1 Lot 51. Request for a height variance from Village Zoning Code Section 230-40A(1)(a) for a proposed addition to an existing garage.
Map / plans, 3 pages. Attached to agenda item: “New Business — Franzoso, Mark, owner---133 Maple Street-Located in a RB 2-family Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.5 Block 1 Lot 51. Request for a height”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
133 Maple St - ZBA Application 2.25.25 Redacted
133 Maple Street Aerial
133 Maple Street DRAFT Resolution 2.25.25
Extracted text
·
·
·
·
·
·
·
·
·
·
·
·
·
·
NEW 3 CAR GARAGE
± 1,500.00 S.F
NEW ASPHALT
DRYWAY
EXISTING 2 CAR GARAGE
NEW 3 CAR GARAGE
C.H. 9'-0"
31' - 6"
48'-0"
5' - 0"
9' - 0"
9' - 0"
4' - 6"
9' - 0"
5' - 0"
4' - 6"
5' - 0"
LOT LINE
LOT LINE
LOT LINE
NEW GARAGE DOOR
NEW GARAGE DOOR
NEW GARAGE DOOR
NEW ASPHALT DRIVEWAY
EXIST. ASPHALT
DRIVEWAY
EXIST. GARAGE DOOR
EXIST. GARAGE DOOR
16'-6"
13'-6"
16'-6"
UP
20'-6"
48'-6"
NEW STORAGE AREA
± 1,400.00 S.F
48'-0"
31'-6"
DN
Ground Floor
0' - 0"
Storage
10' - 0"
Exist. Roof
22' - 0"
New Ridge Roof
20' - 0"
NEW ASPHALT/FIBERGLASS ROOF SHINGLES
OVER 15# BUILDING PAPER ON 5/8" EXTERIOR
PLYWOOD SHEATHING ON NEW 2X10 ROOF
RAFTERS @ 16" O.C.. PROVIDE ICE & WATER
SHIELD BEHIND FASCIAS/UP ROOF SLOPE 2'-0"
MIN.
NEW 2"x10" RIDGE TO BE ANCHOR
INTO NEW (2) 1 3/4" X 11 7/8"
LAMINATED WOOD LVL
NEW SIDING TBD BY OWNER
NEW 3 CAR GARAGE
EXIST. ROOF
EXIST. 2 CAR GARAGE
NEW 2"X10" R.R. @ 16" O.C.
W/ TYP. TIES.
NEW ANDERSEN WINDOW
SEE SCHEDULE SHEET FOR
INFO.
NEW 2"x10" RIDGE TO BE ANCHOR
INTO NEW (2) 1 3/4" X 11 7/8"
LAMINATED WOOD LVL
NEW 2"X10" R.R. @ 16" O.C.
W/ TYP. TIES.
NEW ANDERSEN WINDOW
SEE SCHEDULE SHEET FOR
INFO.
1' - 6"
3' - 0"
3' - 5 1/2"
NEW 6" STUD WALL
NEW #5 BARS VERTICAL @ 24" O.C.
NEW 6" Ø FTG DRAIN
WASHED GRAVEL CONTINUOS
PROVIDE DRAINAGE PROTECTION
BOARD & DAMP PROOFING AT ALL
NEW FOUNDATION WALLS
GRADE VARIES (TYP)
5" FINISHED FLOOR
6X6X10X10 WW
4,000 PSI. CONCRETE
NEW POURED CONCRETE
FOUNDATION 3,000 PSI.
·
·
·
·
·
·
·
NEW ASPHALT/FIBERGLASS ROOF SHINGLES
OVER #15 BUILDING PAPER ON 5
8" EXTERIOR
PLYWOOD SHEATHING ON A NEW 2"X10"
R.R. @ 16" O.C. PROVIDE ICE & WATER
SHIELD BEHIND FASCIAS/UP ROOF.
W21x100 "I" steel beam ASTM
A992 Gr. 50 (TO BE VERIFY BY A
STRUCTURAL ENGINEER)
EXIST. "I" STEEL BEAM
NEW "I" STEEL BEAM
NEW "I" STEEL BEAM
W21x100 steel beam ASTM A992 Gr. 50
(TO BE VERIFY BY A STRUCTURAL ENGINEER)
NEW (2) 1 3
4" X 11 7
8" LAMINATED LVL WOOD BEAM
NEW 2"x10" VALLEY RAFTER
NEW 2"x10" VALLEY RAFTER
NEW 2"X10" WOOD RIDGE
NEW 2"x10" VALLEY RAFTER
NEW 2"x10" VALLEY RAFTER
NEW 2"X10" WOOD RIDGE
W21x100steel beam ASTM A992 Gr. 50
(TO BE VERIFY BY A STRUCTURAL ENGINEER)
NEW 2"X12" F.J. @ 16" O.C.
W/ TYP. FRAMING CLIPS.
NEW 2"X10" VALLEY RAFTER
NEW 2"X10" VALLEY RAFTER
NEW (2) 2"X10" WOOD BEAM
NEW ANDERSEN D.H WINDOW
NEW ANDERSEN D.H WINDOW
NEW ANDERSEN D.H WINDOW
NEW ANDERSEN D.H WINDOW
Machine-extracted for search and reference — the original PDF is the authoritative version.