2025-04-15 73 Melrose Civil Plans
site plan
5 pages
Meeting: portal event 1043 (no meeting page on file)
Agenda item: New Business — LNI Industries Inc., 73 Melrose Avenue (79.5-4-65) - Minor Site Plan Approval for New Single-Family Home
Site plan, 5 pages. Attached to agenda item: “New Business — LNI Industries Inc., 73 Melrose Avenue (79.5-4-65) - Minor Site Plan Approval for New Single-Family Home”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
Redacted Minor Site Plan Application 73 Melrose
Extracted text
S 45° 36' 17" E
67.11'
N 45° 36' 17" W
29.38'
N 27°15'20" E 130.81'
LANDS N/F OF
BARBARA KOVAROVIC,
AS TRUSTEE OF THE
BARBARA ZAJAC
IRREVOCABLE TRUST
CONTROL NO. 601883889
T.M. NO. 79.5-4-31
LANDS N/F OF
CROTON HARMON
SCHOOL DISTRICT
T.M. NO. 79.5-5-3
MELROSE AVENUE
10' WIDE STORM SEWER
EASEMENT AS PER
MAP REF. NO. 2
S 44°01'11" W 125.00'
PROPOSED 10' WIDE
SANITARY SEWER
EASEMENT
1 inch = 10 feet
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
APPLICABLE STATE AND / OR LOCAL LAWS
BY
DATE
REVISION
NO.
PROGRESS
PRINT
NOT FOR
CONSTRUCTION
PROPOSED SINGLE FAMILY HOME
73 MELROSE AVENUE
VILLAGE OF CROTON-ON-HUDSON
NEW YORK 10520
GREG MISITI
LNI HOMES, LLC
100 MORNINGSIDE DRIVE
CROTON-ON-HUDSON, NY 10520
SHEET NUMBER
PLOT DATE: April 3, 2025 3:25 PM
FILE NAME: N:\Projects\2024\124-277 LNI - 71 Melrose Ave 2 Lot Subdiv\Working\CADD\dwg\124-277_ecp.dwg
LAST SAVED BY:
Kamil A. Baraniewicz
DTF
03/31/25
FOR PLANNING BOARD SUBMISSION
CME No.:
124-277
DATE: MARCH 2025
SCALE:
of
DESIGNED BY: J. FINELLI
JOB MANAGER: S. FRANCIS
DESIGN SUPERVISOR:
D. ADAMS
DRAFTED BY: J. FINELLI
CHECKED BY: S. FRANCIS
DTF
04/03/25
REVISED PER ENGINEERING COMMENTS
KB
04/15/25
PER CLIENT COMMENTS
EXISTING CONDITIONS
& DEMO PLAN
C-1
S 45° 36' 17" E
67.11'
N 45° 36' 17" W
29.38'
N 27°15'20" E 130.81'
LANDS N/F OF
BARBARA KOVAROVIC,
AS TRUSTEE OF THE
BARBARA ZAJAC
IRREVOCABLE TRUST
CONTROL NO. 601883889
T.M. NO. 79.5-4-31
LANDS N/F OF
CROTON HARMON
SCHOOL DISTRICT
T.M. NO. 79.5-5-3
MELROSE AVENUE
10' WIDE STORM SEWER
EASEMENT AS PER
MAP REF. NO. 2
S 44°01'11" W 125.00'
PROPOSED 10' WIDE
SANITARY SEWER
EASEMENT
1 inch = 10 feet
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
APPLICABLE STATE AND / OR LOCAL LAWS
BY
DATE
REVISION
NO.
PROGRESS
PRINT
NOT FOR
CONSTRUCTION
PROPOSED SINGLE FAMILY HOME
73 MELROSE AVENUE
VILLAGE OF CROTON-ON-HUDSON
NEW YORK 10520
GREG MISITI
LNI HOMES, LLC
100 MORNINGSIDE DRIVE
CROTON-ON-HUDSON, NY 10520
SHEET NUMBER
PLOT DATE: April 3, 2025 3:25 PM
FILE NAME: N:\Projects\2024\124-277 LNI - 71 Melrose Ave 2 Lot Subdiv\Working\CADD\dwg\124-277_lmp.dwg
LAST SAVED BY:
Kamil A. Baraniewicz
DTF
03/31/25
FOR PLANNING BOARD SUBMISSION
CME No.:
124-277
DATE: MARCH 2025
SCALE:
of
DESIGNED BY: J. FINELLI
JOB MANAGER: S. FRANCIS
DESIGN SUPERVISOR:
D. ADAMS
DRAFTED BY: J. FINELLI
CHECKED BY: S. FRANCIS
DTF
04/03/25
REVISED PER ENGINEERING COMMENTS
KB
04/15/25
PER CLIENT COMMENTS
SITE & LANDSCAPING PLAN
C-2
SITE MAP (N.T.S.)
SITE
S 45° 36' 17" E
67.11'
N 45° 36' 17" W
29.38'
N 27°15'20" E 130.81'
S 44°23'43" W 125.00'
LANDS N/F OF
CROTON HARMON
SCHOOL DISTRICT
T.M. NO. 79.5-5-3
MELROSE AVENUE
10' WIDE STORM SEWER
EASEMENT AS PER
MAP REF. NO. 2
S 44°01'11" W 125.00'
PROPOSED 10' WIDE
SANITARY SEWER
EASEMENT
1 inch = 10 feet
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
APPLICABLE STATE AND / OR LOCAL LAWS
BY
DATE
REVISION
NO.
PROGRESS
PRINT
NOT FOR
CONSTRUCTION
PROPOSED SINGLE FAMILY HOME
73 MELROSE AVENUE
VILLAGE OF CROTON-ON-HUDSON
NEW YORK 10520
GREG MISITI
LNI HOMES, LLC
100 MORNINGSIDE DRIVE
CROTON-ON-HUDSON, NY 10520
SHEET NUMBER
PLOT DATE: ----
FILE NAME: N:\Projects\2024\124-277 LNI - 71 Melrose Ave 2 Lot Subdiv\Working\CADD\dwg\124-277_gdp.dwg
LAST SAVED BY:
Kamil A. Baraniewicz
DTF
03/31/25
FOR PLANNING BOARD SUBMISSION
CME No.:
124-277
DATE: MARCH 2025
SCALE:
of
DESIGNED BY: J. FINELLI
JOB MANAGER: S. FRANCIS
DESIGN SUPERVISOR:
D. ADAMS
DRAFTED BY: J. FINELLI
CHECKED BY: S. FRANCIS
DTF
04/03/25
REVISED PER ENGINEERING COMMENTS
KB
04/15/25
PER CLIENT COMMENTS
GRADING, DRAINAGE &
UTILITY PLAN
C-3
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
APPLICABLE STATE AND / OR LOCAL LAWS
BY
DATE
REVISION
NO.
PROGRESS
PRINT
NOT FOR
CONSTRUCTION
PROPOSED SINGLE FAMILY HOME
73 MELROSE AVENUE
VILLAGE OF CROTON-ON-HUDSON
NEW YORK 10520
GREG MISITI
LNI HOMES, LLC
100 MORNINGSIDE DRIVE
CROTON-ON-HUDSON, NY 10520
SHEET NUMBER
PLOT DATE: April 15, 2025 9:19 AM
FILE NAME: N:\Projects\2024\124-277 LNI - 71 Melrose Ave 2 Lot Subdiv\Working\CADD\dwg\124-277_msd.dwg
LAST SAVED BY:
Kamil A. Baraniewicz
DTF
03/31/25
FOR PLANNING BOARD SUBMISSION
CME No.:
124-277
DATE: MARCH 2025
SCALE:
of
DESIGNED BY: J. FINELLI
JOB MANAGER: S. FRANCIS
DESIGN SUPERVISOR:
D. ADAMS
DRAFTED BY: J. FINELLI
CHECKED BY: S. FRANCIS
DTF
04/03/25
REVISED PER ENGINEERING COMMENTS
KB
04/15/25
PER CLIENT COMMENTS
CONSTRUCTION DETAILS - 1
C-4
IN-LINE CLEANOUT DETAIL
SCALE: NTS
STABILIZED CONSTRUCTION ACCESS
SCALE: NTS
SOIL STOCKPILE STABILIZATION
SCALE: NTS
DECIDUOUS TREE PLANTING DETAIL
SCALE: NTS
TYPICAL SHRUB PLANTING DETAIL
SCALE: NTS
WATER SERVICE CONNECTION DETAIL
SCALE: NTS
SADDLE DETAIL
SCALE: NTS
UNREINFORCED RETAINING WALL
SCALE: NTS
TYPICAL SECTION - WALLS UP TO 4' HEIGHT
UNAUTHORIZED ALTERATION OR ADDITION
TO THIS DOCUMENT IS A VIOLATION OF
APPLICABLE STATE AND / OR LOCAL LAWS
BY
DATE
REVISION
NO.
PROGRESS
PRINT
NOT FOR
CONSTRUCTION
PROPOSED SINGLE FAMILY HOME
73 MELROSE AVENUE
VILLAGE OF CROTON-ON-HUDSON
NEW YORK 10520
GREG MISITI
LNI HOMES, LLC
100 MORNINGSIDE DRIVE
CROTON-ON-HUDSON, NY 10520
SHEET NUMBER
PLOT DATE: April 15, 2025 9:19 AM
FILE NAME: N:\Projects\2024\124-277 LNI - 71 Melrose Ave 2 Lot Subdiv\Working\CADD\dwg\124-277_msd.dwg
LAST SAVED BY:
Kamil A. Baraniewicz
DTF
03/31/25
FOR PLANNING BOARD SUBMISSION
CME No.:
124-277
DATE: MARCH 2025
SCALE:
of
DESIGNED BY: J. FINELLI
JOB MANAGER: S. FRANCIS
DESIGN SUPERVISOR:
D. ADAMS
DRAFTED BY: J. FINELLI
CHECKED BY: S. FRANCIS
DTF
04/03/25
REVISED PER ENGINEERING COMMENTS
KB
04/15/25
PER CLIENT COMMENTS
CONSTRUCTION DETAILS - 2
C-5
X
X
CONCRETE SIDEWALK DETAIL
SCALE: NTS
SILT FENCE DETAIL
SCALE: NTS
ASPHALT PAVEMENT SECTION
SCALE: NTS
PAVEMENT SAWCUT DETAIL
SCALE: NTS
PLEASE NOTE:
1.
THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED,
ANGULAR NO. 4 (AASHTO M43) STONE".
2.
STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
3.
WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION
EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS.
4.
ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C'
OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
NOTES:
1.
CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS"
CHAMBER CLASSIFICATION 45x76 DESIGNATION SS.
2.
MC-3500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
3.
THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION
FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
4.
PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
5.
REQUIREMENTS FOR HANDLING AND INSTALLATION:
·
TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.
·
TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3”.
·
TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 500 LBS/FT/%.
AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.
MATERIAL LOCATION
DESCRIPTION
AASHTO MATERIAL
CLASSIFICATIONS
COMPACTION / DENSITY REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE
TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE
PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT
PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.
N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE
TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm)
ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT
SUBBASE MAY BE A PART OF THE 'C' LAYER.
GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR
PROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS
LAYER.
AASHTO M145¹
A-1, A-2-4, A-3
OR
AASHTO M43¹
3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10
BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER
THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN
12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR
WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR
PROCESSED AGGREGATE MATERIALS.
B
EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS
FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER
ABOVE.
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M43¹
3, 4
A
FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE
SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER.
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M43¹
3, 4
PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3
8'
(2.4 m)
MAX
12" (300 mm) MIN
77" (1956 mm)
12" (300 mm) MIN
6"
(150 mm) MIN
6" (150 mm) MIN
PERIMETER STONE
(SEE NOTE 4)
EXCAVATION WALL
(CAN BE SLOPED OR VERTICAL)
MC-3500
END CAP
SUBGRADE SOILS
(SEE NOTE 3)
DEPTH OF STONE TO BE DETERMINED
BY SITE DESIGN ENGINEER 9" (230 mm) MIN
ADS GEOSYNTHETICS 601T NON-WOVEN
GEOTEXTILE ALL AROUND CLEAN, CRUSHED,
ANGULAR STONE IN A & B LAYERS
D
C
B
A
*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE
RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24" (600 mm).
45"
(1143 mm)
18" (450 mm)
MIN*
**THIS CROSS SECTION DETAIL REPRESENTS
MINIMUM REQUIREMENTS FOR INSTALLATION.
PLEASE SEE THE LAYOUT SHEET(S) FOR
PROJECT SPECIFIC REQUIREMENTS.
*FOR COVER DEPTHS GREATER THAN 8.0' (2.4 m) PLEASE CONTACT ADS
ADS STORMTECH MC-3500 UNDERGROUND INFILTRATION CHAMBER DETAIL
SCALE: NTS
Machine-extracted for search and reference — the original PDF is the authoritative version.