100 Young Ave Croton Plans PDF
map survey
9 pages
From the meeting:
Zoning Board of Appeals — 2026-04-21
· our coverage →
Agenda item: NEW PUBLIC HEARING — Matthew Dillon, owner---100 Young Ave---Located in a RA5 Residence District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.13 Block 1 Lot 13. Request for a side yard and front yard variance from Village Zoning Code Section 230-33(A) for a proposed 1st & 2nd story addition.
Map / plans, 9 pages. Attached to agenda item: “NEW PUBLIC HEARING — Matthew Dillon, owner---100 Young Ave---Located in a RA5 Residence District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 79.13 Block 1 Lot 13. Request for a side yard ”
Retrieved 2026-04-18 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
100 Young Ave ZBA Application 4.21.26 Redacted
100 Young Marked Property Survey
Extracted text
FINISHING NOTES:
1.
ALL WALLS AND CEILINGS TO BE 1
2" GYPSUM WALL BOARD TAPED AND SPACKLED 3
COATS MINIMUM. USE MOISTURE RESISTANT WALL BOARD ON AREA SUBJECT TO
MOISTURE.
2.
ALL CERAMIC TILE TO BE BACKED BY CEMENTITUOUS BACKER BOARD.
3.
ALL GLAZING TO BE SIZED, CONSTRUCTED, TREATED OR COMBINED WITH OTHER
MATERIALS TO MINIMIZE INJURIES IN THE EVENT OF BREAKAGE. (R308)
4.
ALL CLOSETS TO RECEIVE VINYL COVERING AND HANG RODS UNLESS
OTHERWISE NOTED.
5.
ALL BATHROOMS TO HAVE CERAMIC TILE FLOORS WITH A 4" CERAMIC TILE COVER
BASE. PROVIDE A MARBLE SADDLE AT DOORWAY THRESHOLD.
6.
ALL HANDRAILS TO CONFORM WITH CODE R311.7.8
BUILDING PLAN REVIEW NOTES:
TOWN BUILDING PLANS EXAMINER SHALL REVIEW THE
ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE PLANS
SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED IN
BUILDING AND OR RESIDENTIAL CODE OF THE STATE OF
NEW YORK. THIS REVIEW DOES NOT GUARANTEE
COMPLIANCE WITH THAT CODE. TO SEAL AND SIGNATURE
OF THE DESIGN PROFESSIONAL HAS BEEN INTERUPTED AS
AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S
BELIEF AND INFORMATION, THE WORK IN THE DOCUMENT
IS:
·
ACCURATE,
·
CONFORMS WITH GOVERNING CODES APPLICABLE AT
THE TIME OF SUBMISSION,
·
CONFORMS WITH REASONABLE STANDARDS OF
PRACTICE AND WITH VIEW TO THE SAFEGUARDING
OF LIFE, HEALTH AND PUBLIC WELFARE,
·
IS THE RESPONSIBILITY OF THE LICENSEE.
SYMBOLDESCRIPTION
WALL MOUNTED
LIGHT FIXTURE
CEILING MOUNTED
LIGHT FIXTURE
DUPLEX RECEPTACLE
OUTLET
SINGLE POLE
SWITCH
GFI
GROUND FAULT CIRCUIT
INTERRUPT RECEPTACLE
3-WAY SWITCH
(ROCKER ON/OFF)
NEW WALL
EXISTING WALLS REMOVED
PATCH & REPAIR
LINE OF FLOOR
ABOVE OR BELOW
SD/CO
SMOKE/CARBON
MONOXIDE
DETECTOR
GENERAL NOTES:
1.
IT IS THE INTENTION OF THESE DOCUMENTS TO PROVIDE FOR THE CONSTRUCTION
OF A RESIDENCE OR RESIDENTIAL ADDITION INCLUDING EVERY ITEM REQUIRED TO
COMPLETE THE WORK. ALL DISCREPANCIES TO BE REPORTED TO THE ARCHITECT.
2.
ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST RULES AND REGULATIONS OF
THE NEW YORK STATE BUILDING CODE AND ALL OTHER AGENCIES HAVING
JURISDICTION OVER THE WORK. IT SHALL NOT BE CONSTRUED TO MEAN THAT ANY
MORE STRINGENT REQUIREMENTS AS SET FORTH BY THESE DOCUMENTS MAY BE
MODIFIED.
3.
ALL MATERIALS AND CONSTRUCTION SHALL BE NEW IN STRICT COMPLIANCE WITH
THE LATEST STANDARDS OF THE VARIOUS TRADE ORGANIZATIONS ( ACI, AISC,
ETC...).
4.
ALL MATERIALS TO BE INSTALLED AS PER MANUFACTURERS SPECIFICATIONS.
5.
ALL WORK SHALL BE COORDINATED WITH ALL TRADES TO AVOID CONFLICTS.
6.
ALL CONTRACTORS TO MAINTAIN WORKMAN'S COMPENSATION AND DISABILITY
INSURANCE IN AMOUNTS REQUIRED BY LAW.
7.
ALL CONTRACTORS SHALL BE HELD TO HAVE VISITED THE JOB SITE TO BECOME
FAMILIAR WITH THE DIFFICULTIES OF A PROJECT.
8.
ALL CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, SOIL TEST REPORTS,
ETC. REQUIRED TO COMPLETE THE WORK.
9.
ALL CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS
EFFECTING THE WORK, INCLUDING DIMENSIONS TO INSURE PROPER STRENGTH, FIT
AND LOCATION OF THE WORK IF A CONDITION EXISTS WHICH DISAGREES WITH
THOSE SHOWN ON THE DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT. SHOULD THE CONTRACTOR FAIL TO FOLLOW THIS PROCEDURE HE
SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY ARISING THERE FROM.
10.
ALL CONTRACTORS SHALL VERIFY LOCATIONS OF EXISTING UNDERGROUND
UTILITIES.
11.
CONTRACTORS SHALL PROVIDE ALL NECESSARY SUPPORT, BRACING, SHORING,
ETC. TEMPORARY OR PERMANENT, AS REQUIRED TO SAFELY CONSTRUCT THE
PROJECT.
12.
ALL CONTRACTORS SHALL EXERCISE GOOD JUDGMENT TO MINIMIZE DAMAGE TO
EXISTING CONDITIONS ( INCLUDING LAWNS AND SHRUBS). ALL DAMAGED AREAS TO
BE RESTORED TO ORIGINAL CONDITIONS.
13.
THE CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE OWNER TO DESIGN,
PROVIDE AND INSTALL ALL MECHANICAL, ELECTRICAL AND PLUMBING WORK. ALL
SITE WORK, ALL MATERIALS AND ALL FINISHES WHICH ARE NOT OTHERWISE
INDICATED ON THE DOCUMENT AND/OR REQUIRED BY APPLICABLE CODES OR
OWNER REQUIREMENTS.
14.
ALL WORK SHALL BE FULLY GUARANTEED FOR ONE YEAR AFTER THE INSUANCE
DATE OF A CERTIFICATE OF OCCUPANCY.
15.
OWNER TO SELECT FINISH MATERIALS; KITCHEN AND BATHROOM FIXTURES. TYPE
AND LOCATION OF LIGHTING FIXTURES SWITCHED AND TELEPHONES JACKS.
16.
THE OWNER IS RESPONSIBLE OF OBTAINING THE FINAL SURVEY AND ALL COSTS
FOR BUILDING DEPARTMENT REQUIREMENTS.
17.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION MEANS,
METHODS, TECHNIQUE, SEQUENCES, PROCEDURES OR SAFETY PRECAUTIONS AND
PROGRAMS IN CONNECTION WITH THE WORK.
18.
THE ARCHITECT HAS NOT BEEN RETAINED FOR ANY FIELD SUPERVISION OR
INSPECTIONS.
19.
DUE NOT SCALE THESE DRAWINGS. UTILIZE DIMENSIONS ONLY. USE FIELD
DIMENSIONS IN COORDINATION WITH PLANNED DIMENSIONS.
SITE NOTES:
1.
PITCH GRADE AWAY FROM THE BUILDING (R401.3).
2.
STORM WATER TO BE DISPOSED OF IN ACCORDANCE WITH LOCAL CODE
REQUIREMENTS.
3.
ALL TREES WITHIN 15'-0" OF PROPOSED CONSTRUCTION TO BE PROTECTED.
4.
ALL LANDSCAPING DAMAGED BY THE CONSTRUCTION OPERATION TO BE REPLACED
AS REQUIRED.
5.
ALL DAMAGED CURBING, SIDEWALKS, ETC... TO BE REPLACED.
EXCAVATION NOTES:
1.
EXCAVATION CONTRACTOR TO EXCAVATE TRUE TO LINES AND GRADES DOWN TO
SPECIFIED LEVELS.
2.
ALL TOP SOIL TO BE STOCK PILED FOR FUTURE USE. ALL GOOD MATERIAL NEEDED
FOR BACK FILL TO BE STOCK PILED SEPARATELY. EXCESS AND UNACCEPTABLE
MATERIAL TO BE LEGALLY REMOVED FROM THE SITE.
3.
ALL BACK FILL TO BE PLACED IN 12" LIFTS AND COMPACTED LAYER BY LAYER TO 95
PERCENT PROCTER DENSITY AT OPTIMUM MOISTURE CONTENT AS DETERMINED BY
ASTM D 1557.
4.
BACKFILL AS PER CODE R404.1.7
CONCRETE NOTES:
1.
SOIL BARING CAPACITY IS ASSUMED TO BE 3000 PSF ( TABLE R401.4.1) SHOULD
POORER SOIL CONDITIONS BE ENCOUNTERED ACTUAL BEARING CAPACITY SHALL BE
DETERMINED AND FOOTINGS ARE TO BE REDESIGNED.
2.
ALL CONCRETE WORK TO CONFORM TO LATEST ACI CODE.
3.
ALL CONCRETE (TO INCLUDE GARAGE SLABS AND CONCRETE EXPOSED TO
WEATHERING) SHALL BE 3500 PSI AT 28 DAYS UNLESS OTHERWISE NOTED. ALL
EXPOSED CONCRETE SHALL BE AIR ENTRAINED ( TABLE R402.2).
4.
ADEQUATE PROTECTION TO BE MADE FOR CONCRETE AND MASONRY WORK
AGAINST FREEZING. NO CONCRETE OR MASONRY SHALL BE PERFORMED IN
5.
ADDITIVES SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE
ARCHITECT.
6.
ALL FOOTING TO BE CAST CONCRETE AND REST ON VIRGIN SOIL 3'-0" MINIMUM
BELOW GRADE, STEP AS REQUIRED ( R403.1.4).
7.
ALL FOOTING TO HAVE A PROJECTION AT EACH SIDE OF THE WALL ABOVE, PROVIDE
3 #5 CONTINUOUS REBARS UNLESS OTHERWISE NOTED (R403.1.3.5). - PROJECTION
NOT TO EXCEED THE FOOTING THICKNESS
8.
PROVIDE 2"x4" MINIMUM KEY WAY BETWEEN FOOTING AND FOUNDATION WALL
(R403.1.1).
9.
WALL FORMS TO REMAIN IN PLACE THREE DAYS MINIMUM.
10.
CONCRETE FOUNDATION WALLS SHALL BE CAST MONOLITHIC NO HORIZONTAL
JOINTS SHALL BE PERMITTED SHOULD A BREAK IN CASTING BE REQUIRED IT SHALL
BE VERTICAL AND THE SURFACE SHALL BE PREPARED PRIOR TO THE NEXT CAST.
11.
PROVIDE SLEEVES IN FOUNDATION WALLS AS REQUIRED FOR MECHANICAL,
ELECTRICAL, PLUMBING, TRADES AS REQUIRED COORDINATE WITH OTHER
CONTRACTORS, AGENCIES, ETC...
12.
CONCRETE CONTRACTOR SHALL PROVIDE ADEQUATE BRACING FOR ALL WALLS AS
REQUIRED TO EXIST WIND AND CONSTRUCTION LOADS.
13.
THE EXTERIOR SURFACE OF ALL FOUNDATION WALLS SHALL BE DAMPROOFED.
14.
ANCHOR BOLTS TO BE 5
8"Ø12" LONG WITH 3" HOOK AND 3"X3" WASHER SPACE 39"
O.C. MAXIMUM FOR 8'-0" END ZONES, AND 45" OC FOR INTERIOR ZONES. PROVIDE
TWO BOLTS AT EACH CORNER SPACED 1'-0" APART WITHIN 6" & 12" OF CORNER &
PLATE ENDS WITH MINIMUM OF 7" EMBEDMENT IN POURED CONCRETE & 15" IN
MASONRY BLOCK, FILL TOP TWO COURSES SOLID IN ACCORDANCE WITH WOOD
FRAME CONSTRUCTION MANUAL 3.2.1.7 TABLE 3.2A
15.
ALL SLABS ON GRADE SHALL REST ON A 6" COMPACTED BASE OF CLEAN SAND OR
GRAVEL INSTALL A 6 MIL. POLYETHYLENE VAPOR BARRIER PRIOR TO CASTING SLAB.
16.
ALL SLABS ON GRADE TO HAVE 6"x6" W1.4 x W1.4 WWM REINFORCING CONFORMING
TO ASTM A185. SEE R506 RESIDENTIAL CODE SECTION
17.
PROVIDE SAWED OR KEYED AND FORMED CONTROL JOINTS FOR SLAB AND WALKS
ON GRADE AT 20'-0" O.C. MAXIMUM IN BOTH DIRECTIONS.
18.
STEP FOOTINGS DOWN AS REQUIRED. MAXIMUM STEP FOOTINGS SHALL BE ONE
VERTICALLY TO TWO HORIZONTALLY WHERE ELEVATIONS CHANGE.
19.
CRAWL SPACE VENTS, IN ACCORDANCE WITH R408.1 ARE TO BE LOCATED WITHIN
3'-0" OF EACH CORNER OF THE BUILDING
20.
ACCESS TO CRAWL SPACE AS PER R408.4
ROUGH CARPENTRY NOTES:
1.
ALL LUMBER SHALL BE DOUGLAS FIR #1 OR BETTER, WITH AN EXTREME FIBER
STRESS (Fb) OF 850 PSI MINIMUM.
2.
ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE
TREATED UNLESS OTHERWISE NOTED. ( R317)
3.
THE ENTIRE WORK SHALL BE ACCURATELY FRAMED PLUMB, LEVEL AND TRUE
BRACED AND ANCHORED TOGETHER TO FORM A RIGID STRUCTURE; TO ENSURE
EVEN SETTLEMENT AND SHRINKAGE THROUGHOUT.
4.
ANCHOR BOLTS TO BE
8"Ø12" LONG WITH 3" HOOK AND 3"X3" WASHER SPACE 39"
O.C. MAXIMUM FOR 6'-0" END ZONES, AND 45" OC FOR INTERIOR ZONES. PROVIDE
TWO BOLTS AT EACH CORNER SPACED 1'-0" APART WITHIN 6" & 12" OF CORNER &
PLATE ENDS WITH MINIMUM OF 7" EMBEDMENT IN POURED CONCRETE & 15" IN
MASONRY BLOCK, FILL TOP TWO COURSES SOLID IN ACCORDANCE WITH WOOD
FRAME CONSTRUCTION MANUAL 3.2.1.7 TABLE 3.2, 3.2A, 3.2B, 3.3, & 3.3A
5.
ALL NAILS, BOLTS. JOIST HANGERS AND FRAMING CONNECTORS TO BE HOT DIPPED
GALVANIZED. ALL FLUSH CONNECTIONS TO BE SIMPSON STRONG TIE.
6.
ALL JOISTS, HEADERS, BEAMS AND RAFTERS TO HAVE 2" MINIMUM BEARING AT EACH
END.
7.
FLOOR JOISTS SHALL BE BRIDGED AT 8" O.C.
8.
ALL STRUCTURAL LUMBER SHALL BE KEPT 2" CLEAR OF CHIMNEYS AND FIRE BOXES.
9.
HEADERS, TRIMMERS AND JOISTS UNDER PARTITIONS TO BE DOUBLED. BLOCK
BETWEEN JOISTS UNDER PARTITIONS. STUD WALLS TO BE BLOCKED SOLID AT
MIDPOINT.
10.
PROVIDE HEADERS OVER ALL OPENINGS EQUAL TO FULL WIDTH OF FRAMING. ALL
WALL OPENINGS SHALL HAVE DOUBLE STUD JAMS. MINIMUM HEADER SIZE TO BE (2)
2"x6" FOR OPENINGS UP TO 3'-0" WIDE AND/OR (2) 2"x8" FOR OPENINGS UP TO 5'-0"
WIDE UNLESS OTHERWISE NOTED.
11.
ALL EXTERIOR WALL CORNERS TO HAVE FOUR STUDS MINIMUM NAILED WITH 16d @
12" O.C.
12.
ALL TOP PLATES TO BE DOUBLED WITH A 48" MINIMUM LAP SPLICE BUT JOINTS TO
OCCUR OVER A STUD NAIL WITH 16d @ 12" O.C. (WFCM TABLE 3.20)
13.
PROVIDE 3
4" CLEARANCE FROM TOP OF ALL INTERIOR NONBEARING PARTITIONS TO
UNDERSIDE OF FRAMING.
14.
ALL PLYWOOD USED STRUCTURALLY SHALL MEET THE PERFORMANCE STANDARDS
FOR TYPES AND SPECIES AS IDENTIFIED BY APPROVAL AGENCIES STAMP.
15.
ALL SHEATHING SHALL BE 1
2" DOUGLAS FIR EXTERIOR GRADE PLYWOOD NAILED AS
PER NAILING SCHEDULE PROVIDE TO INTERIOR INTERMEDIATE BLOCKING POINTS.
COVER SHEATHING WITH AIR INFILTRATION BARRIER PROPERLY TAPED AND
SEALED.
16.
PROVIDE COLLAR BEAMS AT ROOF RAFTERS AT 32" O.C.
17.
STRUCTURAL ENGINEERED LUMBER TO BE AS MANUFACTURED BY TRUSS JOIST
MACMILLAN OR APPROVED EQUAL.
18.
PROVIDE FIRE BLOCKING AS PER R602.8 & 502.13 IN ACCORDANCE WITH SECTION
R302.11 (FIREBLOCKING), DRAFT STOPPING AS PER 502.12 IN ACCORDANCE R302.12
(DRAFTSTOPPING)
19.
WINDOW INSTALLATION AS PER R609.5 AND R609.6.
20.
ALL WOOD SILLS, BLOCKING, NAILERS, ETC...IN CONTACT WITH MASONRY,
CONCRETE OR SOIL TO BE ACQ (TREATED).
21.
ALL SUB-FLOORS TO BE 3
4" PLYWOOD NAILED WITH 8d MINIMUM AS PER NAILING
SCHEDULE.
22.
FOR HEADERS OVER 5'-0" LONG USE DOUBLE JACK STUDS.
23.
MANUFACTURED BY TJI CORP. OR APPROVED EQUAL.
24.
MATERIAL FOR STRUCTURAL MEMBERS IS TO BE IDENTIFIED IN ACCORDANCE WITH
R502.1.1 MATERIAL FOR LOAD BEARING STUDS, PLATES AND HEADERS ARE TO
IDENTIFIED IN ACCORDANCE WITH R602.1.1
25.
STRUCTURAL FLOOR MEMBERS ARE NOT TO BE CUT, BORED, OR NOTCHED IN
ACCESS OF THE LIMITATIONS SPECIFIED IN FIGURE R502.8. CUTS, NOTCHES AND
HOLES BORED IN ENGINEERED WOOD PRODUCTS ARE NOT PERMITTED UNLESS THE
EFFECTS OF SUCH PENETRATION ARE SPECIFICALLY CONSIDERED IN THE DESIGN
OF THE MEMBER, IN ACCORDANCE WITH R502.8.2. STUD DRILLING AND NOTCHING
ARE ALSO TO COMPLY WITH R602.6. ( SEE DETAIL)
26.
IN ACCORDANCE WITH SECTION R312.1, REQUIRED GUARDS FOR HANDRAILS ARE TO
27.
ALL CLOSET SHELVES TO BE CLEAR PINE UNLESS OTHERWISE NOTED.
28.
PROVIDE 1
4"
29.
STAIR TREAD SHALL BE 11
4" THICK CLEAR OAK, UNLESS OTHERWISE NOTED.
30.
CERAMIC TILE SURFACES AND INSTALLATION ARE TO COMPLY WITH R702.4, OTHER
FINISHES TO COMPLY WITH R702.5 AND R702.6.
31.
ANY CHANGES TO THE STRUCTURE SHOULD BE BROUGHT TO THE ATTENTION OF
THE ARCHITECT BEFORE CHANGES ARE MADE TO THE STRUCTURE ON SITE.
FINISH CARPENTRY NOTES:
1.
HARD WOOD FLOORS TO BE 1"x 2" TONGUE & GROOVE OAK (B GRADE) INSTALLED
OVER ROSEN PAPER. SANDED SMOOTH AND FINISH WITH 2 COATS OF
POLYURETHANE.
2.
STAIR TRENDS TO BE 11
4" THICK CLEAR OAK UNLESS OTHERWISE NOTED.
3.
INTERIOR TRIM SHALL BE CLEAR MATERIAL UNLESS OTHERWISE NOTED. EXTERIOR
TRIM TO BE CLEAR MATERIAL TO MATCH SIDING.
4.
ALL EXTERIOR DOORS TO BE FULLY WEATHER STRIP.
5.
ALL INTERIOR DOORS TO BE 13
4" THICK RAISED PANEL UNLESS OTHERWISE NOTED.
ALL JAMBS AND BUCKS TO BE CLEAR.
CONNECTION DETAILS:
1.
ALL FRAMING HARDWARE TO BE SIMPSON STRONG TIE OR APPROVED EQUAL.
2.
DUE TO THE NATURE OF FRAMING HARDWARE TO THE OTHER COMPONENTS OF THE
STRUCTURE, SUBSTITUTION WILL RESULT IN THE CONTRACTOR ASSUMING
RESPONSIBILITY FOR THE DESIGN AND PERFORMANCE OF THE ENTIRE SYSTEM.
3.
ALL SPECIFIED FASTENERS TO BE INSTALLED AS PER MANUFACTURE
SPECIFICATIONS. INCORRECT FASTENER QUANTITY, SIZE, TYPE, MATERIAL OR
FINISH MAY CAUSE THE CONNECTION TO FAIL. 16d COMMON NAILS CAN NOT BE
REPLACED BY 16d SINKERS UNLESS OTHERWISE NOTED.
4.
INSTALL ALL FASTENERS BEFORE LOADING THE CONNECTION.
5.
JOIST SHALL BEAR COMPLETELY ON THE CONNECTOR SEAT AND ANY GAP BETWEEN
THE JOIST AND THE HEADER SHALL NOT EXCEED 1
4" AS PER ASTM TEST STANDARDS.
6.
ANCHOR BOLT NUTS SHOULD BE FINGER TIGHTENED PLUS ONE TURN WITH A
WRENCH. CONSIDERATION FOR FUTURE WOOD SHRINKAGE SHALL BE GIVEN. CARE
SHALL BE TAKEN TO AVOID OVER TORQUING THE NUT.
7.
CONNECTIONS @ WOOD FRAME ARE IN ACCORDANCE WITH SECTION 3.2 OF 2020
WOOD FRAME CONSTRUCTION MANUAL HIGH WIND MANUAL AS PER R301.2.1.1
STEEL NOTES:
1.
ALL STRUCTURAL STEEL SHALL CONFORM TO LATEST ASTM SPECIFICATIONS FOR
A-36 STEEL.
2.
ALL STEEL WORK TO CONFORM LATEST AISC SPECIFICATIONS.
3.
ALL REINFORCING BARS TO BE DEFORMED INTERMEDIATE GRADE NEW BILLET
STEEL CONFORMING TO ASTM A615 GRADE 60 HAVING DESIGN STRENGTH OF 60,000
PSI.
4.
ALL REINFORCING BARS TO BE CONTINUOS UNLESS SPECIFIC LENGTHS ARE
SHOWN. ALL SPLICES TO BE ( 40) BAR DIAMETERS MINIMUM.
5.
WELDED WIRE FABRIC TO BE 6" x 6" W1.4 x W1.4 WHICH SHALL CONSIST COLD
DRAWN MEMBERS HAVING AND ULTIMATE STRENGTH NOT LESS THAN 70,000 PSI.
6.
ALL REINFORCING TO BE SECURELY FASTENED TO RESIST MOVEMENT DURING
CONCRETE PLACEMENT.
7.
WELDED WIRE FABRIC OR EQUIVALENT STEEL AREA MAY SUBSTITUTED FOR ANY
REINFORCING BAR GRID.
MEP COMPLIANCE STATEMENT:
THE EXISTING HEATING, ELECTRICAL AND PLUMBING SYSTEMS ARE CAPABLE OF HANDLING
THE IMPOSED LOADS OF THE PROPOSED ALTERATION.
IF IT IS DETERMINED THAT ANY OF THESE EXISTING SYSTEMS ARE NOT CAPABLE, THEN IT WILL
BE UPGRADED TO MEET COMPLIANCE
MECHANICAL NOTES:
1.
A 15 MPH WIND VELOCITY.
2.
ALL KITCHEN AND BATHROOM VENTS TO COMPLY WITH STATE CODES.
3.
ALL FIRE BOXES SHALL BE LINED WITH FIRE BRICK AS PER ASTM C106 PROVIDE
EXTERIOR COMBUSTION AIR AS PER ENERGY CODE.
4.
FLUE LINING TO BE TERRA COTTA FOR FULL HEIGHT EXTENDING TRUE CHIMNEY CAP.
ALTERNATE: PREFABRICATED INSULATED METAL CHIMNEY INSTALLED AS PER
MANUFACTURER SPECIFICATIONS.
5.
ALL MECHANICAL WORK TO CONFORM TO NYS RESIDENTIAL CODE CHAPTERS 12
THROUGH 23.
INSULATION NOTES:
1.
INSULATION IN EXTERIOR WALLS AND CEILING OF ALL HEATED SPACES TO BE
FIBERGLASS BATS WITH A CONTINUOUS VAPOR BARRIER FACING THE HEATED SPACE.
PACK ALL SPACES AROUND THE OPENINGS.(R302.10.1)
2.
INSULATION IN VAULTED CEILINGS TO BE INSTALLED AS TO MAINTAIN THE FREE
PASSAGE OF AIR BETWEEN THE EXTERIOR FACE OF INSULATION AND THE INTERIOR
FACE OF THE ROOF SHEATHING.
3.
ACOUSTICIAL INSULATION TO BE PROVIDED IN WALLS, FLOORS AND CEILINGS AROUND
ALL BATHROOMS, BEDROOMS AND MECHANICAL ROOMS.
4.
PROVIDE PERIMETER INSULATION AS PER CODE AT ALL FOUNDATION WALLS
5.
ALL FLASHING AS PER R703.4 AND R903.
6.
ALL ROOF ASSEMBLIES TO COMPLY WITH R902, R903 AND R904.
7.
ROOFING NAILS AS PER R905.2.5 AND ASTM F1667 12 GAUGE SHANK WITH 3
8"
FASTENERS PER SHINGLE
8.
R VALUES ARE DISPLAYED IN SECTIONS (SEE PLAN FOR SPECIFIC VALUES)
9.
MOISTURE VAPOR RETARDERS ARE TO BE INSTALLED ON THE WARM - IN WINTER SIDE
OF INSULATION IN ALL WALLS, FLOORS, ROOFS AND CEILING IN ACCORDANCE WITH
SECTION R702.7.
10.
INSULATION MATERIAL IS TO COMPLY WITH SECTION R302.10.1 AND IS TO HAVE A
FLAME SPREAD INDEX NOT TO EXCEED 25 WITH A SMOKE DEVELOPED INDEX NOT TO
EXCEED 450. TESTING METHODS MUST COMPLY WITH ASTM E84 STANDARD. NALL
EXPOSED INSULATION ON ATTIC FLOORS ARE TO HAVE MINIMUM CRITICAL RADIANT
FLUX OF .12 WATTS PER CENTIMETER SQUARED. TESTING TO BE CARRYED OUT AS
PER ASTM E970 STANDARD. EXTERIOR INSULATED FINISH SYSTEM TO COMPLY WITH
R703.9.
PLUMBING NOTES:
1.
ALL PIPING, JOINTS, SUPPORTS AND CLEAN OUTS TO CONFORM TO LOCAL CODE
REQUIREMENTS.
2.
ALL PLUMBING FIXTURES TO BE VENTED AND TRAPPED.
3.
PROVIDE SHUT OFF VALVES ON ALL SUPPLY LINES AT ALL FIXTURES.
4.
INSULATE ALL SUPPLY LINES.
5.
PROVIDE TWO FROST FREE HOSE BIBS MINIMUM.
6.
ALL FIXTURES TO BE KOHLER, AMERICAN STANDARD, OR APPROVED EQUAL.
FURNISHED AND INSTALLED BY CONTRACTOR.
7.
PLUMBING CONTRACTOR TO SUPPLY AND INSTALL 40 GALLON PER HOUR HOT WATER
HEATER.
8.
ALL PLUMBING WORK TO CONFORM TO NYS RESIDENTIAL CODE CHAPTERS 25
THROUGH 32.
ELECTRICAL NOTES:
1.
ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRIC
CODE, LOCAL MUNICIPALITIES, NFPA 70-2020 AND STATE AUTHORITIES HAVING
JURISDICTION. CONTRACTORS SHALL PAY FOR AND OBTAIN AN UNDERWRITERS
CERTIFICATE.
2.
CONTRACTOR TO VERIFY ADEQUACY OF EXISTING SERVICE AT EXISTING PANEL BASE
BID ON 200 AMP SERVICE FOR NEW WORK.
3.
ALL WIRING TO BE COLOR CODED 14 AWG COPPER.
4.
CONVENIENT OUTLETS TO BE 18" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.
5.
PROVIDE GROUND FAULT CIRCUIT INTERRUPTER OUTLETS AS PER CODE.
6.
ELECTRICAL CONTRACTOR TO PROVIDE HOOK UPS FOR HEATING AND AIR
CONDITIONING SYSTEMS.
7.
ELECTRICAL CONTRACTOR TO COORDINATE WITH OTHER TRADES.
8.
ALL OUTLETS, SWITCHED, ETC... TO BE AS MANUFACTURED BY LUTRON DESIGNER
SERIES SKYLARK DECORA OR APPROVED EQUAL.
9.
PROVIDE 2 EXTERIOR WATER PROOF OUTLETS ON NEW WORK.
10.
PROVIDE SINGLE STATION ALARM DETECTION DEVICE INSTALLED IN CONFORMANCE
WITH SECTION R314 AND AJ102.3 ON OR NEAR THE CEILING ADJACENT TO ALL
SLEEPING SPACES ON EACH FLOOR LEVEL. UNIT TO DETECT FIRE, SMOKE AND
CARBON MONOXIDE. ALL DETECTORS TO BE INTERCONNECTED.
11.
ALL ELECTRICAL WORK TO CONFORM TO NYS RESIDENTIAL CODE CHAPTERS 33
THROUGH 42.
WINDOW AND DOOR NOTES:
1.
ALL WINDOWS AND SLIDING GLASS DOORS TO BE VINYL CLAD WOOD WITH INSULATED
GLASS, SCREENS AND LOCKS AS MANUFACTURED BY ANDERSON OR APPROVED
EQUAL SIZES AND TYPES AS INDICATED ON PLANS UNLESS OTHERWISE NOTED.
2.
ALL EXTERIOR DOORS TO BE INSULATED METAL AS MANUFACTURED BY BENCHMARK,
STANLEY, OR APPROVED EQUAL. SIZES AND TYPES AS INDICATED ON PLANS. FULLY
WEATHER STRIPPED, LOCKS. UNLESS OTHERWISE NOTED.
3.
ALL INTERIOR DOORS TO BE 13
4" THICK, HOLLOW CORE, FLUSH BIRCH, U.O.N. ALL DOOR
JAMBS AND BUCKS TO BE CLEAR PINE.
EGRESS WINDOW NOTES:
- R310.2.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL
HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE NET CLEAR HEIGHT
OPENING SHALL NOT BE LESS THAN 24 INCHES AND NET CLEAR WIDTH SHALL NOT BE
LESS THAN 20 INCHES.
EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5
SQUARE FEET.
-R310.1.1 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESUE OPENINGS SHALL
BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR
TOOLS.
-R310.2.2 WHERE EMERGENCY ESCAPE AND RESUE OPENINGS ARE PROVIDED THEY SHALL
HAVE A SILL HEIGHT OF NO MORE THAN 44 INCHES ABOVE THE FLOOR.
ALL WINDOWS TO BE SUPPLIED BY THE FOLLOWING MANUFACTURES AS NOTED ON PLAN.
ANDERSON WINDOWS, INC
100 FOURTH AVENUE NORTH
BAYPORT, MN 55003-1096
CONFORMS TO AAMA/NWWDA 101/I.S. 2-97
CAPITOL WINDOWS AND DOORS
MI HOME PRODUCTS, INC
650 W. MARKET STREET
P.O. BOX 370
GRATZ, PA 17030-0370
CONFORMS TO AAMA/NWWDA 101/I.S. 2-97
ALL WINDOWS IN PLANS TO HAVE A RO. OF 6' - 101
2" TO BOTTOM OF HEADER UNLES OTHERWISE
NOTED
NYS RESIDENTIAL CODE NOTES:
-
ALL CONSTRUCTION HAS BEEN DESIGNED IN ACCORDANCE WITH THE
EXTANT ADDITION OF THE AMERICAN FOREST AND PAPER ASSOCIATION
(AF&PA) WOOD FRAME CONSTRUCTION MANUAL (WFCM) 2020 FOR ONE
AND TWO FAMILY DWELLINGS, HIGH WIND ADDITION.
-
DESIGN CRITERIA-CLIMATIC AND GEOGRAPHIC ( R301)
- GROUND SNOW LOAD..........................................20 PSF
- WIND SPEED........................................................130 MPH
- WIND ZONE........................................................................1
- WIND EXPOSURE CATEGORY............................................B
- SEISMIC DESIGN CATEGORY ...........................................B
- WEATHERING ..........................................................SEVERE
- FROST LINE DEPTH .................................................3'-0"
- TERMITE .............................................MODERATE/HEAVY
- DECAY ...............................................SLIGHT/MODERATE
- ICE SHIELD UNDERLAYMENT...............................REQUIRED
- FLOOD HAZARD....................AS PER FEMA & NFIP MAPS
- SITE CLASSIFICATIONS.....................................................D
-
DESIGN CRITERIA - DESIGN LOADS ARE IN COMPLIANCE WITH SECTIONS
R301.4 & R301.5, R301.6
-ROOF LOADS: ALLOWABLE DEFLECTIONS COMPLY WITH SECTION
R301.6
-SNOW LOAD...............................................20 PSF - TABLE R301.2(5)
RESIDENTIAL CODE OF N.Y.S. (PAGE 49)
-DEAD LOAD...................................................15 PSF
-ATTIC LOADS:
- STORAGE ATTIC..........................................20 PSF
- NON STORAGE ATTIC..................................10 PSF
TABLE 4-1 ASCE (PAGE 13)
-FLOOR LOADS:
TABLE 4-1 ASCE (PAGE 13)
- LIVE LOAD..................................................40 PSF
- DEAD LOAD................................................10 PSF
TABLE 4-1 ASCE (PAGE 13)
-WALL LOADS:
- DEAD LOAD................................................15 PSF
-WIND LOADS:
- FROM FIGURE 6-1c ASCE (PAGE 40)
- FROM FIGURE R301.2(4) RESIDENTIAL CODE OF N.Y.S. (PAGE 30)
-UPLIFT:.............................................................WIND EXPOSURE "B"
CATEGORY
- FROM AF & PA WOOD FRAME CONSTRUCTION MANUAL
-SEISMIC LOAD:
- FROM FIGURE R301.2(2) RESIDENTIAL CODE OF N.Y.S. (PAGE 28)
-
ALLOWABLE DEFLECTIONS ( TABLE R301.7)
- RAFTERS WITH SLOPES GREATER THAN 3
12...L/180
NO FINISHED CEILINGS
- INTERIOR WALLS AND PARTITIONS.................H/180
- FLOORS AND PLASTERED CEILINGS................L/160
- ALL OTHER STRUCTURAL MEMBERS..............L/240
-EXTERIOR WALLS WITH PLASTER OR STUCCO
FINISH.........................................................................H/360
- EXTERIOR WALL- BRITTLE FINISHES...............L/240
- EXTERIOR WALL- FLEXIBLE FINISHES............L/120
-
WINDOW OPENING PROTECTION
- REMOVABLE SHUTTERS ( R301.2.1.2)
-
16"PLYWOOD PRE-CUT TO COVER GLAZED
OPENINGS WITH ATTACHEMENT HARDWARE
(2 1
2"# 8 WOOD SCREWS @ 16' Oc
- EACH SHUTTER TO BE LABELED FOR THE
SPECIFIC WINDOW IT IS TO PROTECT
-
DESIGN CRITERIA- UPLIFT - WOOD FRAME CONSTRUCTION MANUAL 3.2.2
- 11
4"x 20" GUAGE STRAP
- ROOF TO WALL CONNECTION- WFCM SECTION 3.2.2.1
- WALL TO WALL CONNECTION- WFCM SECTION 3.2.2.2
- WALL TO FOUNDATION CONNECTION- WFCM SECTION 3..2.2.3
- RAFTER TO RAFTER OVER RIDGE- WFCM SECTION 3.2.6
- SECTION 3.2.1.7 - WALL ASSEMBLY OR SILL PLATE TO FOUNDATION
SILL PLATES OR WALL BOTTOM PLATES SHALL BE ANCHORED TO THE
FOUNDATION SYSTEM TO RESIST LATERAL & SHEER LOADS FROM WIND
IN ACCORDANCE w/THE REQUIREMENTS OF TABLE 3.2. PRESCRIPTIVE
SOLUTIONS PROVIDED FOR SILL PLATE TO FOUNDATION IN TABLE 3.2A, &
FOR BOTTOM PLATE TO FOUNDATION TABLE 3.2B. SILL PLATES OR WALL
BOTTOM PLATES TO BE ANCHORED TO THE FOUNDATION TO SYSTEM TO
RESIST SEISMIC SHEAR LOADS IN ACCORDANCE w/TABLE 3.3. SOLUTIONS
FOR SILL OR BOTTOM PLATE TO FOUNDATION TABLE 3.3A. A MIN. OF 1
ANCHOR BOLT SHALL BE PROVIDED WITHIN 6 TO 12 INCHES OF EACH
END OF EACH PLATE. ANCHOR BOLTS TO BE EMBEDDED A MIN. OF 7
INCHES IN CONC. FOUNDATIONS & SLABS ON GRADE, OR IN MASONRY
BLOCK FOUNDATIONS WHEN RESISTING LATERAL & SHEER LOADS
(FIGURE 3.2A-C) ANCHOR BOLTS LOCATED WITHIN 12 INCHES OF
CORNERS, AS SPECIFIED BY TABLE 3.2A-B OR TABLE 3.3A, NOT TO
EXCEED 6 FEET O.C. SILL PLATES & BOTTOM PLATE TO FULLY BEAR ON
FOUNDATION SYSTEM.
- SECTION 3.2.2.1 - ROOF ASSEMBLY TO WALL ASSEMBLY
RAFTER OR TRUSS TO WALL STUD UPLIFT CONNECTIONS SHALL BE IN
ACCORDANCE WITH THE REQUIREMENTS OF SECTION 3.2.2.1.
PERSPECTIVE SOLUTIONS USING UPLIFT STRAPS ARE PROVIDED IN
TABLE A-3.4. WHERE RAFTERS OR TRUSSES ARE NOT ATTACHED
DIRECTLY TO STUDS, RAFTERS OR TRUSSES SHALL BE ATTACHED TO
THE WALL TOP PLATE, WITH THE WALL TOP PLATE ATTACHED TO THE
WALL STUD w/UPLIFT CONNECTIONS IN ACCORDANCE w/TABLE 3.4. ROOF
TO TOP PLATE CONNECTIONS SHALL BE ON THE SAME SIDE OF THE
WALL AS TOP PLATE TO STUD CONNECTIONS UNLESS OTHER METHODS
ARE USED TO PREVENT TWISTING OF THE TOP PLATE DUE TO
ECCENTRIC LOADING (FIGURE 3.2J-K). WOOD STRUCTURAL PANELS
SHALL BE PERMITTED TO RESIST WALL TOP PLATE TO WALL STUD
UPLIFT WHEN DESIGNED IN ACCORDANCE WITH 3.2.3 PRESCRIPTIVE
SOULTIONS TO RESIST WIND UPLIFT ARE PROVIDED IN TABLE 3.4B.
- SECTION 3.2.2.2 - WALL ASSEMBLY TO WALL ASSEMBLY
STORY TO STORY UPLIFT CONNECTIONS FROM UPPER STORY WALL
STUD TO LOWER STORY WALL STUD SHALL BE IN ACCORDANCE w/THE
REQUIREMENTS OF TABLE 3.4. PRESCRIPTIVE SOLUTIONS USING UPLIFT
STRAPS ARE PROVIDED IN TABLE A-3.4. WHERE UPPER STORY WALL
STUDS ARE NOT ATTACHED DIRECTLY TO LOWER STORY WALL STUDS,
THE STUDS SHALL BE ATTACHED TO A COMMON MEMBER IN THE FLOOR
ASSEMBLY w/ UPLIFT CONNECTIONS IN ACCORDANCE w/TABLE 3.4.
WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO RESIST WALL
PLATE TO WALL STUD UPLIFT WHEN DESIGNED IN ACCORDANCE w/3.2.3.
PRESCRIPTIVE SOLUTIONS TO RESIST WIND UPLIFT ARE PROVIDED IN
TABLE 3.4B.
- SECTION 3.2.2.3 - WALL ASSEMBLY TO FOUNDATION - FIRST FLOOR WALL
STUDS SHALL BE CONNECTED TO THE FOUNDATION, SILL PLATE, OR
BOTTOM PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF TABLE
3.2. PRESCRIPTIVE SOLUTIONS ARE PROVIDED IN TABLE A-3.4 (SEE
FIGURES 3.2A-E).
STEEL CONNECTORS USED TO RESIST UPLIFT SHALL BE A MIN. OF A
4"x20 GAGE ASTM A653 GRADE 33 STEEL STRAP & HAVE A MIN.
EMBEDMENT OF 7" IN CONC. FOUNDATIONS AND SLABS ON GRADE, 15" IN
MASONRY BLOCK FOUNDATIONS, OR BE LAPPED UNDER THE PLATE AND
NAILED IN ACCORDANCE w/STEEL CONNECTOR REQUIREMENTS (SEE
FIGURES 3.2A-C). WHERE THE STEEL STRAP IS LAPPED UNDER THE
BOTTOM PLATE, 3" SQUARE WASHERS SHALL BE USED ON THE ANCHOR
BOLTS & ANCHOR BOLT SPACINGS SHALL NOT EXCEED THE
REQUIREMENTS SPECIFIED IN TABLE 3.2C. IF STEEL CONNECTORS THAT
ONLY FASTEN TO ONE SIDE OF THE BOTTOM PLATE ARE USED, THE
SQUARE WASHER SHALL EXTEND TO WITHIN 1
2" OF THE EDGE OF THE
PLATE TO WHICH THE CONNECTOR IS NAILED. STEEL STRAPS EMBEDDED
IN OR IN CONTACT w/ SLAB ON GRADE OR MASONRY BLOCK
FOUNDATIONS SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION,
OR MANUFACTURED FROM G185 OR Z450 GALVANIZED STEEL.
WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO RESIST WALL
STUD TO FOUNDATION, SILL PLATE, OR BOTTOM PLATE UPLIFT WHEN
DESIGNED IN ACCORDANCE w/3.2.3. PRESCRIPTIVE SOLUTIONS TO
RESIST WIND UPLIFT ARE PROVIDED IN TABLE 3.4B. WHERE WOOD
STRUCTURAL PANELS ARE USED TO RESIST UPLIFT, BOTTOM PLATES OR
SILL PLATES SHALL BE ANCHORED IN ACCORDANCE w/3.2.3.6
NAILING SCHEDULE (WFCM 2020)- COMMON NAILS:
WFCM TABLE 3.1, 3.3A, 3.4A,,3.5A,3.6A 3.8 & 3.9A
- ROOF FRAMING
- RAFTER TO TOP PLATE ( TOE NAILED)...................3-8d PER RAFTER
- CEILING JOIST TO TOP PLATE
(TOE NAILED)...........................................................3-8d PER JOIST
- CEILING JOISTS TO PARALLEL RAFTER
(FACE NAILED)........................................................7-16d EACH LAP
- CEILING JOISTS LAPS OVER PARTITIONS
(FACE NAILED)........................................................7-16d
EACH LAP
- COLLAR TIE TO RAFTER (FACE NAILED).................2-8d
PER TIE
- BLOCKING TO RAFTER (TOE NAILED).....................2-8d EACH END
- RIM BOARD TO RAFTER (END NAILED)..................2-16d EACH END
- WALL FRAMING
- TOP PLATE TO TOP PLATE (FACE NAILED)...........2-16d PER FOOT
- TOP PLATES AT INTERSECTIONS
FACE NAILED............................................................4-16d PER JOINTS
- STUD TO STUD (FACE NAILED)...............................2-16d
24"O.C.
- HEADER TO HEADER (FACE NAILED)..........................16d 16"O.C. @ EDGES
- TOP OR BOTTOM PLATE TO STUD
(END NAILED)..........................................................2-16d PER STUD
-BOTTOM PLATE TO FLOOR JOISTS, BAND JOIST,
END JOIST OR BLOCKING (FACE NAILED)............2-16d PER FOOT
- FLOOR FRAMING
- JOISTS TO SILL, TOP PLATE OR GIRDER
(TOE NAILED)............................................................4-8d PER JOIST
- BRIDGING TO JOIST (TOE NAILED)........................2-8d EACH END
- BLOCKING TO JOIST ( TOE NAILED)......................2-8d EACH END
- BLOCKING TO SILL OR TOP PLATE
(TOE NAILED)...........................................................3-16d EACH BLOCK
- LEDGER STRIP TO BEAM (FACE NAILED)..............3-16d EACH JOIST
- JOIST ON LEDGER TO BEAM
(TOE NAILED)...........................................................3-8d PER JOIST
- BAND JOIST TO JOIST (END NAILED)...................3-16d PER JOIST
- BAND JOIST TO SILL OR TOP PLATE
(TOE NAILED)..........................................................2-16d PER FOOT
- ROOF SHEATHING
- STRUCTURAL PANELS 4" GABLE OVERHANG
TYPICAL WALL.....................................................8d 6" EDGE
12" FIELD
- STRUCTURAL PANELS
FOR 4'-0" AROUND WALL PERIMETER............8d 6" EDGE
12" FIELD
- DIAGONAL BOARD SHEATHING
1" x 6" OR 1" x 8"........................................2-8d PER SUPPORT
1" x 10" OR WIDER.........................................3-8d PER SUPPORT
- CEILING SHEATHING
-GYPSUM WALL BOARD.................................5d COOLERS 7" EDGE
10" FIELD
- WALL SHEATHING
- STRUCTURAL PANELS
TYPICAL WALLS...................................................8d 6" EDGE
12" FIELD
- STRUCTURAL PANELS
FOR 4'-0" AROUND WALL PERIMETER............8d
6" EDGE
12" FIELD
- FIBERBOARD PANELS
PANELS.......................11 GALVANIZED ROOFING 3" EDGE
(0.120"x1 1
2"LONG x7 1
16" HEAD) 6" FIELD
PANELS.....................11 GALVANIZED ROOFING 3" EDGE
(0.120"x13
4" LONG x 3
8" HEAD) 6" FIELD
- GYPSUM WALL BOARD...................................5d COOLER
7" EDGE
10" FIELD
- HARDOARD......................................................................8d 6" EDGE
12" EDGE
- PARTICLE BOARDS.........................................................8d SEE MANUFACTURE
- DIAGONAL BOARD SHEATHING
1" x 6" OR 1" x 8"........................................2-8d PER SUPPORT
1" x 10" OR WIDER.........................................3-8d PER SUPPORT
- FLOOR SHEATHING
STRUCTURAL PANELS 1" OR LESS......................8d 6" EDGE
12" FIELD
GREATER THAN 1"..............................................10d 6" EDGE
12"FIELD
- DIAGONAL BOARD SHEATHING
1"x6" OR 1"x8".............................................2-8d PER SUPPORT
1"x10" OR WIDER...........................................3-8d PER SUPPORT
ROOFING/SIDING NOTES:
1.
ROOF COVERING MATERIALS ARE TO COMPLY WITH SECTIONS R902, R904 AND
R905 AND ARE TO IDENTIFIED IN ACCORDANCE WITH R904.4. ROOF DRAINS ARE TO
BE INSTALLED IN ACCORDANCE WITH R 903.4. DRAWINGS AND DETAILS ARE TO BE
SUBMITTED.
2.
UNDERLAYMENT FOR ASPHALT SHINGLES, CLAY & CONCRETE TILE, METAL
ROOFING SHINGLES, SLATE & SLATE TYPE SHINGLES, WOOD SHINGLES, WOOD
SHAKES & METAL ROOFING PANELS TO COMPLY WITH SECTION R905.1.1. SELF
STEEL STRIPS AND FASTENERS ARE TO COMPLY WITH R905.2 AND R905.2.5
DETAILS OF ASPHALT SHINGLE ROOFING INSTALLATIONS ARE TO BE SUBMITTED.
FOR ROOF SLOPES OF 4
12, DOUBLE UNDERLAYMENT IS REQUIRED IN ACCORDANCE
WITH TABLE R905.1.1(2). THE REQUIRED UNDERLAYMENT IS TO CONFORM WITH
ASTM D226, TYPE ONE OR ASTM D4869, TYPE ONE IN ACCORDANCE WITH R905.1.1.
3.
AN ICE BARRIER SHALL BE INSTALLED THAT IS WITHIN COMPLIANCE OF R905.1.2
OF THE 2015 IRC OF NYS. THE ICE BARRIER SHALL CONSIST OF NOT FEWER THAN
TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER, OR A SELF-ADHERING
POLYMER-MODIFIED BITUMEN SHEET SHALL BE USED IN PLACE OF NORMAL
UNDERLAYMENT & EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES
TO A POINT NOT LESS THAN 24 INCHES INSIDE THE EXTERIOR WALL LINE OF THE
BUILDING. IN THE CASE OF A ROOF WHOSE SLOPE IS 8/12 OR GREATER, THE ICE
BARRIER SHALL ALSO BE APPLIED NOT LESS THAN 36 INCHES MEASURED ALONG
THE ROOF SLOPE FROM THE EAVE EDGE OF THE BUILDING.
4.
FLASHING MATERIALS ARE TO BE CORROSION RESISTENT AND INSTALLED IN
ACCORDANCE WITH R703.4, R903.2 AND R905.2.8.
5.
HOUSE WRAP MATERIAL OR BUILDING FELT AND ITS INSTALLATION ARE TO
COMPLY WITH R703.2.
6.
WEATHER RESISTANT SIDING THICKNESS AND ATTACHMENT SHALL BE IN
ACCORDANCE WITH TABLE 703.3(1), THE REQUIREMENTS OF 703.3 AND THE
MANUFACTURES SPECIFICATIONS. CLADDING ATTACHMENT OVER FOAM
SHEATHING TO COMPLY WITH THE LIMITATIONS OF R703.15 & R703.17.
BUILDING IS OR BUILDING IS NOT WITHIN ONE MILE OF TIDAL WATERS
CONSTRUCTION METHOD: PERSPECTIVE PERFORMANCE ENERGY RATING INDEX
BLOWER DOOR TEST MECHANICAL VENT TEST DUCT LEAKAGE TEST
ENERGY COMPLIANCE NOTES:
1.
EQUIPMENT SHALL MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF TABLES
C403.2.3(1), C403.2.3(2), 403.2.3(3), 403.2.3(4), 403.2.3(5), 403.2.3(6), 403.2.3(7), 403.2.3(8) &
403.2.3(9) WHEN TESTED AND RATED IN ACCORDANCE W/ THE APPLICABLE TEST
PROCEDURE.
2.
ALL CONSTRUCTION SHALL COMPLY w/ THE 2020 INTERNATIONAL ENERGY
CONSERVATION CONSTRUCTION CODE. THE AUTHORITY HAVING JURISDICTION SHALL
BE PERMITTED TO DETERMINE AN ENERGY EFFICIENCY PROGRAM TO EXCEED THE
ENERGY EFFICIENCY REQ'D BY THIS CODE.
3.
A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER AND POSTED ON
A WALL IN THE SPACE WHERE THE FURNACE IS LOCATED. CERTIFICATE SHALL COMPLY
w/IRC N1101.14
4.
ATTIC OR CRAWL SPACE ACCESS SHALL BE WEATHERSTRIPPED AND INSULATED TO A
LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES.
5.
INSTALLATION - THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE SHALL BE
INSTALLED IN ACCORDANCE w/ THE CRITERIA LISTED IN TABLE 402.4.1.1 WHERE REQ'D
BY CODE OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL COMPONENTS &
VERIFY COMPLIANCE.
6.
TESTING - BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERFIRED HAVING
LESS THAN OR EQUAL TO 3 ACH50 IN CZ 4A, 5, 6A. TESTING SHALL BE CONDUCTED BY
AN APPROVED THIRD PARTY.
7.
DUCTS - SUPPLY & RETURN DUCTS IN ATTICS SHALL BE INSULATED TO A MINIMUM OF
R-8 @ 3" OR GREATER IN DIAMETER , AND R-6 @ DUCTS LESS THAN 3" IN DIAMETER.
8.
DUCT SEALING - DUCTS, AIR HANDLERS & FILTER BOXES SHALL BE SEALED.
9.
DUCT TESTING - DUCTS SHALL BE PRESSURE TESTED TO DETERMINE AIR LEAKAGE BY
AN APPROVED THIRD PARTY.
10.
BUILDING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS.
11.
BE INSULATED WITH R-3 MINIMUM.
12.
MECHANICAL VENTILATION - SHALL MEET THE REQUIREMENTS OF THE IRC/ IMC
13.
EQUIPMENT SIZING - PER ACCA MANUAL S, BASED ON LOADS CALCULATED PER ACCA
MANUAL J AS PROVIDED BY A THIRD PARTY HERS RATER.
14.
LIGHTING - A MIN. OF 75% OF PERMANENTLY INSTALLED FIXTURES MUST HAVE
HIGH-EFFICIENCY LAMPS.
15.
ALL HVAC, PLUMBING & ELECTRICAL SYSTEMS SHALL MEET THE IRC CHAPTER 11
ENERGY EFFICIENCY, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL ENERGY
CONSERVATION CODE. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR TO SUBMIT IN DETAIL THE DESIGN, CALCULATIONS, DRAWINGS,
WRITTEN STATEMENTS OF THE MECHANICAL, AIR CONDITIONING, VENTILATION,
HEATING SYSTEMS (NEW, EXISTING OR UPGRADED) STAMPED BY A PROFESSIONAL
ENGINEER IF REQ'D BY THE OWNER OR BUILDING DEPT.
16.
ADDITIONS, ALTERATIONS OR RENOVATION SHALL COMPLY w/ IECC 2020. UNALTERED
PORTIONS OF THE EXISTING BUILDING IS NOT REQUIRE TO COMPLY w/ THIS CODE.
17.
MINIMUM ONE PROGRAMMABLE THERMOSTAT SHALL BE PROVIDED FOR EACH
SEPARATE HEATING & COOLING SYSTEM IN ACCORDANCE w/ SECTION N1103 CONTROL
SYSTEMS.
18.
ALL EXTERIOR WALL/FLOOR/CEILING JOIST SHALL BE AIR SEALED & INSULATED IN
ACCORDANCE w/ TABLE R402.4.1.1 APPLY A FRESH BEAD OF CAULK TO THE TOP &
BOTTOM PLATE IMMEDIATLY PRIOR TO INSTALLING INTERIOR GYP. WALL BOARD.
GUARDS & WINDOW FALL PROTECTION:
R312.1 GUARDS - GUARDS SHALL BE PROVIDED IN ACCORDANCE w/SECTIONS R312.1.1
THROUGH R312.1.4.
R312.1.1 WHERE REQUIRED - GUARDS REQUIRED ALONG OPEN-SIDED WALKING
SURFACES, INCLUDING STAIRS, RAMPS & LANDINGS, THAT ARE LOCATED MORE THAN 30
INCHES VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT 36 INCHES
HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING IS NOT AN
ACCEPTABLE GUARD.
R312.1.2 HEIGHT - REQUIRED GUARDS AS DESCRIBED ABOVE SHALL NOT BE LESS THAN
36 INCHES IN HEIGHT MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE
OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS.
EXCEPTIONS:
1. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT OF 34 INCHES
MEASURED VERTICALLY FROM A LINE CONNECTION THE LEADING EDGES OF THE
TREADS.
2. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDES OF THE
STAIRS, THE TOP OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES AND NOT MORE
THAN 38 INCHES AS MEASURED VERTICALLY ROM A LINE CONNECTING THE LEADING
EDGES OF THE TREADS.
R312.1.3 OPENING LIMITATIONS - REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT
ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
EXCEPTIONS:
1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF A STAIR, FORMED BY A RISER,
TREAD & BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6
INCHES IN DIAMETER.
2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW
PASSAGE OF A SPHERE 43
8" IIN DIAMETER
R312.1.4 EXTERIOR PLASTIC COMPOSITE GUARDS - PLASTIC COMPOSITE EXTERIOR
GUARDS SHALL COMPLY w/ THE REQUIREMENTS OF SECTION R317.4.
R312.2 WINDOW FALL PROTECTION - WINDOW FALL PROTECTION SHALL BE PROVIDED IN
ACCORDANCE w/ SECTIONS R312.2.1 & R12.2.2.
32"
2"
-GENERAL NOTES
-SITE LOCATION
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
GLAZING NOTES:
FRAMING NOTES:
DESIGN CRITERIA:
FROST LINE DEPTH
TERMITE AREA
ICE SHIELD
DECAY AREA
WINTER DESIGN TEMP
SEISMIC DESIGN CATEGORY
WIND EXPOSURE CATEGORY
WEATHERING AREA
GROUND SNOW LOAD
FROM WEATHER, ETC. (VERIFY DETAILS)
PANELS. PREDRILL HOLES F/ HARDWARE, PROV. PLASTIC INSERTS TO PROTECT
OPTION: PROV. 1"x4" PICTURE-FRAME TRIM (ALUM. CLAD) TO ATTACH STRUCT.
WITH OWNER.
BUILDER TO VERIFY & CONFORM TO ALL REQUIREMENTS. REVIEW OPTIONS
BY CODE OR USE: STRUCTURAL PANELS FOR STORM PROTECTION-
INSUL. GLASS, IMPACT RESISTANT & DESIGN PRESSURE RATED AS REQ'D
WINDOWS / SL. GL. DOORS AS MANUF. BY MARVIN, INTEGRITY W/
CONNECTORS BY SIMPSON (OR EQUAL).
6. ALL FLUSH WD. CONNECTIONS TO BE FASTENED W/ RATED GALV. METAL
5. PROVIDE DOUBLE FRAMING UNDER ALL POSTS & PARALLEL PARTITIONS.
4. USE SOLID BLOCKING OR X- BRACING BETWEEN ALL JOISTS @ 8'-0" MAX. SPACING.
ALONG EDGES & 6" O.C. IN FIELD W/ SOLID BLKG. UNDER ALL SEAMS.
PERIMETER PANELS AT EDGE OF ROOF & WALL CORNERS TO BE NAILED @ 4" O.C.
3. ALL SHEATHING TO BE AP.A. RATED, EXPOSURE 1, 1/2" MIN. THICKNESS.
2. ALL EXTERIOR FRAMING TO BE STRUCTURAL GRADE CCA TREATED LUMBER.
STRUCTURAL GRADE NO. 2 OR BETTER.
1. ALL FRAMING LUMBER TO BE GRADE STAMPED DOUGLAS FIR-LARCH
R308 GLAZING AT HAZARDOUS LOCATIONS SHALL HAVE GLAZING PROTECTION IN
CONFORMANCE WITH R308. IN GENERAL, GLAZING IN ALL DOORS AND FIXED SIDE
PANELS, GLAZINGS LESS THAN 60" ABOVE SURFACES OF TUBS SHOWERS, ETC.
GLAZING WITHIN 24" ARC OF DOORS IN CLOSED POSITION WITH SILLS LESS THAN 60"
ABOVE FLOOR. GLAZINGS OVER 9 SQUARE FEET AND LESS THAN 18" ABOVE FINISHED
FLOOR. GLAZING NEAR STAIRWAYS/LANDINGS. SEE COMPLETE TEXT OF R308.4.
GLAZING FOR SPECIFICS ON LOCATIONS AND EXCEPTIONS.
R308.6 SKYLIGHTS AND SLOPED GLAZING SHALL COMPLY WITH THIS SECTION AND
HAVE FULLY TEMPERED GLAZING.
R309 GARAGE OPENING PROTECTION AND SEPARATION REQUIRED TO BE AS NOTED
AND IN CONFORMANCE WITH R309. GARAGE FLOOR SURFACES SHALL BE SLOPED TO
FACILITATE THE MOVEMENT OF LIQUIDS TO DRAIN TOWARD THE MAIN VEHICLE
ENTRY DOORWAY.
R310.1.1 ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM
NET CLEAR OPENING OF 5.7 SQUARE FEET. 24" MINIMUM CLEAR OPENING HEIGHT, 20"
MINIMUM CLEAR OPENING WIDTH, 44" MAX STILL HEIGHT.
FINAL, INSTALLED STAIRWAYS, HANDRAILS, GUARDS SHALL BE INSTALLED IN FULL
CONFORMANCE WITH THIER RESPECTIVE CODE SECTIONS. ARCHITECT IS NOT
RESPONSIBLE FOR THESE INSTALLATIONS.
R314 STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL
POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED
HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES ON
EITHER SIDEOF THE STAIRWAY AND THE MINIMUM CLEAR WIDTH OF THE STAIRWAY
AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL
NOT BE LESS THAN 31.5 INCHES WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND
27 INCHES WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. THE MAXIMUM RISER
HEIGHT SHALL BE 8.25" AND THE MINIMUM TREAD DEPTH SHALL BE 9" IN
CONFORMANCE WITH R314.2. MINIMUM HEADROOM 6'-8'. ALL STAIRS SHALL BE
PROVIDED WITH ILLUMINATION IN ACCORDANCE WITH SECTION R303.4. ENCLOSED
ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND
ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH GYPSUM BOARD.
R315.1 HANDRAILS HAVING A MINIMUM AND MAXIMUM HEIGHTS OF 34 INCHES AND 38
INCHES, RESPECTIVELY, MEASURED VERTICALLY FROM THE NOSING OF THE TREADS
SHALL BE PROVIDED ON AT LEAST ONE SIDE OF STAIRWAYS. ALL REQUIRED
HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS WITH TWO OR
MORE RISERS FROM A POINT DIRECTLY ABOVE THE TOP RISER OF A FLIGHT TO A
POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. ENDS SHALL BE
RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.
HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPCE OF NOT LESS THAN 1.5
INCHES (38MM) BETWEEN THE WALL AND THE HANDRAIL. THE HANDGRIP PORTION OF
HANDRAILS SHALL HAVE A CIRCULAR CROSS SECTION OF 1-1/4 INCHES MINIMUM TO
2-5/8 INCHES MAXIMUM. EDGE RADIUS OF 1/8".
R316.1 GUARDS ARE TO BE A MINIMUM OF 36 INCHES (914MM) IN HEIGHT. OPEN SIDES
OF STAIRS WITH A TOTAL RISE OF MORE THAN 30 INCHES ABOVE THE FLOOR OR
GRADE BELOW SHALL HAVE GUARDS (EACH SIDE) NOT LESS THAN 34 INCHES IN
HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. (SECOND
STORY GUARDS ARE RECOMMENDED TO BE HIGHER.)
R317.1 SINGLE AND MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED IN EACH
SLEEPING ROOM, OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
VICINITY OF THE BEDROOM, ON EACH ADDITIONAL STORY OF THE DWELLING,
INCLUDING BASEMENTS. THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH
A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS
IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS
OVER BACKROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. ALL
SMOKE ALARMS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THE
PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIREWARNING EQUIPMENT
PROVISIONS OF NFPA72.
R319.1.2 WALL AND CEILING FINISHES NOT INCLUDING TRIM, DOOR, AND WINDOW
FRAMES SHALL HAVE A FLAME-SPREAD CLASSIFICATION OF NOT GREATER THAN 200.
WALL AND CEILING FINISHES SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT
GREATER THAN 450.
R322. A VAPOR RETARDER SHALL BE INSTALLED ON THE WARM-IN-WINTER SIDE OF
INSULATION.
R1001.1 MASONRY CHIMNEYS SHALL BE CONSTRUCTED, ANCHORED, SUPPORTED,
AND REINFORCED AS REQUIRED IN THIS CHAPTER AND THE APPLICABLE PROVISIONS
OF CHAPTERS 3, 4, AND 6 WITH APPLICABLE CLEARANCES TO COMBUSTIBLES AND
FIRESTOPPING.
R807.1 ATTIC ACCESS. AN ATTIC ACCESS OPENING SHALL BE PROVIDED TO ATTIC
AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES
OR GREATER. THE ROUGH-FRAMED OPENINH SHALL NOT BE LESS THAN 22 INCHES
BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY
ACCESSIBLE LOCATION. A 30-INCH MINIMUM UNOBSTRUCTED HEADROOM IN THE
ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING.
SEE SECTION M1305.1.3 FOR ACCESS REQUIREMENTS WHERE MECHANICAL
EQUIPMENT IS LOCATED IN ATTIC.
R808.1 COMBUSTIBLE INSULATION SHALL BE SEPARATED A MINIMUM OF 3 INCHES
FROM RECESSED LIGHTING FIXTURES, FAN MOTORS, AND OTHER HEAT-PRODUCING
DEVICES OR SEPARATED IN ACCORDANCE WITH THE CONDITIONS STIPULATED IN
THE FIXTURES LISTING. RECESSED LIGHTING INSTALLED IN THE BUILDING THERMAL
ENVELOPE SHALL MEET THE REQUIREMENTS OF SECTION N1101.3.
CODE REFERENCE NOTES:
B ( SUBURBAN, SEMI-WOODED)
3'-0"
YES
MODERATE TO HEAVY
SLIGHT TO MODERATE
SEVERE
C
130 MPH (3 SECOND GUST)
20 PSF
AND @ 12" O.C. F/ SPANS BETWEEN 6 & 8 FEET.
2 1/2" NO.8 WD. SCREWS @ 16" O.C. F/ SPANS UP TO 6 FEET,
PROVIDE PRECUT, PREDRILLED PLYWOOD, 7/16" THICK.
INCLUDE ATTACHMENT HARDWARE:
AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA)
WOOD FRAME CONSTRUCTION MANUAL FOR
1.
ALL ELECTRIC WORK SHALL COMPLY WITH THE NATIONAL ELECTRICE CODE. ELECTRICIAN
SHALL OBTAIN FIRE UNDERWRITERS CERTIFICATE FOR ALL ELECTRIC WORK AND SHALL SUBMIT TO
OWNER. PROVIDE ALL OUTLETS AND JUNCTION BOXES REQUIRED FOR ALL APPLIANCES, PUMPS,
EQUIPMENT, ETC. CONTRACTOR SHALL REVIEW SERVICE REQUIREMENTS, ALL LIGHTING, OUTLETS,
FIXTURES, PHONE JACKS, T.V. CABLE JACKS, ETC. WITH OWNER AS REQUIRED FOR THE FULL
INSTALLATION AND SATISFACTION OF OWNERS REQUIREMENTS AND CODE COMPLIANCE AND
SHALL PROVIDE SAME. ARCHITECT IS NOT RESPONSIBLE FOR ELECTRICAL DESIGNS FOR THIS
PROJECT IN ANY CAPACITY.
2.
ALL PLUMBING WORK SHALL COMPLY WITH THE NATIONAL PLUMBING CODE AND ALL LOCAL
CODES. CONTRACTOR SHALL REVIEW WITH THE OWNER THE REQUIREMENTS FOR PLUMBING
INSTALLATIONS INCLUDING BUT NOT LIMITED TO FIXTURES, TRIM, ACCESSORIES, ETC. AND
REQUIREMENTS FOR WATER SERVICE AND DOMESTIC HOT WATER. ARCHITECT IS NOT
RESPONSIBLE FOR ANY PLUMBING SYSTEMS IN ANY CAPACITY. CONTRACTOR SHALL PROVIDE
SANITARY SYSTEM IN ACCORDANCE WITH THE OWNERS APPROVED SITE PLAN AND SHALL
COORDINATE ALL INSPECTIONS REQUIRED FOR APPROVAL OF SAME. AND SURVEYS INDICATING
FINAL TANK LOCATIONS SHALL BE BY OWNERS SURVEYOR. CONTRACTOR SHALL PROVIDE
SURVEYOR WITH INFORMATION AS REQUIRED.
3.
ALL H.V.A.C. WORK SHALL COMPLY WITH ARTICLE 10 OF THE N.Y.S. UNIFORM FIRE
PREVENTION AND BUILDING CODE AND ENERGY CODE. CONTRACTOR SHALL REVIEW ALL
MECHANICAL SYSTEMS WITH OWNER FOR TYPE OF SYSTEM TO BE PROVIDED (I.E. OIL, GAS, OR
ELECTRIC HOT WATER OR AIR, ETC.) INCLUDING AIR CONDITIONING REQUIREMENTS. ARCHITECT IS
NOT RESPONSIBLE FOR HEATING OR AIR CONDITIONING SYSTEMS IN ANY CAPACITY.
4.
OWNER SHALL OBTAIN ANY AND ALL REQUIRED PERMITS PRIOR TO ALLOWING
CONTRACTORS TO PROCEED WITH ANY OF THE WORK.
5.
ALL SITE WORK INCLUDING SANITARY SYSTEM, UTILITIES, EASEMENTS. SETBACKS,
ELEVATIONS, DRAINAGE, RETAINING WALLS, ETC. SHALL BE IN ACCORDANCE WITH A SITE PLAN
PREPARED BY THE OWNERS SURVEYOR. THE ARCHITECT IS NOT RESPONSIBLE FOR SITE DESIGNS
OF ANY TYPE IN ANY CAPACITY.
6.
ALL WORK SHALL BE PERFORMED BY LICENSED CONTRACTORS WHOM ARE EXPERIENCED
WITH THE TYPE OF WORK BEING PERFORMED. ALL CONTRACTORS SHALL MAINTAIN LIABILITY
INSURANCE AND WORKERS COMPENSATION INSURANCE IN CONNECTION WITH ALL WORK BEING
PERFORMED IN PROJECT.
7.
ALL MATERIALS, SYSTEMS, EQUIPMENT, FIXTURES, ETC. SHALL BE INSTALLED IN STRICT
COMPLIANCE WITH THE MANUFACTURERS WRITTEN SPECIFICATIONS AND INSTALLATION
INSTRUCTIONS INCLUDING ALL CLEARANCES FOR SERVICE, ETC.
8.
ALL CONTRACTORS SHALL WARRANT THEIR WORK IN WRITING TO THE OWNER FOR A
MINIMUM PERIOD OF TWO YEARS.
9.
THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE
RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR
PROCEDURES, OR FOR SAFETY PROGRAMS IN CONNECTION WITH THE WORK OR FOR ACTS OR
OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR ANY PERSON PERFORMING ANY OF THE
WORK, OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH
THE INTENT OF THE CONTRACT DOCUMENTS IN THAT SAID RESPONSIBILTY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
10.
ALL EXTERIOR DOORS, ROOFING SHINGLES, TRIM, SIDING, ETC. SHALL BE REVIEWED AND
APPROVED BY OWNER.
11.
ALL INTERIOR FINISHES INCLUDING BUT NOT LIMITED TO WALLS, FLOORING, TILE, ETC. SHALL
BE REVIEWED WITH AND APPROVED BY OWNER.
12.
ALL MISCELLANEOUS INTERIOR ITEMS INCLUDING BUT NOT LIMITED TO DOORS, TRIM,
FIREPLACES. CLOSET SHELVING, KITCHEN CABINETS, SHELVING. HARDWARE, ETC. SHALL BE
REVIEWED WITH AND APPROVED BY OWNER.
13.
WHERE EXISTING WALLS, POSTS ETC. ARE REMOVED IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO PROVIDE TEMPORARY SUPPORT, SHORING, BRACING, ETC. AS REQUIRED.
CLIMATIC & GEOGRAPHIC
ONE AND TWO- FAMILY DWELLINGS. (2018 EDITION)
WIND SPEED :
TABLE R602.3(1)
FASTENING SCHEDULE
ITEM
DESCRIPTION OF BUILDING ELEMENTS
NUMBER AND TYPE
OF FASTENER
a, b, c
SPACING AND LOCATION
Roof
Blocking between ceiling joists or rafters
to top plate
4-8d box (2 1/2" × 0.113") or
3-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
3-3" × 0.131" nails
Toe nail
Ceiling joists to plate
4-8d box (2 1/2" × 0.113"); or
3-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
3-3" × 0.131" nails
Per joist, toe nail
Ceiling joist not attached to parallel rafter,
laps over partitions (see Section R802.5.2
and Table R802.5.2)
4-10d box (3”x0.128”);or
3-16d common (3 ½” x 0.162”);or
4-3”x0.131” nails
Face nail
Ceiling joist attached to parallel rafter
(heel joint) (see Section R802.5.2 and
Table R802.5.2)
Table R802.5.2
Face nail
Collar tie to rafter, face nail or 1 1/4" × 20
ga. ridge strap to
rafter"
4-10d box (3" × 0.128"); or
3-10d common (3" × 0.148"); or
4-3" × 0.131" nails
Face nail each rafter
Rafter or roof truss to plate
3-16d box nails (3 1/2" × 0.135"); or
3-10d common nails (3" × 0.148"); or
4-10d box (3" × 0.128"); or
4-3" × 0.131" nails
Roof rafters to ridge, valley or hip rafters
or roof rafter to minimum 2” ridge beam
4-16d (31/2" × 0.135"); or
3-10d common (3" × 0.148"); or
4-10d box (3" × 0.128"); or
4-3" × 0.131" nails
Toe nail
3-16d box 3 1/2" × 0.135"); or
2-16d common (3 1/2" × 0.162"); or
3-10d box (3" × 0.128"); or
3-3" × 0.131" nails
End nails
Wall
Stud to stud (not at braced wall panels)
16d common (3 ½ " × 0.162")
24" o. c. face nail
10d box (3" × 0.128"); or
3" × 0.131" nails
16” o. c. face nail
Stud to stud and abutting studs at
intersecting wall corners
(at braced wall panels)
16d box (3 ½ "× 0.135"); or
3” x 0.131” nails
12" o.c. face nail
16d common (3 ½” x 0.162”)
16” o.c. face nail
Built-up header (2" to 2" header with 1/2"
spacer)
16d common (3 ½” x 0.162”)
16" o.c. each edge face nail
16d box (3 ½” x 0.135”)
12” o.c. each edge face nail
Continuous header to stud
5-8d box (2 1/2" × 0.113"); or
4-8d common(2 1/2" × 0.131"); or
4-10d box (3" × 0.128")
Toe nail
Adjacent full-height stud to end of header
16d common (3 1/2" × 0.162")
16" o.c. face nail
10d box (3" × 0.128"); or
3" × 0.131" nails"
12" o.c. face nail
Top plate to top plate
8-16d common (3 1/2" × 0.162"); or
12-16d box (3 1/2" × 0.135"); or
12-10d box (3" × 0.128"); or
12-3" × 0.131" nails
Face nail on each side of end joint
(minimum 24" lap splice length each
side of end joint)
Bottom plate to joist, rim joist, band joist
or
blocking (not at braced wall panels)
16d common (3 1/2" × 0.162")
16" o.c. face nail
16d box (3 1/2" × 0.135"); or
3" × 0.131" nails
12" o.c. face nail
Bottom plate to joist, rim joist, band joist
or
blocking (at braced wall panel)
3-16d box (3 1/2" × 0.135"); or
2-16d common (3 1/2" × 0.162"); or
4-3" × 0.131" nails
3 each 16" o.c. face nail
2 each 16" o.c. face nail
4 each 16" o.c. face nail
Top or bottom plate to stud
4-8d box (2 1/2" × 0.113"); or
3-16d box (3 1/2" × 0.135"); or
4-8d common (2 1/2" × 0.131"); or
4-10d box(3" × 0.128"); or
4-3" × 0.131" nails
Toe nail
3-16d box (3 1/2" × 0.135"); or
2-16d common (3 1/2" × 0.162"); or
3-10d box (3" × 0.128"); or
3-3" × 0.131" nails
End nail
Top plates, laps at corners and
intersections
3-10d box (3" × 0.128"); or
2-16d common (3 1/2" × 0.162"); or
3-3" × 0.131" nails
Face nail
1" brace to each stud and plate
3-8d box (2 1/2" × 0.113"); or
2-8d common (2 1/2" × 0.131"); or
2-10d box (3" × 0.128"); or
2 staples 1 3/4
Face nail
1"× 6" sheathing to each bearing
3-8d box (2 1/2" × 0.113"); or
2-8d common (2 1/2" × 0.131"); or
2-10d box (3" × 0.128"); or
2 staples 1 3/4"
Face nail
1"× 8" and wider sheathing to each
bearing
3-8d box (2 1/2" × 0.113"); or
3-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
3 staples, 1" crown, 16 ga., 1 3/4" long
Face nail
Wider than 1" × 8"
4-8d box (2 1/2" × 0.113"); or
3-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
4 staples, 1" crown, 16 ga., 1 3/4" long
Floor
Joist to sill, top plate or girder
4-8d box (2 1/2" × 0.113"); or
3-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
3-3" × 0.131" nails
Toe nail
Rim joist, band joist or blocking to sill or
top
plate (roof applications also)
8d box (2 1/2" × 0.113")
4” o.c. toe nail
8d common (2 1/2" × 0.131"); or
10d box (3" × 0.128"); or
3" × 0.131" nails
6" o.c. toe nail
1" × 6" subfloor or less to each joist
3-8d box (2 1/2" × 0.113"); or
2-8d common (2 1/2" × 0.131"); or
3-10d box (3" × 0.128"); or
2 staples, 1"" crown, 16 ga., 1 3/4" long
Face nail
2" subfloor to joist or girder
3-16d box (3 ½” x 0.135”)
2-16d common (3 ½ ” x 0.162”)
Blind or face nail
2" planks (plank & beam - floor & roof)
3-16d box (3 ½ " × 0.135"); or
2-16d common (3 ½” x 0.162”)
At each bearing
Band or rim joist to joist
3-16d common (3 ½” x 0.162”)
4-10 box (3” x 0.128”), or
4-3” x 0.131” nails, or
4-3” x 14 ga. staples, 7/16” crown
End nail
Built-up girders and beams, 2-inch lumber
layers
20d common (4” x 0.192”); or
Nail each layer as follows: 32” o.c. at
top and bottom and staggered.
10d box (3” x 0.128”); or
3” x 0.131” nails
24” o.c. face nail at top and bottom
staggered on opposite sides.
And:
2-20d common (4” x 0.192?; or 3-10d
box(3 ½” x 0.128”); or
3-3” x 0.131” nails
Face nail at ends and at each
splice
Ledger strip supporting joists or rafters
4-16d box (31/2" × 0.135"); or
3-16d common (31/2" × 0.162"); or
4-10d box (3" × 0.128"); or
4-3" × 0.131" nails
At each joist or rafter, face
nail
Bridging to joist
2-10d box (3" × 0.128"), or 2-8d
common
(21/2" × 0.131"; or 2-3" × 0.131") nails
Each end, toe nail
ITEM
DESCRIPTION
OF BUILDING ELEMENTS
NUMBER AND
TYPE OF FASTENER
a, b, c
SPACING OF FASTENERS
Edges
(inches)h
Intermediate
supports c, e
(inches)
Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing
[see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing]
3/8" - 1/2"
6d common (2"" × 0.113"") nail
(subfloor, wall)
i
8d common (2 1/2" × 0.131") nail
(roof); or RSRS-01 (2 3/8" × 0.113")
nail(roof)
12f
19/32" - 1"
8d common nail (2 1/2" × 0.131"); or
RSRS-01; (2” x 0.113”) nail (roof)
j
12f
1 1/8" - 1 1/4"
10d common (3" × 0.148") nail; or
8d (2 1/2" × 0.131") deformed nail
Other wall sheathing
g
1/2" structural cellulosic fiberboard
sheathing
1 1/2" galvanized roofing nail, 7/16"
head diameter, or 1 1/4" long 16 ga.
staple with 7/16" or 1" crown
25/32" structural cellulosic fiberboard
sheathing
1 3/4" galvanized roofing nail, 7/16"
head diameter, or 1 1/2" long 16 ga.
staple with 7/16" or 1" crown
1/2" gypsum sheathing d
1 1/2" galvanized roofing nail; staple
galvanized, 1 1/2" long; 11/4 screws,
Type W or S
5/8" gypsum sheathing d
1 3/4" galvanized roofing nail; staple
galvanized, 1 5/8" long; 1 5/8”screws,
Type W or S
Wood structural panels, combination subfloor underlayment to framing
3/4" and less
6d deformed (2" × 0.120") nail; or
8d common (21/2" × 0.131") nail
7/8" - 1"
8d common (2 1/2" × 0.131") nail; or
8d deformed (2 1/2" × 0.120") nail
1 1/8" - 1 1/4"
10d common (3" × 0.148") nail; or
8d deformed (2 1/2" × 0.120") nail
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; 1 ksi = 6.895 MPa.
a. Nails are smooth-common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall
have minimum average bending yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for
shank diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 ksi for shank diameters of 0.142 inch or less.
b. Staples are 16 gage wire and have a minimum 7/16-inch on diameter crown width.
c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater.
d. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically.
e. Spacing of fasteners not included in this table shall be based on Table R602.3(2)
f. For wood structural panel roof sheathing attached to gable end roof framing and to intermediate supports within 48 inches of roof edges and
ridges, nails shall be spaced at 6 inches on center where the ultimate design wind speed is less than 130 mph and shall be spaced 4 inches on
center where the ultimate design wind speed is 130 mph or greater but less than 140 mph.
g. Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to
ASTM C208.
h. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor
perimeters only. Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required
blocking. Blocking of roof or floor sheathing panel edges perpendicular to the framing members need not be provided except as required by
other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking.
i. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter
and toe nails from the ceiling joist to top plate in accordance with this schedule. The toe nail on the opposite side of the rafter shall not be
required.
j. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667.
2 toe nails on one side and 1
toe nail
on opposite side of each
rafter or trussi
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
FOR SI: 1 LB/SQFT = 0.0479 KN/M.
1 MILE PER HR = 1.609 KM/HR.
A. WEATHERING MAY REQUIRE A HIGHER STRENGTH CONCRETE OR GRADE OF MASONRY THAN NECESSARY TO SATISFY THE STRUCTURAL
REQUIREMENTS OF THIS CODE. THE WEATHERING COLUMN
SHALL BE FILLED IN WITH THE WEATHERING INDEX (I.E., "NEGLIGIBLE", "MODERATE", OR "SEVERE") FOR CONCRETE AS DETERMINED FROM THE
WEATHERING PROBABILITY MAP [FIGURE R301.2(3)].
THE GRADE OF MASONRY UNITS SHALL BE DETERMINED FROM ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 216, OR C 652.
B. THE FROST LINE DEPTH MAY REQUIRE DEEPER FOOTINGS THAN INDICATED IN FIGURE R403.1(1). THE JURISDICTION SHALL FILL IN THE FROST LINE
DEPTH COLUMN WITH THE MINIMUM
DEPTH OF FOOTING BELOW FINISH GRADE.
C. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "VERY HEAVY", "MODERATE TO HEAVY", "SLIGHT TO MODERATE", OR "NONE TO SLIGHT" IN
ACCORDANCE WITH FIGURE
R301.2(6) DEPENDING ON WHETHER THERE HAS BEEN A HISTORY OF LOCAL DAMAGE.
D. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "MODERATE TO SEVERE", "SLIGHT TO MODERATE", OR "NONE TO SLIGHT" IN
ACCORDANCE WITH FIGURE R301.2(7)
DEPENDING ON WHETHER THERE HAS BEEN A HISTORY OF LOCAL DAMAGE.
E. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE WIND SPEED FROM THE BASIC WIND SPEED MAP [FIGURE F301.2(4)]. WIND
EXPOSURE CATEGORY SHALL BE
DETERMINED ON A SITE-SPECIFIC BASIS IN ACCORDANCE WITH SECTION R301.2.1.4
F. REFER TO TABLE N1101.2 "WINTER DESIGN DRY-BULB TEMPERATURE" COLUMN.
G. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE SEISMIC DESIGN CATEGORY DETERMINED FROM SECTION R301.2.2.1
H. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH (A) THE DATE OF THE JURISDICTION'S ENTRY INTO THE NATIONAL FLOOD INSURANCE
PROGRAM (DATE OF ADOPTION OF THE FIRST
CODE OR ORDINANCE FOR MANAGEMENT OF FLOOD HAZARD AREAS). (B) THE DATE(S) OF THE CURRENTLY EFFECTIVE FIRM AND FBFM, OR OTHER
FLOOD HAZARD MAP ADOPTED BY THE
COMMUNITY, AS MAY BE AMENDED.
I.
SEE FIGURE R301.2(5) FOR GROUND SNOW LOADS.
TABLE 3.2A SILL OR BOTTOM PLATE
TO FOUNDATION ANCHOR BOLT CONNECTIONS
1/2" ANCHOR
BOLTS
5/8" ANCHOR
BOLTS
Fastest-Mile
Wind Speed
(mph)
Fastest-Mile
Wind Speed
(mph)
Anchor Bolt
Connection
Foundation
Supporting
Bracing Wall Perimeter
Edge Nail Spacing (in.)
Sill Plate to Foundation*
(crawl space or basement)
Wall Bottom Plate to
Foundation (slab on grade)
1 Story
2 Stories
3 Stories
1-3 Stories
All
Maximum Anchor
Bolt Spacing (in.)
Maximum Anchor
Bolt Spacing (in.)
ANCHORAGE REQUIRED TO RESIST LATERAL LOADS SHALL BE DETERMINED IN THE FOUNDATION DESIGN
PER SECTION 1.1.4.
ANCHOR BOLT SPACINGS BASED ON MAXIMUM SHEAR CAPACITY OF UNBLOCKED ROOF AND/OR FLOOR
DIAPHRAGMS (279 PLF.)
ANCHOR BOLT SPACINGS BASED ON MAXIMUM SHEAR CAPACITY OF BRACING WALL PERIMETER EDGE NAIL
SPACING OF 3" O.C.
(731 PLF.) BUILT IN ACCORDANCE WITH SECTION 3.4.4.
ANCHOR BOLT SPACINGS BASED ON MAXIMUM SHEAR CAPACITY OF BRACING WALL PERIMETER EDGE NAIL
SPACING OF 6" O.C.
(421 PLF.) BUILT IN ACCORDANCE WITH SECTION 3.4.4.
*
1)
3)
2)
7" MIN. EMBEDMENT IN POURED CONCRETE
15" MIN. EMBEDMENT IN C.M.U.
FILL TOP 2 COURSES SOLID.
PROVIDE 3"x3" WASHERS
STRUCTURAL MEMBER
ALLOWABLE
DEFLECTION
RAFTERS HAVING SLOPES GREATER THAN 3/12
WITH NO FINISHED CEILING ATTACHED TO RAFTERS
L/180
INTERIOR WALLS AND PARTITIONS
H/180
FLOORS AND PLASTERED CEILINGS
L/360
ALL OTHER STRUCTURAL MEMBERS
L/240
EXTERIOR WALLS WITH PLASTER OR STUCCO FINISH
L/360
EXTERIOR WALLS-WIND LOADS WITH BRITTLE FINISH
L/240
EXTERIOR WALLS-WIND LOADS WITH FLEXIBLE FINISH
L/120
TABLE R301.6
ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS
1. NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6 INCHES ON-CENTER AT THE PANEL EDGE. IF WALL
SHEATHING IS NAILED 3 INCHES ON-CENTER AT THE PANEL EDGE TO OBTAIN HIGHER SHEAR CAPACITIES, NAILING REQUIREMENTS
FOR STRUCTURAL MEMBERS SHALL BE DOUBLED, OR ALTERNATE CONNECTORS, SUCH AS SHEAR PLATES, SHALL BE USED TO
MAINTAIN THE LOAD PATH.
2. WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF NAILS SHALL
BE PERMITTED TO BE REDUCED TO
3. CORROSION RESISTANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE PERMITTED, CHECK IBC FOR ADDITIONAL
REQUIREMENTS. 1-16D NAIL PER FOOT.
WIND
GROUND
SNOW
LOAD
i
SUBJECT TO DAMAGE FROM
1,2
SPEED
(MPH)
e
SEISMIC
DESIGN
CATEGORY g
WEATHERINGa
FROST
LINE
DEPTH
TERMITE
c
DECAY
d
WINTER
DESIGN
TEMP F
(36" FROM
SOFFIT)
ICE SHIELD
UNDER-
LAYMENT
REQUIRED
FLOOD
HAZARDS
h
B
SEVERE
36"
MODERATE
TO HEAVY
SLIGHT TO
MODERATE
YES
NO
o
2025 NEW YORK STATE RESIDENTIAL CODE
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
JOINT DESCRIPTION
TABLE 3.1 NAILING SCHEDULE
WOOD FRAME CONSTRUCTION MANUAL
NUMBER OF
COMMON NAILS
NAIL SPACING
ROOF FRAMING
3-8d
PER RAFTER
CEILING JOIST TO TOP PLATE (TOE-NAILED)
PER JOIST
CEILING JOIST TO PARALLEL RAFTER (FACE NAILED)
EACH LAP
CEILING JOIST LAPS OVER PARTITION (FACE-NAILED)
EACH LAP
COLLAR TIE TO RAFTER (FACE-NAILED)
PER TIE
BLOCKING TO RAFTER (TOE-NAILED)
2-8D
EACH END
RIM BOARD TO RAFTER (END-NAILED)
2-16D
EACH END
WALL FRAMING
TOP PLATE TO TOP PLATE (FACE-NAILED)
2-16D
PER FOOT
TOP PLATES AT INTERSECTIONS (FACE-NAILED)
4-16D
JOINTS EACH SIDE
STUD TO STUD (FACE-NAILED)
2-16D
24" O.C.
HEADER TO HEADER (FACE-NAILED)
16D
16" O.C. ALONG EDGES
TOP OR BOTTOM PLATE TO STUD (END-NAILED)
2-16D
PER 2"x4" STUD
2-16D
PER FOOT
1,2
FLOOR FRAMING
JOIST TO SILL, TOP PLATE, OR GIRDER (TOE-NAILED)
4-8D
PER JOIST
BRIDGING TO JOIST (TOE-NAILED)
2-8D
EACH END
BLOCKING TO JOIST (TOE-NAILED)
2-8D
EACH END
BLOCKING TO SILL OR TOP PLATE (TOE-NAILED)
3-16D
EACH BLOCK
LEDGER STRIP TO BEAM (FACE-NAILED)
3-16D
EACH JOIST
JOIST ON LEDGER TO BEAM (TOE-NAILED)
3-8D
PER JOIST
BAND JOIST TO JOIST (END-NAILED)
3-16D
PER JOIST
BAND JOIST TO SILL, OR TOP PLATE (TOE-NAILED)
2-16D
PER FOOT
ROOF FRAMING
STRUCTURAL PANELS
8D
DIAGONAL BOARD SHEATHING
2-8D
PER SUPPORT
1"X6" OR 1"X8"
3-8D
PER SUPPORT
1"X10" OR WIDER
CEILING SHEATHING
GYPSUM WALL BOARD
5D COOLERS
7" EDGE / 10" FIELD
WALL SHEATHING
STRUCTURAL PANELS
8D
FIBERBOARD PANELS
6D
3" EDGE / 6" FIELD
7/16"
25/32"
8D3
3" EDGE / 6" FIELD
GYPSUM WALL BOARD
5D COOLERS
7" EDGE / 10" FIELD
HARDBOARD
PARTICLE PANELS
DIAGONAL BOARD SHEATHING
PER SUPPORT
1"X6" OR 1"X8"
PER SUPPORT
1"X10" OR WIDER
FLOOR SHEATHING
2-8D
3-8D
STRUCTURAL PANELS
1" OR LESS
GREATER THAN 1"
8D
10D
6" EDGE / 12" FIELD
6" EDGE / 6" FIELD
DIAGONAL BOARD SHEATHING
PER SUPPORT
1"X6" OR 1"X8"
PER SUPPORT
1"X10" OR WIDER
2-8D
3-8D
3-16D
PER 2"x6" STUD
4-16D
PER 2"x8" STUD
3-8d
3-16d
3-16d
3-8d
6" EDGE / 12" FIELD
6" EDGE / 12" FIELD
2-8D
2-8D
PER SUPPORT
PER SUPPORT
FASTEST MILE WINDSPEED (MPH)
ROOF SPAN (FT.)
-
TABLE 3.4 RIDGE TENSION STRAP CONNECTION REQUIREMENTS
ROOF PITCH
ROOF SPAN (FT.)
FASTEST MILE WINDSPEED (MPH)
FASTEST MILE WINDSPEED (MPH)
6:12
7:12 - 12:12
RAFTER
RIDGE TENSION
STRAP
RIDGE BEAM
-
4:12
5:12
NAILING REQUIREMENTS
FRAMING
SPACING (IN.)
RAFTER TO TOP PLATE (TOE-NAILED)
BOTTOM PLATE TO FLOOR JOIST, BANDJOIST, ENDJOIST
OR BLOCKING (FACE-NAILED)
NUMBER OF 8d COMMON NAILS IN EACH END
OF 1-1/4" x 20 GAGE STRIP
TABLE 3.4B UPLIFT STRAP CONNECTION REQUIREMENTS
(ROOF-TO-WALL, WALL-TO-WALL, AND WALL-TO-FOUNDATION)
# OF 8d COMMON NAILS IN EACH
END OF 1-1/4" 20 GAGE STRAP
REQUIRED CAPACITY OF
RIDGE CONNECTION (PLF)
DESIGN LOADS:
LIVE DEAD
DECKS / PORCHES
ROOMS OTHER THAN SLEEPING ROOMS
ATTICS WITHOUT STORAGE
ATTICS WITH STORAGE
SLEEPING ROOMS
SNOW LOAD:
PER :12 PITCH
ROOF :
HEADER SCHEDULE
POSTS SHALL BE 4X4 (NOMINAL)
*
(2) 2X12 8'-0" TO 10'-0"
(2) 2X10 6'-0" TO 7'-11"
NOMINAL LUMBER SIZE: SPANS:
(2) 2X6 UP TO 3'-11"
(2) 2X8 4'-0" TO 5'-11"
ALL WOOD FRAMING INCLUDING JOISTS,
BEAMS, POSTS, STUDS, ETC. TO BE
DOUG. FIR-LARCH #2 OR BETTER,
MODULOUS OF ELASTICITY "E" 1,600,000
WITH A MIN. Fb=1400 psi (2x4),
Fb=1200 psi (2x6), Fb=1100 psi (2x8),
Fb=1000 psi (2x10), Fb=900 psi (2x12).
NOTE: ALL SIZES CALLED OUT ON ANY OF THE
FOLLOWING DRAWINGS WILL SUPERCEDE THIS
SCHEDULE.
NOTE: ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE
REQUIREMENTS OF
AND THE FOLLOWING:
CODE COMPLIANCE:
THESE PLANS HAVE BEEN PREPARED UNDER THE 2020 RESIDENTIAL
CODE OF NEW YORK STATE. ALL DETAILS AND INFORMATION HEREIN
IS CERTIFIED BY THE LISTED DESIGN PROFESSIONAL AND IN
COMPLIANCE WITH THE FOLLOWING:
1.
2020 INTERNATIONAL RESIDENTIAL CODE FOR ONE AND TWO
FAMILY HOUSES
2.
2020 NYS UNIFORM CODE SUPPLEMENT
3.
2020 IECC
4.
ENGINEERED STRUCTURAL COMPONENTS PER ASCE 7-10
5.
WOOD FRAME CONSTRUCTION MANUAL 2018 EDITION FOR ONE
AND TWO STORY FAMILY DWELLINGS
THERE SHALL BE NO DEVIATION IN CONSTRUCTION PRACTICE FROM
THE REQUIREMENTS OF THESE DOCUMENTS.
MATERIALS SHOWN AND SPECIFIED ON THESE PLANS HAVE BEEN
CHOSEN BASED ON PERFORMANCE DATA AND MANUFACTURERS
RECOMMENDATIONS. AND SUBSTITUTIONS WILL BECOME THE
BURDEN AND REASONABILITY OF THE CONTRACTOR TO VALIDATE
THE COMPLIANCE WITH CODES AND TESTING PROCEDURES,
INCLUDING THE PRODUCTION OF ANSI TEST RESULTS , AAMA TEST
RESULTS, ETC.
THIS APPLICATION/ PROJECT WILL CONFORM TO THE 2020
RESIDENTIAL CODE OF NEW YORK STATE
ENGINEERED STRUCTURAL COMPONENTS AS PER ASCE 7-10
TOWN OF CROTON ON HUDSON
D13
PC, EPC Post Caps
D08
ABA, ABU Post Bases
D04
LUC, HUC Joist Hangers
D01
General Notes
D14
CCQ, ECCQ Post Caps
D09
PBS Post Bases
D05
SUR/SUL 45° Skewed Joist Hangers
D15
CC, ECC Post Caps
D10
CBSQ Post Bases
D06
LS Framing Angles
D02
Fasteners
D16
H Hurricane Ties
D11
BC, BCS Post Caps
D07
LSU, LSSU Adjustable Joist Hangers
D12
AC, LPC, LCE Post Caps
D03
LUS Joist Hangers
General Notes:
1. Outdoor environments are generally more corrosive to steel. If you choose to use ZMAX® or HDG finish or stainless steel material on an outdoor project, you should periodically inspect your connectors
and fasteners or have a professional inspection performed. Regular maintenance, including water-proofing of the wood used in your outdoor project is also a good practice.
2. Coatings Available:
2.1.
ZMAX: Galvanized (G185) 1.85 oz. of zinc per square foot of surface area. (hot-dip galvanized per ASTM A653 total both sides). These products require hot-dip galvanized fasteners (fasteners
which meet the specifications of ASTM A153).
2.2.
HDG - Hot Dip Galvanized: Products are hot-dip galvanized after fabrication (14 ga. and thicker). The coating weight increases with material thickness. The minimum specified coating weight is 2.0
oz. per square foot. (per ASTM A123 total both sides). These products require hot-dip galvanized fasteners (fasteners which meet the specifications of ASTM A153).
2.3.
SS - Stainless Steel: Connectors are manufactured from Type 316L stainless steel, and provide greater durability against corrosion. Stainless-steel nails are required with stainless-steel products,
and are available from Simpson Strong-Tie.
3. When using stainless steel connectors, use stainless steel fasteners. When applications allow the use of ZMAX/HDG galvanized connectors, use HDG fasteners that meet the specifications of ASTM
A153 or equivalent coating offered on Simpson Strong-Tie fasteners.
4. Due to many variables involved with outdoor construction, Simpson Strong-Tie cannot provide estimates on service life of connectors, anchors or fasteners.
5. To obtain optimal performance from Simpson Strong-Tie products, the products must be installed properly and used in accordance with the installation instructions and design limits provided by Simpson
Strong-Tie.
6. All installation notes and guidelines within the current Wood Construction Connectors catalog shall apply for the connectors, anchors, and fasteners shown.
7. Simpson Strong-Tie reserves the right to change the specifications, design and models shown without notice or liability for such changes.
8. Simpson Strong-Tie does not guarantee the performance or safety of products that are modified, improperly installed or not used in accordance with the design.
9. All references to bolts or machine bolts (MB) are structural quality through bolts (not lag screws or carriage bolts) equal to or better than ASTM A307, grade A. Bolt holes shall be at least a minimum 1/32"
and no more than a maximum of 1/16" larger than the bolt diameter per 2005 NDS Section 11.1.2.
10.Unless noted otherwise, all references to standard cut washers refer to Type A plain washers (W) conforming to the dimensions shown in ASME B18.22.1 for the appropriate rod sizes.
11.Unless stated otherwise, Simpson Strong-Tie cannot and does not make any representation regarding the suitability of use or load-carrying capacities of connectors installed with improper fasteners.
0.162"
0.148"
0.162"
0.161"
0.131"
0.131"
0.161"
0.148"
0.131"
0.131"
0.25"
16d
Common
10d
Common
SD Screw
#10x2½
16dx2½
SD Screw
#9x2½
8d
Common
SD Screw
#10x1½
10dx1½
SD Screw
#9x1½
8dx1½
SDS Screw
¼" x various
lengths
3½
2½
1½
Fastener Notes:
1. The specified quantity, type and size of fastener must be installed in the correct holes on the connector to achieve published loads.
Incorrect fastener selection or installation can compromise connector performance and could lead to failure.
2. Nail diameter assumes no coating. See technical bulletin T-NAILGUIDE for more information.
3. The Simpson Strong-Drive® SD structural-connector screw is the only screw approved for use with our connectors.
4. NAIL reference in tables: 16d = 16d common, 10d = 10d common
Fastening Identification
Round Holes
Purpose: to fasten a
connector.
Fill requirements:
always fill, unless noted
otherwise.
Obound Holes
Purpose: to make
fastening a connector in a
tight location easier.
Fill requirements:
always fill.
Hexagonal Holes
Purpose: to fasten a
connector to concrete
or masonry.
Fill requirements:
always fill when
fastening a connector
to concrete or masonry.
Triangular Holes
Purpose: to increase a
connector's strength or to
achieve Max strength.
Fill requirements: when
the designer specifies
Max nailing.
Diamond Holes
Purpose: to temporarily fasten
a connector to make installing
easier.
Fill requirements: none.
Speed Prongs
Used to temporarily
position and secure the
connector for easier and
faster installation.
Dome Nailing
This feature guides the
nail into the joist and
header at a 45° angle.
Double Shear Nailing
The nail is installed in the joist
and header, distributing the load
through two points on each joist
nail for greater strength.
Pilot Holes
Tooling holes for
manufacturing
purposes. No
fasteners required.
LUS
Typical LUS28Z
Installation
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· LUS hangers install with double shear nailing.
· For installations into single 2x headers or
ledgers, use the specified full length fasteners
into the joist and the following fasteners into
the header for reduced loads in accordance
with www.strongtie.com:
··
10dx1½ nails for installations with Nails
··
SD #9x1½ for LUS28Z and LUS210Z
installations with SD Screws
··
SD #10x1½ for LUS26-2Z and
LUS210-2Z installations with SD Screws
Model No.
Dimensions (in.)
Fasteners
Nails
SD Screws
W
H
B
Header
Joist
Header
Joist
LUS26Z
1 9/16
4 3/4
1 3/4
4-10d
4-10d
-
-
LUS28Z
1 9/16
6 5/8
1 3/4
6-10d
4-10d
6-SD #9x2½
4-SD #9x2½
LUS210Z
1 9/16
7 13/16
1 3/4
8-10d
4-10d
8-SD #9x2½
4-SD #9x2½
LUS26-2Z
3 1/8
4 7/8
4-16d
4-16d
4-SD #10x2½
4-SD #10x2½
LUS210-2Z
3 1/8
8-16d
6-16d
8-SD #10x2½
6-SD #10x2½
LUC
Typical HUC Installation
(LUC Similar)
Model No.
Dimensions (in.)
Fasteners
Nails
SD Screws
W
H
B
Header
Joist
Header
Joist
LUC26Z
1 9/16
4 3/4
1 3/4
6-10d
4-10dx1½
6-SD #9x2½
4-SD #9x1½
LUC210Z
1 9/16
7 3/4
1 3/4
10-10d
6-10dx1½
10-SD #9x2½
6-SD #9x1½
HUC26-2Z
3 1/8
5 3/8
2 1/2
12-16d
6-10d
-
-
HUC28-2Z
3 1/8
2 1/2
14-16d
6-10d
-
-
HUC210-2Z
3 1/8
8 13/16 2 1/2
18-16d
10-10d
-
-
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· For HUC installations, models have triangle and
round holes. To achieve maximum loads, fill both
round and triangle holes (fastener quantities listed fill
both holes).
· For installations into single 2x headers or ledgers,
use the specified full length fasteners into the joist
and the following fasteners into the header for
reduced loads in accordance with
www.strongtie.com:
··
10dx1½ nails for installations with Nails
··
SD #9x1½ for LUC26Z and LUC210Z
installations with SD Screws
SUL Skewed
Left Hanger
(SUR is Skewed
Right)
Typical SUR
Installation
Model No.
Joist Size
Dimensions (in.)
Fasteners
W
H
B
A1
A2
Header
Joist
SUR/L26Z
2x6, 8
1 9/16
1 1/8
1 5/16
6-16d
6-10dx1½
SUR/L210Z
2x10, 12
1 9/16
8 1/8
1 1/8
1 5/16
10-16d
10-10dx1½
SUR/L210-2Z
(2) 2x10, 12
3 1/8
8 11/16
2 5/8
1 7/16
2 3/8
14-16d
6-16dx2½
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· The joist may be square cut
or bevel cut.
· These hangers will normally
accommodate a 40° to 50°
skew.
LS
Typical
LS50Z
Installation
LS Top View
Model No.
L (in)
Fasteners
LS30Z
3 3/8
6-10d
LS50Z
4 7/8
8-10d
LS70Z
6 3/8
10-10d
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· Field skewable; bend one time only.
· Joist must be constrained against rotation
(for example, with solid blocking) when
using a single LS per connection.
STEP 1
Nail hanger to slope-cut carried
member, installing seat nail first.
No bevel necessary for skewed
installation. Install joist nails at 45
° angle.
STEP 2
Skew flange from 0-45 °. Bend
other flange back along
centerline of slots until it meets
the header. Bend one time only.
STEP 3
Attach hanger to the carrying
member, acute angle side first
(see footnote 1). Install nails at an
angle.
Model No.
Dimensions (in.)
Fasteners
W
H
A
Header
Joist
LSU26Z
1 9/16
4 7/8
1 1/2
6-10d
5-10dx1 1/2
LSSU210Z
1 9/16
8 1/2
1 5/8
10-10d
7-10dx1 1/2
1. For skewed LSSU, the inner most face fasteners on the acute angle side are not
installed.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· Follow 3-step installation sequence for skewed
or sloped/skewed applications.
· Do not substitute 10dx1½ nails for face nails.
· To see an installation video on this product,
visit www.strongtie.com
LSSU210Z
Slope to
45 ° up or down.
"A" Flanges
ABA44Z
ABU44Z
Typical ABA Installation
(ABU Similar)
Model
No.
Post
Size
Dimensions (in.)
Anchor
Dia.
Post Fasteners
W
L
H
HB
Nails
SD Screws
Machine Bolts
Qty.
Dia.
ABA44Z
4x4
3 9/16
3 1/8
3 1/16
-
1/2
6-10d
6-SD #9x1½
-
-
ABU44Z
4x4
3 9/16
5 1/2
1 3/4
5/8
12-16d
12-SD #10x1½
1/2
ABA46Z
4x6
3 9/16
5 3/16
3 1/8
-
5/8
8-16d
8-SD #10x1½
-
-
ABU46Z
4x6
3 9/16
2 5/8
5/8
12-16d
-
1/2
ABA66Z
6x6
5 1/2
5 1/4
3 1/8
-
5/8
8-16d
8-SD #10x1½
-
-
ABU66Z
6x6
5 1/2
6 1/16
1 3/4
5/8
12-16d
-
1/2
ABU88Z
8x8
7 1/2
-
2 - 5/8
18-16d
-
-
-
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· ABA, ABU - for pre-pour installed
anchors. For Simpson Strong-Tie epoxy
or mechanical anchors, select and install
in accordance with www.strongtie.com.
· Products require washers between the
nut and the base. Washers are supplied
with the ABU but not the ABA, which
requires a standard cut washer.
Model No.
Dimensions (in.)
Post Fasteners
W
L
H
HB
Nails
SD Screws
Machine Bolts
Qty.
Dia.
PBS44AHDG
3 9/16
3 1/2
6 1/4
3 7/16
14-16d
14-SD #10x1½
1/2
PBS66HDG
5 1/2
5 3/8
6 1/2
3 11/16
14-16d
-
1/2
1. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· Embed into wet concrete up
to the bottom of the 1"
standoff base plate. A 2"
minimum side cover is
required to obtain the full
load. Holes in the bottom of
the straps allow for free
concrete flow.
· Allow concrete to cure
before installation of the
post.
Typical PBS
Typical
CBSQ44
Installation
3" Min.
Sidecover
1. indicates connector is available in stainless steel. Replace -SDS2HDG in model
number with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Model No.
Post
Size
Dimensions (in.)
Number of
SDS Screws
W1
W2
D
H
CBSQ44-SDS2HDG
4x4
3 9/16
3 1/2
7 1/8
8 3/8
14-SDS ¼"x2"
CBSQ46-SDS2HDG
4x6
3 9/16
5 5/16
7 13/16
8 11/16
14-SDS ¼"x2"
CBSQ66-SDS2HDG
6x6
5 1/2
5 1/2
6 7/8
8 3/4
14-SDS ¼"x2"
CBSQ86-SDS2HDG
6x8
7 1/2
5 3/8
6 1/8
8 11/16
12-SDS ¼"x2"
CBSQ88-SDS2HDG
8x8
7 1/2
7 3/8
6 1/8
8 11/16
12-SDS ¼"x2"
Installation:
· Install Simpson Strong-Tie SDS
14" x 2" wood screws, which are
provided with the column base,
with a 3 8" hex head driver. (Lag
screws will not achieve the same
load.)
· Allow concrete to cure before
installation of the post.
· For full loads, a minimum of 3"
side cover shall be provided.
Typical CBSQ
Typical BCS
Installation (BC
Similar)
BCS
(BC Similar)
Model No.
Dimensions (in.)
Fasteners
W1
W2
L1
L2
H1
H2
Nails
SD Screws
Beam
Flange
Post
Flange
Beam Flange
Post Flange
BC4Z
3 9/16
3 9/16
2 7/8
2 7/8
6-16d
6-16d
6-SD #10x1½
6-SD #10x1½
BC6Z
5 1/2
5 1/2
4 3/8
4 3/8
3 3/8
3 3/8
12-16d
12-16d
-
-
BCS2-2/4Z
3 1/8
3 9/16
2 7/8
2 7/8
2 15/16
2 15/16
8-10d
6-10d
8-SD #9x2½
6-SD #9x2½
BCS2-3/6Z
4 5/8
5 9/16
4 3/8
2 7/8
3 5/16
2 15/16
12-16d
6-16d
-
-
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· BCS: Install dome nails on
beam; drive nails at an
angle through the beam
into the post below.
· BC: Do not install bolts into
pilot holes.
Typical
LCE4Z
Installation
LPCZ
AC
Model No.
Dimensions (in.)
Fasteners
W
L
Nails
SD Screws
Beam
Post
Beam
Post
AC4Z
3 9/16
6 1/2
14-16d
14-16d
14-SD #10x1½
14-SD #10x1½
AC6Z
5 1/2
8 1/2
14-16d
14-16d
14-SD #10x1½
14-SD #10x1½
LPC4Z
3 9/16
3 1/2
8-10d
8-10d
8-SD #9x1½
8-SD #9x1½
LPC6Z
5 9/16
5 1/2
8-10d
8-10d
-
-
LCE4Z
-
5 3/8
14-16d
10-16d
14-SD #10x1½
10-SD #10x1½
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· Install in pairs.
· For LCE4Z installations on
mitered corner conditions,
refer to www.strongtie.com
for more information.
PC
Typical
EPC
Installation
Model
No.
Post
Size
Dimensions (in.)
Fasteners
W1
W2
L1
L2
L3
Nails
SD Screws
Post
Beam
Post
Beam
PC
EPC
PC
EPC
PC44-16Z
4x4
3 9/16
3 9/16
2 5/8
7 5/16
8-16d
12-16d
8-16d
8-SD
#10x1½
12-SD
#10x1½
8-SD
#10x1½
PC46-16Z
4x6
3 9/16
5 1/2
2 5/8
9 1/4
8-16d
12-16d
8-16d
-
-
-
PC66-16Z
6x6
5 1/2
5 1/2
4 9/16
9 1/4
8-16d
12-16d
8-16d
-
-
-
1. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· For end condition,
specify EPC
· Use all specified
fasteners.
· Do not install bolts
into pilot holes.
CCQ
ECCQ
Typical CCQ
Installation
Model No.
Beam
Width
Dimensions (in.)
No. of SDS ¼"x
2½" Screws
W1
W2
L1
H
CCQ
ECCQ
Beam
Post
CCQ3-6HDG
3 1/8
3 1/4
5 1/2
8 1/2
CCQ44HDG
4x
3 5/8
3 5/8
8 1/2
CCQ46HDG
4x
3 5/8
5 1/2
8 1/2
CCQ48HDG
4x
3 5/8
7 1/2
8 1/2
CCQ66HDG
6x
5 1/2
5 1/2
8 1/2
CCQ68HDG
6x
5 1/2
7 1/2
8 1/2
1. indicates connector is available in stainless steel. Replace HDG in model
number with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· For end conditions, specify ECCQ
· Install Simpson Strong-Tie SDS 14" x
212" screws, which are provided with
the column cap, with a 3 8" hex head
driver. SDS screws install best with a
low speed 12" drill.
· Beam depth must be a minimum 7".
CC
ECC
Typical CC
Installation
Model No.
Beam
Width
Dimensions (in.)
Machine Bolts
W1
W2
L
H1
Dia.
Beam
Post
CC
ECC
CC
ECC
CC3-1/4-4HDG
3 1/8
3 1/4
3 5/8
7 1/2
6 1/2
5/8
CC3-1/4-6HDG
3 1/8
3 1/4
5 1/2
7 1/2
6 1/2
5/8
CC44HDG
4x
3 5/8
3 5/8
5 1/2
5/8
CC66HDG
6x
5 1/2
5 1/2
7 1/2
6 1/2
5/8
1. indicates connector is available in stainless steel. Replace HDG in model
number with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
Installation:
· For end conditions, specify ECC
· Bolt holes shall be a minimum 132" to a maximum 116" larger than the bolt diameter.
· Contact engineered wood manufacturers for connections that are not through the
wide face.
· Beam depth must be at least as tall as H1.
Typical H1Z
and H2.5Z
Installation
H1Z
H2.5Z
Model
No.
Fasteners
Nails
SD Screws
To Joist
To Beam
To Joist
To Beam
H1Z
6-8dx1½
4-8dx1½
6-SD #9x1½
4-SD #9x1½
H2.5Z
5-8dx1½
5-8dx1½
5-SD #9x1½
5-SD #9x1½
H8Z
5-10dx1½
5-10dx1½
5-SD #9x1½
5-SD #9x1½
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
H8Z
Installation:
· Use all specified fasteners.
H1Z
H2.5Z
TA10Z
Inverted
Installation
Model
No.
Fasteners
Stringer
Tread
TA9Z
3-SDS ¼"x1½"
2-SDS ¼"x1½"
TA10Z
3-SDS ¼"x1½"
4-SDS ¼"x1½"
TA10Z
4-SDS ¼"x1½"
3-SDS ¼"x1½"
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to current Wood Construction Connectors catalog for additional information.
TA9Z
(TA10Z length =
10 1/4")
Installation:
· Use all specified fasteners.
· For double 2x6 treads, install
TA10Z inverted with 4
screws installed into the
treads.
SDS Ledger Installation
1½" minimum from top of ledger and band joist
4" to 5"
from end of
ledger
On-center spacing
of SDS wood screws
per designer
3" minimum
row spacing
1½" minimum from
bottom of ledger
and band joist
Size (in.)
Model No.
Thread Length
(in.)
¼" x 3½"
SDS25312
2¼
¼" x 5"
SDS25500
2¾
1. indicates connector is available in stainless steel. Add SS to
model number when ordering.
2. Refer to current F-SDSLDGR for spacing and additional information.
3. The screws shall be staggered from the top to the bottom along the
horizontal run of the deck ledger per IRC 2009 Section R502.2.2.1.1.
SDS
Screw
Installation:
· Install Simpson Strong-Tie
SDS wood screws with a 3 8"
hex head driver.
· SDS screws install best with a
low speed 12" drill.
S3.5
DTT2Z
Model No.
CL
Anchor
Dia.
Fasteners
DTT2Z
13/16
1/2"
8-SDS ¼"x1½"
1. indicates connector is available in stainless steel. Replace Z in model number
with SS when ordering.
2. Refer to T-GRDRLPST and T-DECKLATLOAD for additional information.
Installation:
· Install Simpson Strong-Tie SDS wood screws
with a 3 8" hex head driver. SDS screws install
best with a low speed high torque drill.
· A standard cut washer (provided) must be
installed between the nut and the DTT2Z seat.
· Bolt holes shall be a minimum 132" to a maximum
116" larger than the bolt diameter.
DTT2Z Installed as a Lateral Connector for a Deck
Guardrail Post.
For more information on guardrail post connections,
and installation instructions, see technical bulletin
T-GRDRLPST (available at www.strongtie.com).
DTT2Z Installed as a Lateral Connector for a
Deck-to-House Lateral Load Connection
For more information on this connection, and
installation instructions, see technical bulletin
T-DECKLATLOAD (available at www.strongtie.com).
LSCZ Typical
Installation
Deck Framing
Stair Stringer
Model
No.
Fasteners
Nails
SD Screws
Rim Joist
Stringer
Wide Face
Stringer
Narrow Face
Rim Joist
Stringer
Wide Face
Stringer
Narrow Face
LSCZ
8-10dx1½
8-10dx1½
1-10dx1½
8-SD #9x1½
8-SD #9x1½
1-SD #9x1½
LSCZ
Installation:
· Before fastening, position the stair stringer with the LSCZ on the carrying member to verify where the bend
should be located.
· Tabs on the LSCZ must be positioned to the inside of the stairs.
· The fastener that is installed into the bottom edge of the stringer must go into the second-to-last hole.
· A minimum distance of 3 4" measured from the lowest rim-joist fastener to the edge of rim joist is required.
1. indicates connector is available in stainless steel. Replace Z in model number with SS when ordering. Stainless steel
models must be fastened with nails.
2. Refer to current Wood Construction Connectors catalog for additional information.
SIMPSON STRONG-TIE COMPANY INC.
NORTHEAST: 2600 International Street, Columbus, Ohio 43228
NORTHWEST: 5151 South Airport Way, Stockton, California 94588
SOUTHEAST: 2221 Country Lane, McKinney, Texas 75069
SOUTHWEST: 12246 Holly Street, Riverside, California 92509
-REFERENCE NOTES
-NAILING SCHEDULE
-CLIMATE&GEOGRAPHY DESIGN CRITERIA
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
H2.5
Simpson Strong-Tie
Simpson Strong-Tie
H2
2020.
8.1.2.1)
32"
8"
16"
3"
2"
2"
3"
3.4
4"
2"
2"
3.4
15"
7"
14)
4"
12"
3.4
4" 20
3.4
4"
36"
8"
.15"
3" 3"
3.2.1.7.
4"
30#
3.4
3.4
3.2.1.7.
3.4
8"
3.3
12"
4"
3.4
3.2.2.2
3.3
44)
2"
7"
15"
/
12"
8"
12"
4"
3.2
4"
3.4
4"
12"
26 2" 6"
28 - 2"x8",2"x10",2"x12"
LUS26,LUS28/LUS26-2,LUS210,LUS210-2
10"
-DETAIL CONNECTION NOTES
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
3"
CONTINUOUS BEAD
OF SEALANT
CONTINUOUS BEAD
CONTINUOUS BEAD
WINDOW PERIMETER
CONTINUOUS MINIMAL
EXPANDING FOAM AT
CEILING GYPSUM BOARD
EXPANDING FOAM AT
CONTINUOUS MINIMAL
WINDOW PERIMETER
CONTINUOUS BEAD
CONTINUOUS BEAD
CONTINUOUS BEAD
OF SEALANT
OF SEALANT
AS AIR BARRIER
WINDOW UNIT AS
AIR BARRIER
OF ADHESIVE
OF SEALANT
OF SEALANT
1" RIGID INSULATION AS ATTIC EAVE BAFFLE CUT
AROUND MANUFACTURED VENT
AIR BARRIER AT GARAGE BAND JOIST 1" RIGID
INSULATION w/ 1"x3" WOOD FURRING
AIR BARRIER AT GARAGE BAND JOIST 1" RIGID
INSULATION w/ 2"x2" WOOD FURRING
AIR BARRIER AT GARAGE BAND JOIST 1.5" RIGID
INSULATION w/ 2"x4" SLEEPERS
AIR SEAL AT BUILT-OUT SOFFIT
AIR SEAL AT CABINET SOFFIT - SINGLE STORY
AIR SEAL AT CABINET SOFFIT - TWO STORY
AIR SEAL AT CHASE WALLS - PLAN VIEW
AIR SEAL AT DUCT BOOT
AIR SEAL AT DUCT SOFFIT
AIR SEAL AT TOP PLATE ELECTRICAL PENETRATION
AIR SEAL AT TOP PLATE PIPE PENETRATION
AIR SEALING AT ATTIC HATCH - FINISH SCREWS
AIR SEALING AT ATTIC PULL DOWN ATTIC STAIR
AIR SEALING AT CANTILEVERED MANUFACTURED
FIREPLACE ASSEMBLY
AIR SEALING AT COMMON WALL BETWEEN DWELLING
UNITS
AIR SEALING AT CORNER VERTICAL BATHTUB CHASE
AIR SEALING AT CORNER VERTICAL CHASE
AIR SEALING AT DOUBLE WALLS
AIR SEALING AT INTERIOR WALL BETWEEN
CONDITIONED SPACE & UNCONDITIONED CELLAR
AIR SEALING AT PLATFORM FOR MANUFACTURED
FIREPLACE ASSEMBLY
AIR SEALING AT PORCH ROOF AT .5" PLYWOOD
EXTERIOR SHEATHING
AIR SEALING AT PORCH ROOF AT 1" RIGID INSULATION
SHEATHING
AIR SEALING AT RECESSED LIGHTING IN ATTIC
AIR SEALING AT RECESSED LIGHTING IN ATTIC
AIR SEALING AT SKYLIGHT SHAFT
AIR SEALING AT WHOLE HOUSE FAN ENCLOSURE
AIR SEALING BEHIND SHOWER w/ CAVITY RIGID INSULATION
AIR SEALING BEHIND TUB w/ CAVITY RIGID INSULATION
AIR SEALING BEHIND TUB w/ THIN-PROFILE SHEATHING -
SECTION VIEW
CONCEPTUAL AIR SEALING STRATEGY AT UPPER FLOOR
BAND JOIST
CONCEPTUAL INSULATION PRACTICE AT ATTIC-STYLE TRUSS SYSTEM ABOVE CONDITIONED SPACE
CONCEPTUAL INSULATION PRACTICE AT ATTIC-STYLE TRUSS SYSTEM ABOVE UNCONDITIONED SPACE
TURNED DOWN CONCRETE SLAB .75" RIGID INSULATION
TURNED DOWN CONCRETE SLAB 1" RIGID INSULATION
AIR BARRIER AT GARAGE BAND JOIST 1" RIGID
CONCEPTUAL AIR SEALING STRATEGY - UPPER WALL SECTION
INSULATION w/ 2"x2" WOOD FURRING
1" EXTERIOR INSULATION SHEATHING AS ATTIC EAVE
BAFFLE AND VENT
AIR SEALING BEHIND SHOWER w/ THIN-PROFILE
SHEATHING
THIN-PROFILE ATTIC EAVE BAFFLE AND VENT
CONCEPTUAL INSULATION AT CAPE-STYLE ROOF -
CEILING & KNEE WALL CAVITY INSULATION
CONCEPTUAL INSULATION AT CAPE-STYLE ROOF - ROOF
CAVITY INSULATION w/ RIGID INSULATION CLOSURE
CONTINUOUS BEAD
CONTINUOUS SILL SEALER
- FULL WIDTH OF MUDSILL
FOUNDATION WALL AS
CONCRETE SLAB AS
CONTINUOUS BEAD
CONTINUOUS BEAD
CONTINUOUS BEAD
CONTINUOUS MINIMAL
EXPANDING FOAM AT
WINDOW PERIMETER
EXPANDING FOAM AT
CONTINUOUS MINIMAL
WINDOW PERIMETER
CONTINUOUS BEAD
CONTINUOUS BEAD
OF SEALANT
AIR BARRIER
AIR BARRIER
OF SEALANT
OF SEALANT
OF SEALANT
OF ADHESIVE
OF SEALANT
WINDOW UNIT AS
AIR BARRIER
CONCEPTUAL AIR SEALING STRATEGY - LOWER WALL
SECTION
INSTALL 1" RIGID INSULATION CUT TO
FIT BETWEEN THE RAFTERS. FOAM
SEAL BOTH SIDES ALONG RAFTER
WITH EXPANDING FOAM SEALANT.
MAINTAIN EQUAL VENT SPACE FOR
LENGTH OF RIGID INSULATION
VENTED AIRSPACE
ATTIC INSULATION
INSTALL 1" RIGID INSULATION
VERTICALLY TO CONNECT
INSULATING SHEATHING TO
RIGID INSULATION BAFFLE.
FOAM SEAL BOTH JOINTS.
CONTINUOUS BEAD OF SEALANT
EXTERIOR INSULATED WALL
2" RIGID INSULATION
CONTINUOUS BEAD OF SEALANT
EXTERIOR INSULATED WALL
2" RIGID INSULATION
1" RIGID INSULATION ROUGH
CUT AROUND VENTILATION
CHUTE - AIR SEAL PERIMETER
w/ EXPANDING FOAM SEALANT
VENTILATION CHUTE
ATTIC INSULATION
INTERIOR CONDITION
SPACE
CAVITY INSULATION
CONTINUOUS BEAD OF SEALANT
INTERIOR CONDITIONED
SPACE
INSULATED DEMISING WALL
GARAGE
(UNCONDITIONED
SPACE)
ROOM ABOVE
GARAGE
WOOD FLOOR
TRUSS ASSEMBLY
1" RIGID INSULATION
1"x3" SLEEPERS 16" OC
INTERIOR CONDITION
SPACE
CAVITY INSULATION
CONTINUOUS BEAD OF SEALANT
INTERIOR CONDITIONED
SPACE
INSULATED DEMISING WALL
GARAGE
(UNCONDITIONED
SPACE)
ROOM ABOVE
GARAGE
WOOD FLOOR
TRUSS ASSEMBLY
1" RIGID INSULATION
2"x2" SLEEPERS 16" OC
INTERIOR CONDITION
SPACE
CAVITY INSULATION
CONTINUOUS BEAD OF SEALANT
INTERIOR CONDITIONED
SPACE
INSULATED DEMISING WALL
GARAGE
(UNCONDITIONED
SPACE)
ROOM ABOVE
GARAGE
WOOD FLOOR
TRUSS ASSEMBLY
1" RIGID INSULATION
2"x4" SLEEPERS 16" OC
WOOD FRAME
FLOOR ASSEMBLY
CONTINUOUS BEAD
OF SEALANT
WOOD FRAME
SOFFIT ASSEMBLY
PROVIDED INTERIOR
SHEATHING AT
EXTERIOR WALL PRIOR
TO SOFFIT ASSEMBLY
CONTINUOUS BEAD OF
SEALANT
CONTINUOUS BEAD
OF SEALANT, TYP.
PROVIDE INTERIOR
SHEATHING AT
EXTERIOR WALL &
CEILING PRIOR TO
SOFFIT ASSEMBLY
WOOD FRAME
SOFFIT ASSEMBLY
INTERIOR CABINETRY
WOOD FRAME
FLOOR ASSEMBLY
CONTINUOUS BEAD
OF SEALANT, TYP.
PROVIDE INTERIOR
SHEATHING AT
EXTERIOR WALL
PRIOR TO SOFFIT
ASSEMBLY
WOOD FRAME
SOFFIT ASSEMBLY
INTERIOR CABINETRY
INTERIOR CHASE
WALLS
PIPE PENETRATION
EXPANDING FOAM AT
PERIMETER OF PIPE
THIN-PROFILE
SHEATHING CLOSURE
AT EXTERIOR WALL
CONTINUOUS BEAD
OF SEALANT
LADDER BLOCKING
EXTERIOR INSULATED
WALL
FLOOR GRILLE
FLOOR DUCT BOOT
CONTINUOUS BEAD OF
SEALANT SUBFLOOR
INSULATED FLEXIBLE
DUCT
TIE AT INNER LINER
MASTIC AT INNER LINER
TIE AT OUTER LINER
WOOD FRAME
FLOOR ASSEMBLY
CONTINUOUS BEAD
OF SEALANT, TYP.
HVAC DUCT
WOOD FRAME
SOFFIT ASSEMBLY
PROVIDE INTERIOR
SHEATHING AT EXTERIOR
WALL PRIOR TO SOFFIT
ASSEMBLY
ELECTRICAL WIRE
TOP PLATE
EXPANDING FOAM SEALANT
WALL STUD
PLUMBING PIPE
TOP PLATE
EXPANDING FOAM
SEALANT
WALL STUD
ATTIC INSULATION
WOOD TRUSS FRAMING
SHEATH INTERIOR OF
ATTIC ACCESS TO +1"
OF INSULATION LEVEL
1" RIGID INSULATION
ACCESS PANEL
DRAW ACCESS PANEL
w/ PERIMETER SCREWS
TRIM AS REQUIRED
FINISH CEILING
ATTIC INSULATION
ATTIC FLOOR FRAMING
RIGID INSULATION "R-VALUE/ DEPTH PER
CLIMATE
COMPRESSIBLE WEATHER STRIPPING AT
PERIMETER OF ENCLOSURE
SITE BUILT ATTIC ENCLOSURE -
MECHANICALLY SECURED
MECHANICAL LATCH TO
PRESSURE SEAL AT WEATHER
STRIPPING
MANUFACTURED
PULL DOWN STAIRS
CONTINUOUS BEAD
OF SEALANT
PREFAB FIREPLACE UNIT
INSULATED EXTERIOR
STUD WALL
INSTALL INTERIOR
SHEATHING PRIOR TO
INSTALLATION OF
PREFAB FIREPLACE UNIT
INSTALL SOLID BLOCKING
- EXPANDING FOAM
SEALANT AROUND
PERIMETER OF
BLOCKING - EACH BAY
WOOD FRAME FLOOR
ASSEMBLY
CAVITY INSULATION
CONTINUOUS BEAD OF
SEALANT
1" RIGID INSULATION
SOFFIT CLOSURE
SEALANT TYP.
INSTALL INTERIOR
SHEATHING AT EXTERIOR
WALL PRIOR TO INTERIOR
WALL ASSEMBLY
PARTITION WALL
LADDER BLOCKING AS REQ'D.
INSULATED EXTERIOR WALL
TUB UNIT
INSTALL PLUMBING
AT INTERIOR WALL
INTERIOR WALL
INTERIOR VERTICAL CHASE
PROVIDE INTERIOR
SHEATHING AT EXTERIOR
WALL PRIOR TO INTERIOR
WALL ASSEMBLY
LADDER BLOCKING AS REQ'D.
INSULATED EXTERIOR WALL
INTERIOR VERTICAL CHASE
PROVIDE INTERIOR SHEATHING
AT EXTERIOR WALL PRIOR TO
INTERIOR WALL ASSEMBLY
INTERIOR WALL
LADDER BLOCKING AS REQ'D.
INSULATED EXTERIOR WALL
INSULATED EXTERIOR STUD WALL
BLOCKING AS REQ'D
CONTINUOUS BEAD OF
SEALANT, TYP.
INSTALL INTERIOR SHEATHING
PRIOR TO INSTALLATION OF
FINISH ENCLOSURE
WOOD FRAME FLOOR ASSEMBLY
INTERIOR INSULATED WALL
BETWEEN CONDITIONED
SPACE & ATTIC
ROUGH STRINGER
GYPSUM BOARD (BOTH
SIDES OF WALL)
EXPANDING FOAM
SEALANT, TYP.
2"x4" BLOCKING
SECTION THRU
SECTION THRU WALL
STAIRWAY
PREFAB FIREPLACE UNIT
INSULATED EXTERIOR
STUD WALL
INSTALL INTERIOR
SHEATHING PRIOR TO
INSTALLATION OF PREFAB
FIREPLACE UNIT
CONTINUOUS BEAD OF
SEALANT
WOOD FRAME FLOOR
ASSEMBLY
EXTERIOR INSULATED WALL
PLYWOOD/OSB SHEATHING
PORCH RAFTER
LEDGER AS REQ'D ON
TOP OF WEATHER
BARRIER & SHEATHING
BUILDING PAPER/ WEATHER BARRIER
EXTERIOR INSULATED WALL
RIGID INSULATION SHEATHING
R-VALUE/THICKNESS PER
CLIMATE (TAPE ALL JOINTS)
LEDGER AS REQ'D ON
TOP OF WEATHER
BARRIER & SHEATHING
PORCH RAFTER
ATTIC INSULATION
MANUFACTURED RECESSED
LIGHT ENCLOSURE
ATTIC TRUSS
EXPANDING FOAM SEALANT AT PERIMETER
CONTINUOUS BEAD OF SEALANT
DRYWALL CEILING
RECESSED LIGHTING FIXTURE
3"MIN.3"
ATTIC INSULATION
MANUFACTURED RECESSED
LIGHT ENCLOSURE
ATTIC TRUSS
EXPANDING FOAM SEALANT AT
PERIMETER
CONTINUOUS BEAD OF
SEALANT
DRYWALL CEILING
RECESSED LIGHTING FIXTURE
BLOCKING AS REQ'D
EXPANDING FOAM
SEALANT
ROOF RAFTER
RIGID INSULATION
R-VALUE/THICKNESS
PER CLIMATE
CONTINUOUS BEAD
OF SEALANT
INSTALL SHEATHING
AT ATTIC SIDE OF
SKYLIGHT SHAFT
CAVITY INSULATION
ATTIC INSULATION
SKYLIGHT SHAFT
GYP. BOARD LINER
ROOF SKYLIGHT
ATTIC INSULATION
RIGID INSULATION R-VALUE/
DEPTH PER CLIMATE
COMPRESSIBLE WEATHER
STRIPPING AT PERIMETER OF
ENCLOSURE
SITE BUILT ATTIC ENCLOSURE -
MECHANICALLY SECURED
MECHANICAL LATCH TO
PRESSURE SEAL AT WEATHER
STRIPPING
WHOLE HOUSE FAN
(SEASONAL USE)
INSULATED EXTERIOR STUD WALL
TILE SURROUND FINISH
(2) LAYERS RIGID INSULATION
CEMENT BACKER BOARD
EXPANDING FOAM SEALANT AT
PERIMETER OF STUD CAVITY
PROVIDE
8" CHANNEL EACH SIDE
OF INSIDE PANEL FOR EXPANDING
PERIMETER FOAM SEAL
MANUFACTURED SHOWER PAN
EXPANDING FOAM
WOOD FRAME FLOOR ASSEMBLY
PROVIDE BLOCKING AT
STUD CAVITY SHOWER
EXTERIOR WALL
CONTINUOUS BEAD
OF SEALANT
TILE SURROUND FINISH
CEMENT BACKER BOARD
INSULATED EXTERIOR
STUD WALL
THIN-PROFILE WALL SHEATHING
MANUFACTURED SHOWER PAN
EXPANDING FOAM
WOOD FRAME FLOOR
ASSEMBLY
CEMENT BACKER BOARD
TUB SURROUND FINISH
(2) LAYERS RIGID INSULATION
EXPANDING FOAM SEALANT AT
PERIMETER OF STUD CAVITY
PROVIDE 3
8" CHANNEL EACH SIDE
OF INSIDE PANEL FOR EXPANDING
PERIMETER FOAM SEAL
EXPANDING FOAM
WOOD FRAME FLOOR
ASSEMBLY
TUB UNIT
CONTINUOUS BEAD OF SEALANT
CEMENT BACKER BOARD
TUB SURROUND FINISH
INSULATED EXTERIOR STUD WALL
CONTINUOUS BEAD OF SEALANT
PROVIDE BLOCKING AT STUD
CAVITY AT TUB ALONG EXTERIOR
WALL
EXPANDING FOAM
WOOD FRAME FLOOR ASSEMBLY
TUB UNIT
CONTINUOUS BEAD OF SEALANT
THIN-PROFILE WALL SHEATHING
CONTINUOUS BEAD OF SEALANT
CONTINUOUS BEAD OF ADHESIVE
FLOOR TRUSS ASSEMBLY
INTERIOR GYPSUM WALLBOARD
AS AIR BARRIER
MANUFACTURED THIN PROFILE
ATTIC VENTILATION BAFFLE
(FULL WIDTH)
VENTED AIRSPACE
ATTIC INSULATION
CONTINUOUS BEAD OF SEALANT
EXTERIOR INSULATED WALL
2" RIGID INSULATION
CAVITY INSULATION
CONTINUOUS BEAD OF SEALANT
PROVIDE STUD CAVITY
CLOSURE ON THE BACK
SIDE OF EACH STUD CAVITY
PROVIDE RIGID INSULATION
BAFFLE AROUND VENTILATION
CHUTE - FOAM SEAL PERIMETER
OF RIGID INSULATION
PROVIDE SOLID BLOCKING
BENEATH KNEE WALL
CAVITY INSULATION
EXPANDING FOAM SEALANT AT
RIGID INSULATION/ SUBFLOOR
INTERFACE
BAND JOIST INSULATION
CAVITY INSULATION
UNINSULATED KNEE WALL
RIGID INSULATION
CLOSURE AT INTERIOR OF
RAFTER CAVITY
RIGID INSULATION BAFFLE
AROUND VENTILATION CHUTE
- FOAM SEAL PERIMETER OF
RIGID INSULATION
METAL FLASHING
w/ 1
4" DRIP
4" THICK RIGID
INSULATION
PROTECTIVE COVERING
FINISH GRADE
SILL SEALER
CONTINUOUS
BEAD SEALANT
CONCRETE SLAB
6 MIL
POLYETHYLENE
(CONTINUOUS
UNDER ENTIRE
SLAB)
METAL FLASHING
w/
" DRIP
1" THICK RIGID
INSULATION
PROTECTIVE COVERING
FINISH GRADE
SILL SEALER
CONTINUOUS
BEAD SEALANT
CONCRETE SLAB
6 MIL
POLYETHYLENE
(CONTINUOUS
UNDER ENTIRE
SLAB)
INTERIOR
CONDITIONED SPACE
CAVITY INSULATION
CONTINUOUS BEAD
OF SEALANT
INTERIOR
CONDITIONED SPACE
INSULATED
DEMISING WALL
ROOM ABOVE
GARAGE
WOOD FLOOR
TRUSS ASSEMBLY
CAVITY INSULATION
1" RIGID
INSULATION, TYP.
2x2 SLEEPERS
16" O.C.
GARAGE
(UNCONDITIONED
SPACE)
INSTALL SHEATHING
ON TRUSS PRIOR TO
FRAMING WALL
CAVITY INSULATION
CAVITY INSULATION
RIGID INSULATION
AT SLOPE
CONDITIONED SPACE
VENTED
ATTIC
VENTED
ATTIC
INSTALL SHEATHING
ON TRUSS PRIOR TO
FRAMING WALL
CAVITY INSULATION
CAVITY INSULATION
RIGID INSULATION
AT SLOPE
UNCONDITIONED SPACE
VENTED
ATTIC
VENTED
ATTIC
-GENERAL NOTES
-SITE LOCATION
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
SITE PLAN 1"= 20'-0"
SECTION:79.13
BLOCK:1
LOT:13
IT IS A VIOLATION OF THE LAW FOR ANY
PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER AN ITEM IN ANY WAY
PROPOSED 2 STORY
SIDE ADDITION
PROPOSED 2 STORY
ADDITION
56.5'
EXISTING FOUNDATION PLAN 1/4"= 1'-0"
EXISTING FIRST FLOOR PLAN 1/4"= 1'-0"
EXISTING SECOND FLOOR PLAN 1/4"= 1'-0"
DN
8'-0"x8'-0"
GARAGE DOOR
GARAGE
8" TYPE 'X' GYPSUM
BOARD ON WALLS
& CEILING
PITCH SLAB 1
8"/FT.
TOWARDS DOOR
4" CONC. SLAB 3500
PSI w/ 6"x6" 10
10 W.W.M. &
6 MIL. PVC VAPOR
BARRIER
UP
DN
LINE OF FLOOR BELOW
LINE OF FLOOR BELOW
DN
BATH.
BEDROOM
#1
CRIB
ROOM
LIVING RM
KITCHEN
BEDROOM
#2
CLO.
DN
DN
NOTES:
·
DOUBLE UP ALL FRAMING UNDER PARALLEL PARTITIONS
·
DESIGN SHALL BE IN COMPLIANCE W/ RESIDENTIAL CODE
OF N.Y.S. 2025 & 2020 W.F.C.M.
·
STAIRS LANDING RAILS & GUARDS AS PER SECTION R312
·
OUTSIDE LIGHTING AS PER CODE
·
STAIRWAY ILLUMINATION AS PER CODE
·
FIRE BLOCK AS PER CODE
·
DRAFT STOPPING AS PER CODE
·
FLOOR DIAPHRAGM BRACING W.F.C.M. 3.3.5
·
ENTIRE WALL IS SHEAR WALL
·
SUBFLOOR TO BE GLUED & SCREWED
·
ALL WINDOWS ARE ANDERSON STOCK MODEL. SEE
LAYOUT FOR STOCK NUMBERS. 400 SEARIES
NOTE:
EGRESS WINDOW OPENINGS
5.7 SQ.FT. MIN.
5 SQ. FT. @ GRADE FLOOR
MIN. CLEAR HT. 24"
MIN. CLEAR W. 20"
NOT MORE THAN 44" A.F.F.
SEE SECTION R310
NOTE:
SMOKE DETECTOR/ALARM
·
EACH SLEEPING ROOM
·
OUTSIDE EACH SLEEPING AREA IN IMMEDIATE
VICINITY
·
ON EACH ADDITIONAL STORY INCLUDING
BASEMENTS/ CELLARS
·
HEAT DETECTOR REQUIRED IN ALL NEW
ATTACHED GARAGES. (R314.2.1)
SEE SECTION R314
CM ALARMS AS PER R315 OF THE 2025 RESIDENTIAL
CODE OF NYS & SECTION 915 OF THE 2020 FIRE
CODE OF NYS
CARBON MONOXIDE DETECTOR AS PER THE 2025
RESIDENTIAL CODE OF NEW YORK STATE & ARE
WITHIN 10 FEET OF ALL SLEEPING UNITS WHICH
CONTAIN NO FUEL SOURCE
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
BATH.
W
D
2'-6"x6'-8"
3'-0"x6'-8"
BARN DOOR
UP
4"X9" WD
BLOCK HDR
EXISTING
DIRECT
VENT
BOILER
HW
HEATER
UNFINISHED
BASEMENT
-EXISTING CONDITIONS
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
SITE PLAN 1"= 20'-0"
SECTION:79.13
BLOCK:1
LOT:13
IT IS A VIOLATION OF THE LAW FOR ANY
PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER AN ITEM IN ANY WAY
PROPOSED 2 STORY
SIDE ADDITION
PROPOSED 2 STORY
ADDITION
56.5'
PROPOSED FOUNDATION PLAN 1/4"= 1'-0"
8'-0"x8'-0"
GARAGE DOOR
UNFINISHED
BASEMENT
GARAGE
8" TYPE 'X' GYPSUM
BOARD ON WALLS
& CEILING
PITCH SLAB 1
8"/FT.
TOWARDS DOOR
4" CONC. SLAB 3500
PSI w/ 6"x6" 10
10 W.W.M. &
6 MIL. PVC VAPOR
BARRIER
PROPOSED FIRST PLAN 1/4"= 1'-0"
CRAWL
SPACE
BATH.
BATH.
STUDY
LIVING RM
PLAYROOM
ENCLOSED
PORCH
DN
UP
UP
7'-4"
30'-0"
4'-8"
12'-0"
30'-0"
42'-0"
6'-6"
14'-3"
28'-3"
7'-0"
20'-10 1/2"
5'-0"
8'-7"
11'-8"
29'-4"
13'-5 1/4"
13'-7 1/4"
13'-5 1/4"
KITCHEN
DINING RM
A
A
A
A
2-2"x8" HDR
3'-10"x4'-4"
D.H.WINDOW
#TW3842
3'-10"x4'-4"
D.H.WINDOW
#TW38342
2-2"x8" HDR
4'-0"x3'-0"
CASEMENT
#C23
2-2"x8" HDR
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
4'-8"
6'-6"
ELECTRIC FIREPLACE
15'-7"
11'-5"
DN
DN
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
3'-0"x6'-8"
BENCH
BENCH
2-2"x8" HDR
3'-0"x4'-4"
D.H.WINDOW
#TW21042
3'-10"x4'-4"
D.H.WINDOW
#TW3842
2-2"x8" HDR
NEW 8" CONC. FOUNDATION WALL w/2 #4
@24" O.C. VERTICAL BAR TOP & BOTTOM
CONT. OVER 24"x12" CONCRETE 'T' FOOTING
w/3 #4 BARS CONT. w/ #4 CROSS TIES @18"
O.C. w/ 2"x4" CONTINUOUS KEYWAY
UNEXCAVATED
2"x8" @ 16" O.C.
FLOOR JOIST
EXISTING
4" CONC. SLAB w/ 6"x6"
10 W.W.M. & 6 MIL. PVC
VAPOR BARRIER
4" CONC. SLAB w/ 6"x6"
10 W.W.M. & 6 MIL. PVC
VAPOR BARRIER
EXISTING 8" CONC. FOUNDATION
WALL w/2 #4 BAR TOP & BOTTOM
CONT. OVER 16"x8" CONCRETE
'T' FOOTING w/3 #4 BARS CONT.
w/ 2"x4" CONTINUOUS KEYWAY
7'-4"
7'-1"
7'-0"
35'-10"
43'-2"
4'-0"
15'-5"
28'-3"
5'-0"
7'-5"
9'-4"
3'-9"
6'-9"
8'-10"
7"
2'-6"
11"
4'-11"
6'-9"
43'-2"
42'-0"
1'-2"
11'-0"
7'-7"
11'-5"
12'-0"
2'-11"
6'-6"
2'-7"
7'-0"
4'-5"
2'-4"
3'-0"
2'-4"
5'-2"
5'-10"
28'-3"
7'-9"
3'-2"
11'-1"
14'-3"
13'-11"
6'-2"
14'-3"
13'-11"
1'-10"
SD/CO
SD/CO
PROVIDE #4 BAR @ 16" O.C.
VERTICALLY w/ MIN. 4"
PENETRATION INTO NEW &
EXISTING FOUNDATION &
WATERTIGHT JOINT, TYP.
2"x8" @ 16" O.C.
FLOOR JOIST
NEW
2" CONC. SLAB w/ 6"x6"
10 W.W.M. & 6 MIL. PVC
VAPOR BARRIER
W
D
2'-6"x6'-8"
3'-0"x6'-8"
BARN DOOR
PROVIDE VENT TO EXTERIOR
FOR DRYER AS PER G2439
NYS BUILDING CODE
2"x8" @ 16" O.C.
FLOOR JOIST
NEW
2"x8" @ 16" O.C.
PRESSURE TREATED
DECK JOIST
NEW
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x8" @ 16" O.C.
FLOOR JOIST
EXISTING
2"x8" @ 16" O.C.
FLOOR JOIST
EXISTING
2"x8" @ 16" O.C.
FLOOR JOIST
EXISTING
4"X9" WD BLOCK HDR
EXISTING
4"X9" WD
BLOCK HDR
EXISTING
EXISTING 31
2"Ø STL. COL.
BEARING ON 30"x30"x16"
CONC. FOOTING, TYP.
EXISTING 31
2"Ø STL. COL.
BEARING ON 30"x30"x16"
CONC. FOOTING, TYP.
NEW 31
2"Ø STL. COL.
BEARING ON 30"x30"x16"
CONC. FOOTING, TYP.
WP
WP
WP
B
B
C
C
WP
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
EXISTING WINDOW
D.H.
2-2"X10" HDR NEW
EXIST. R/O
CONC. PATIO
2-2"X8" w/ 1
2"X7"
STL PLATE HDR
DROPPED
PROVIDE 50 C.F.M.
EXHAUST FAN TO
EXHAUST EXTERIOR
2-2"X10" w/ 2-1
2"X8"
STL PLATE HDR
FLUSH
2-2"X10" w/ 2-1
2"X8"
STL PLATE HDR
FLUSH
2-2"X8" w/ 2-1
2"X8"
STL PLATE HDR
FLUSH
2-2"X10" w/ 2-1
2"X8"
STL PLATE HDR
FLUSH
WP
WP
WP
WP
WOOD POST TO ALIGN WITH
NEW STL. COLUMN BELOW
2-2"X8" HDR OVER 4"X4"
WOOD POST OVER 12"Ø
CONC. FOOTING, TYP.
LINE OF FLOOR ABOVE
2-2"X10" HDR
DROPPED
2-2"X10" HDR
DROPPED
B
B
C
C
1'-1" 6" 3'-0" 6"
3'-2"
4'-0"
2'-6"
2"x8" @ 16" O.C.
PRESSURE TREATED
DECK JOIST
NEW
2-2"X10" HDR
DROPPED
10"
6'-1 3/4"
6'-5 3/4"
6"
ZONING ANALYSIS: RESIDENCE ZONE RA-5
LOT SIZE:
PERMITTED
BLDG. COVERAGE:
USE:
HEIGHT:
FRONT YARD:
FRONT YARD: CORNER
SIDE YARD:
REAR YARD:
35' MAX.
30%
30'
N/A
10' MIN.
25' TOTAL
30'
RESIDENCE
RESIDENCE
RESIDENCE
5,000 S.F.MIN.
6,250 S.F
6,250 S.F
18'
30'
15.5%
21.1%
13.9'
25'
7.9'
68.5'
56.5'
ZONING ANALYSIS
USE
AREA
% USE
LOT
6250 S.F
100%
PROP.ADDITON
846.8 S.F
13.5%
28 S.F
.4%
R/O STEPS
338.7 S.F
5.4%
CONC. PLAT
12 S.F
.1%
LOT
EXIST.DWELLING
28 S.F
TOTAL
1323.5 S.F
21.1%
1.5%
SHED
98 S.F
2"x8" @ 16" O.C.
FLOOR JOIST
NEW
WALL TYPE SCHEDULE
NEW 2"x4" STUD WALL, FINISHED
NEW CONC. FOUNDATION WALL
NEW. 2"x6" STUD WALL, FINISHED
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x10" @ 16" O.C.
FLOOR JOIST
NEW
2"x10" @ 16" O.C.
CEILING JOIST
NEW
2"x10" @ 16" O.C.
CEILING JOIST
NEW
2"x10" @ 16" O.C.
CEILING JOIST
NEW
2"x10" @ 16" O.C.
CEILING JOIST
NEW
CLO.
PLAT.
REF
WP
WP
WP
WP
WP
WP
HD
13.9'
25'
7.9'
WP
DIRECT
VENT
BOILER
HW
HEATER
8" TYPE 'X' GYPSUM
BOARD ON CEILING &
WALLS, 5 FT. IN
EVERY DIRECTION
STAIRS W/ UNDER
STAIR PROTECTION
AS PER R-302.7
36" HIGH RAILING w/ 2"x2" SPINDLES
MAX. 4" APART AS PER (R312.2),
NOT TO ALLOW PASSAGE OF A
SPHERE 4" OR MORE IN DIAMETER
36" HIGH RAILING w/ 2"x2" SPINDLES MAX. 4"
APART AS PER (R312.2), NOT TO ALLOW PASSAGE
OF A SPHERE 4" OR MORE IN DIAMETER
4" CONC. SLAB w/ 6"x6"
10 W.W.M. & 6 MIL. PVC
VAPOR BARRIER
36" HIGH RAILING w/ 2"x2" SPINDLES
MAX. 4" APART AS PER (R312.2),
NOT TO ALLOW PASSAGE OF A
SPHERE 4" OR MORE IN DIAMETER
2"x8" @ 16" O.C.
FLOOR JOIST
EXISTING
PROVIDE #4 BAR @ 16" O.C.
VERTICALLY w/ MIN. 4"
PENETRATION INTO NEW &
EXISTING FOUNDATION &
WATERTIGHT JOINT, TYP.
3'-0"x3'-0"
CRAWL SPACE
OPENING
8"X16"
VENT, TYP.
8"X16" VENT, TYP.
8"X16"
VENT, TYP.
8"X16" VENT, TYP.
R
E
E
E
E
E
-PROPOSED FOUNDATION PLAN
-PROPOSED FIRST FLOOR PLAN
-SITE LOCATION
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
LINE OF FLOOR BELOW
LINE OF FLOOR BELOW
PROPOSED SECOND PLAN 1/4"= 1'-0"
DN
BEDROOM
#1
BEDROOM
#2
BATH.
MASTER
BATH.
MASTER
BEDROOM
10'-7 1/2"
11'-3 1/4"
11'-1 1/4"
A
A
2'-0"x3'-0"
D.H.WINDOW
#TW20210
2-2"x8" HDR
3'-2"x4'-8"
D.H.WINDOW
#TW3046
2-2"x8" HDR
2-2"x8" HDR
3'-2"x4'-8"
D.H.WINDOW
#TW3046
2-2"x8" HDR
3'-2"x4'-8"
D.H.WINDOW
#TW3046
2-2"x8" HDR
3'-2"x4'-8"
D.H.WINDOW
#TW3046
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
2'-6"x6'-8"
4'-0"x6'-8"
SLIDING DOOR
2'-6"x6'-8"
10'-1 1/4"
10'-7 1/4"
2'-0"
3'-4"
3'-0"
2-2"x8" HDR
3'-2"x4'-8"
D.H.WINDOW
#TW3046
4'-0"x6'-8"
SLIDING DOOR
2'-6"x6'-8"
4'-0"x6'-8"
SLIDING DOOR
4'-0"x6'-8"
SLIDING DOOR
W.I.C.
CLO.
CLO.
CLO.
CLO.
2'-6"x6'-8"
SD
SD
SD
SD
READING
RM
CLO.
6'-1 3/4"
9'-11 3/4"
6'-7 3/4"
10'-1 3/4"
9'-10"
12'-0"
11'-10"
4'-4"
6'-10"
5'-0"
10'-5 1/2"
3'-9 3/4"
16'-4"
2'-0"
26"x55" PULL DOWN ATTIC
STAIR. DOUBLE UP ALL
FRAMING AROUND TO BE
WEATHER STRIPPED AND
INSULATED AS PER N1102.2.4
BEDROOM
#3
2-2'-6"x4'-8"
D.H.WINDOW
#TW2446
2-2"x8" HDR
2'-6"x6'-8"
15'-9"
5'-4"
15'-1"
4'-0"
36'-2"
42'-0"
4'-2"
1'-8"
28'-3"
28'-3"
7'-9"
11'-10"
8'-7"
1'-10"
10'-2"
5'-4"
7'-4"
4'-0"
36'-2"
42'-0"
1'-10"
6'-9"
6'-7"
15'-8"
6'-9"
2'-0"x3'-0"
D.H.WINDOW
#TW20210
2-2"x8" HDR
2'-0"
2"x8" @ 16" O.C.
CEILING JOIST
NEW
2"x8" @ 16" O.C.
CEILING JOIST
NEW
2"x8" @ 16" O.C.
CEILING JOIST
NEW
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
2"x12" @ 16" O.C.
ROOF RAFTERS
NEW
2"x12" @ 16" O.C.
ROOF RAFTERS
NEW
2-2"x12" HDR
6'-8"x4'-6"
BAYWINDOW
#90-C345-15
PROVIDE 50 C.F.M.
EXHAUST FAN TO
EXHAUST EXTERIOR
PROVIDE 50 C.F.M.
EXHAUST FAN TO
EXHAUST EXTERIOR
2-2"X12"
HDR
2-2"X12"
HDR
2-2"x12" HDR
6'-8"x4'-6"
BAYWINDOW
#90-C345-15
WOOD POST TO
ALIGN WITH NEW
STL. COLUMN
BELOW
6'-3 3/4"
B
B
SD/CO
3-2"x12"
HDR
3-2"x12"
HDR
3-2"x12"
HDR
LINE OF FLOOR BELOW
2"x8" @ 16" O.C.
ROOF RAFTERS
NEW
2"x8" @ 16" O.C.
ROOF RAFTERS
NEW
2"x8" @ 16" O.C.
ROOF RAFTERS
NEW
2"x8" @ 16" O.C.
ROOF RAFTERS
NEW
LINE OF
PATIO BELOW
WP
WP
WP
WP
WP
WP
WP
LINE OF FLOOR BELOW
LINE OF FLOOR BELOW
LINE OF FLOOR BELOW
2"x12" ROOF RAFTERS @ 16" O.C.
2"x10" VALLEY RAFTER
2-2"x12" RIDGE
2"x4" COLLAR TIES @ 48" O.C.
2"x8" ROOF RAFTERS @ 16" O.C.
2"x8" ROOF RAFTERS @ 16" O.C.
2"x4" COLLAR TIES @ 48" O.C.
ROOF CONSTRUCTION:
ASPHALT SHINGLES OVER #30 FELT PAPER OVER 1
2" CDX
PLYWOOD OVER 2"x12" ROOF RAFTERS @ 16" O.C.
2"x12" ROOF RAFTERS @ 16" O.C.
2"x8" ROOF RAFTERS @ 16" O.C.
2"x8" ROOF RAFTERS @ 16" O.C.
ROOF PLAN 1/4"= 1'-0"
ANDERSEN WINDOW SCHEDULE 400 SERIES
8"THREADED ROD
(2) 2x PLATE
UPPER
2x WALL
LOWER
2x WALL
(2) 2x PLATE
(2) FLOOR
JOIST
BLOCKING
HOLDOWN CONNECTION "HD" DETAIL
SIMPSON HDQ8 OR
SIMPSON PHD6 HOLDOWN
SIMPSON HDQ8 OR
SIMPSON PHD6 HOLDOWN
#TW21042
4.92
8.84
4.95
13.08
---
6.47
11.89
6.5
16.75
---
8.5
7.9
---
#TW3842
#C23
2.16
3.68
2.18
6.56
TEMPERED GLASS
#TW20210
5.82
10.31
5.75
14.85
EGRESS
#TW3046
---
---
---
---
BAY WINDOW
#90-C345-15
4.44
7.65
4.39
11.7
---
#TW2446
3'-2"
3'-0"
6'-1 3/4"
CUSTOM
---
---
---
---
PORCH WINDOW
R402.2.1 CEILINGS WITH ATTIC SPACES
WHERE SECTION R1102.1.2 REQUIRES R-38 INSULATION IN THE CEILING, INSTALLING R-30
INSULATION OVER 100 PERCENT OF THE CEILING AREA REQUIRING INSULATION SHALL
SATISFY THE REQUIREMENT FOR R-38 INSULATION WHEREVER THE FULL HEIGHT OF
UNCOMPRESSED R-30 INSULATION EXTENDS OVER THE WALL TOP PLATE AT THE EAVES.
WHERE SECTION
N1102.1.2 REQUIRES R-49 INSULATION IN THE CEILING, INSTALLING R-38 INSULATION OVER 100
PERCENT OF THE CEILING AREA REQUIRING INSULATION SHALL SATISFY THE REQUIREMENT
FOR R-49 INSULATION WHEREVER THE FULL HEIGHT OF UNCOMPRESSED R-38 INSULATION
EXTENDS OVER THE WALL TOP PLATE AT THE EAVES. THIS REDUCTION SHALL NOT APPLY TO
THE U-FACTOR ALTERNATIVE APPROACH IN SECTION N1102.1.4 AND THE TOTAL UA
ALTERNATIVE IN SECTION N1102.1.5
R402.2.4 ACCESS HATCHES AND DOORS
ACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SUCH S ATTICS
AND CRAWL SPACES SHALL BE WEATHER-STRIPPED AND INSULATED TO A LEVEL
EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. ACCESS THAT
PREVENTS DAMAGING OR COMPRESSING THE INSULATION SHALL BE PROVIDED TO ALL
EQUIPMENT.
WHERE LOOSE-FILL INSULATION IS INSTALLED, A WOOD-FRAMED OR EQUIVALENT BAFFLE OR
RETAINER SHALL BE INSTALLED TO PREVENT THE LOOSE-FILL INSULATION FROM SPILLING
INTO THE LIVING SPACE WHEN THE ATTIC ACCESS IS OPENED. THE BAFFLE OR RETAINER
SHALL PROVIDE A PERMANENT MEANS OF MAINTAINING THE INSTALLED R-VALUE OF THE
LOOSE-FILL INSULATION
WALL TYPE SCHEDULE
NEW 2"x4" STUD WALL, FINISHED
NEW CONC. FOUNDATION WALL
NEW. 2"x6" STUD WALL, FINISHED
2-2"x8" HDR
3'-0"x4'-4"
D.H.WINDOW
#TW21042
-PROPOSED SECOND FLOOR PLAN
-PROPOSED ROOF PLAN
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
SECTION A-A 1/4"= 1'-0"
29'-11"
2'-8"
8'-0"
10"
8'-0"
6'-8"
FIN. CEILING
FIN. FL.
T.O.
ROOF
FIN. CEILING
T.O. WINDOW
FIN. FL.
6'-8"
T.O.
WINDOW
GRADE
FIN. CEILING
D8, OR D10 & D15
D2
D6
D1
ROOF CONSTRUCTION:
ASPHALT SHINGLES OVER #30 FELT PAPER OVER 1
2" CDX
PLYWOOD OVER 2"x12" ROOF RAFTERS @ 16" O.C.
ICE SHIELD TO RUN BACK 2'-0" FROM INTERIOR OF EXTERIOR
WALL AS PER R905.1.2 & R905.2.7 OF THE NYS CODE
2-2"x12" RIDGE
2"x4" COLLAR TIES @ 48" O.C.
2-2"x4" PLATE. CONTINUOUS SOFFIT & 1"x6" FASCIA
CEILING CONSTRUCTION:
2"x8" CEILING JOIST @ 16" O.C. R-38 INSULATION w/ 1
2" GYP BOARD.
3 COATS TAPE & SPACKLE. DO NOT COMPRESS INSULATION
AT FOUNDATION:
PROVIDE 11
2" x 20 GA. GALVANIZED STRAPPING FROM FIRST
FLOOR WALL STUDS OVER BOX BEAM & SILL PLATE, TO BE
WRAPPED AT THE SILL PLATE & BROUGHT UNDER THE PLATE &
SECURED INTO THE TOP OF THE PLATE @ 16" O.C. W/ MIN.
OVERLAP AT STUDS OF 12". NAILING AS PER TABLE 3.4B WFCM
TAR WATERPROOFING
8" CONC. FOUNDATION WALL w/2 #4 @24" O.C.
VERTICAL BAR TOP & BOTTOM CONT. OVER 24"x12"
CONCRETE 'T' FOOTING w/3 #4 BARS CONT. w/ #4
CROSS TIES @18" O.C. w/ 2"x4" CONTINUOUS KEYWAY
FLOOR CONSTRUCTION:
4" PLYWOOD SUBFLOOR OVER 2"x8" @16" FLOOR JOIST w/
R-30 BATT INSULATION
AT PLATE, RAFTER CONNECTOR:
PROVIDED 11
2"x 20 GA. GALVANIZED STRAPPING AT BIRDS
MOUTH & RAFTER CONNECTION @ 16" O.C. W/MIN. OVERLAP
AT STUDS OF 12". NAILING AS PER TABLE 3.4B WFCM
WALL CONSTRUCTION:
VINYL SIDING OVER 1" IR RIGID INSULATION (R-5) OVER
TYVEK HOUSE WRAP OVER 1
2" CDX PLYWOOD SHEATHING
OVER 2"x6" STUDS @ 16" O.C. w/ R-30 INSULATION &
FINISHED w/ 1
2" GYP. BOARD. 3 COATS TAPE & SPACKLE.
PROVIDE 11
2"x 20 GA. GALVANIZED STRAPPING FROM SECOND
FLOOR WALL STUDS TO FIRST FLOOR WALL STUDS @ 16" O.C. w/
A MIN. OVERLAP OF 12" AND NAILED AS PER TABLE 3.3B WFCM
2 - 2"x6" ACQ TREATED SILL w/ COPPER TERMITE SHIELD w/5
8"Ø
DOUBLE HOT DIPPED GALVANIZED ANCHOR BOLTS @ 28" O.C.
(NO GREATER THAN 39" MAX, THOUGH IT CAN BE LESS) 12"
MAX. TO EACH CORNER AS PER TABLE (3.3A WFCM)
WALL CONSTRUCTION:
VINYL SIDING OVER 1" IR RIGID INSULATION (R-5) OVER
TYVEK HOUSE WRAP OVER 1
2" CDX PLYWOOD SHEATHING
OVER 2"x6" STUDS @ 16" O.C. w/ R-30 INSULATION &
FINISHED w/ 1
2" GYP. BOARD. 3 COATS TAPE & SPACKLE.
FLOOR CONSTRUCTION:
4" PLYWOOD SUBFLOOR OVER 2"x10" @16" FLOOR JOIST
3'-0"
KITCHEN
PLAYROOM
MASTER
BEDROOM
READING
RM
W.I.C.
CRAWL SPACE
SECTION B-B 1/4"= 1'-0"
GRADE
36" HIGH RAILING w/ 2"x2" SPINDLES
MAX. 4" APART AS PER (R312.2),
NOT TO ALLOW PASSAGE OF A
SPHERE 4" OR MORE IN DIAMETER
AT FOUNDATION:
PROVIDE 11
2" x 20 GA. GALVANIZED STRAPPING FROM FIRST
FLOOR WALL STUDS OVER BOX BEAM & SILL PLATE, TO BE
WRAPPED AT THE SILL PLATE & BROUGHT UNDER THE PLATE &
SECURED INTO THE TOP OF THE PLATE @ 16" O.C. W/ MIN.
OVERLAP AT STUDS OF 12". NAILING AS PER TABLE 3.4B WFCM
TAR WATERPROOFING
8" CONC. FOUNDATION WALL w/2 #4 @24" O.C.
VERTICAL BAR TOP & BOTTOM CONT. OVER 24"x12"
CONCRETE 'T' FOOTING w/3 #4 BARS CONT. w/ #4
CROSS TIES @18" O.C. w/ 2"x4" CONTINUOUS KEYWAY
2 - 2"x6" ACQ TREATED SILL w/ COPPER TERMITE SHIELD w/5
8"Ø
DOUBLE HOT DIPPED GALVANIZED ANCHOR BOLTS @ 28" O.C.
(NO GREATER THAN 39" MAX, THOUGH IT CAN BE LESS) 12"
MAX. TO EACH CORNER AS PER TABLE (3.3A WFCM)
WALL CONSTRUCTION:
VINYL SIDING OVER 1" IR RIGID INSULATION (R-5) OVER
TYVEK HOUSE WRAP OVER 1
2" CDX PLYWOOD SHEATHING
OVER 2"x6" STUDS @ 16" O.C. w/ R-30 INSULATION &
FINISHED w/ 1
2" GYP. BOARD. 3 COATS TAPE & SPACKLE.
ROOF CONSTRUCTION:
ASPHALT SHINGLES OVER #30 FELT PAPER OVER 1
2" CDX
PLYWOOD OVER 2"x8" ROOF RAFTERS @ 16" O.C.
2"x10" PRESSURE TREATED LEDGER LAG BOLTED TO FRAMING
W/ 1.2" Ø GALV. BOLTS & WASHERS @ 16" O.C. (STAGGERED)
2-2"x4" PLATE. CONTINUOUS SOFFIT & 1"x6" FASCIA
AT PLATE, RAFTER CONNECTOR:
PROVIDED 11
2"x 20 GA. GALVANIZED STRAPPING AT BIRDS
MOUTH & RAFTER CONNECTION @ 16" O.C. W/MIN. OVERLAP
AT STUDS OF 12". NAILING AS PER TABLE 3.4B WFCM
SUNROOM
CRAWL
SPACE
MASTER
BEDROOM
KITCHEN
(2)2"x8" PRESSURE TREATED GIRDER ON PRESSURE TREATED
4"x4" POST SECURED ON 8"Ø POURED CONC. PIER FOOTING MIN.
3'-0" BELOW FINISHED GRADE - TYP.
4"x6" PRESSURE TREATED WOOD DECKING w/1
8" SPACING
OVER 2"x8" DECK JOIST @ 16" O.C.
(2)2"x10" PRESSURE TREATED GIRDER ON PRESSURE TREATED
4"x4" POST SECURED ON 12"Ø POURED CONC. PIER FOOTING MIN.
3'-0" BELOW FINISHED GRADE - TYP.
ROOF CONSTRUCTION:
ASPHALT SHINGLES OVER #30 FELT PAPER OVER 1
2" CDX
PLYWOOD OVER 2"x12" ROOF RAFTERS @ 16" O.C.
2-2"x12" RIDGE
2"x4" COLLAR TIES @ 48" O.C.
CEILING CONSTRUCTION:
2"x8" CEILING JOIST @ 16" O.C. R-38 INSULATION w/ 1
2" GYP BOARD.
3 COATS TAPE & SPACKLE. DO NOT COMPRESS INSULATION
(2)2"x10" PRESSURE TREATED GIRDER ON PRESSURE
TREATED 4"x4" POST SECURED ON POURED CONC.
PIER FOOTING MIN. 3'-0" BELOW FINISHED GRADE - TYP.
4"x6" PRESSURE TREATED WOOD DECKING w/1
8" SPACING
OVER 2"x8" DECK JOIST @ 16" O.C.
SECTION C-C 1/4"= 1'-0"
GRADE
(2)2"x10" PRESSURE TREATED
GIRDER ON PRESSURE TREATED
4"x4" POST SECURED ON POURED
CONC. PIER FOOTING MIN. 3'-0"
BELOW FINISHED GRADE - TYP.
ROOF CONSTRUCTION:
ASPHALT SHINGLES OVER #30 FELT PAPER
OVER 1
2" CDX PLYWOOD OVER 2"x8" ROOF
RAFTERS @ 16" O.C.
2"x10" PRESSURE TREATED LEDGER LAG
BOLTED TO FRAMING W/ 1.2" Ø GALV. BOLTS
& WASHERS @ 16" O.C. (STAGGERED)
2'-4"
7'-7"
13'-1"
T.O. WD POST
FIN. FL.
T.O.ROOF
3'-0"
R/O
CONC.
PATIO
CEILING CONSTRUCTION:
2"x8" CEILING JOIST @ 16" O.C. R-38 INSULATION w/ 1
2" GYP BOARD.
3 COATS TAPE & SPACKLE. DO NOT COMPRESS INSULATION
4" VENT THRU ROOF MIN.
18" ABOVE ROOF
SURFACE RP-3103.1
TO EXISTING
SANITARY SYSTEM
RISER DIAGRAM N.T.S.
C.O.
4"
WC
2"
C.O.
LAV.
2"
4"
WASHER
4"
BASEMENT
1ST FLOOR
2"
2"
2"
2"
SHOWER
2"
ROOF
2"
2"
C.O.
4"
WC
2"
C.O.
LAV.
2"
4"
DW
4"
2"
2"
2"
2"
SHOWER
2"
LAV.
LAV.
4"
WC
2"
C.O.
LAV.
2"
4"
SHOWER
2"
2"
2"
C.O.
4"
WC
LAV.
SHOWER
LAV.
2"
4"
WC
SHOWER
2"
2"
2"
2"
2"
4"
WC
LAV.
2"
2"
LAV.
LAV.
4"
2"
2"
NOTE:
- P3103.1 ROOF EXTENSION: OPEN VENT PIPES THAT EXTEND THROUGH THE
ROOF SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE ROOF OR 6
INCHES ABOVE THE ANTICIPATED SNOW ACCUMULATION, WHICHEVER IS
GREATER. WHERE A ROOF IS TO BE USED FOR ASSEMBLY, AS A PROMENADE,
OBSERVATION DECK OR SUNBATHING DECK OR FOR SIMILAR PURPOSES, OPEN
VENT PIPES SHALL TERMINATE NOT LESS THAN 7 FEET ABOVE THE ROOF.
- P3103.2 FROST CLOSURE: WHERE THE 97.5% VALUE FOR OUTSIDE DESIGN
TEMPERATURE IS 0°F(-18°C) OR LESS, VENT EXTENSIONS THROUGH A ROOF OR
WALL SHALL BE NOT LESS THAN 3 INCHES IN DIAMETER. ANY INCREASE IN THE
SIZE OF THE VENT SHALL BE MADE NOT LESS THAN 1 FOOT INSIDE THE THERMAL
ENVELOPE OF THE BUILDING
2"
2"
2"
2"
FLOOR CONSTRUCTION:
4" PLYWOOD SUBFLOOR OVER 2"x8" @16"
FLOOR JOIST w/ R-30 BATT INSULATION.
DO NOT COMPRESS. FUR OUT F.J. AS REQ.
-SECTION A-A
-SECTION B-B
-SECTION C-C
-RISER DIAGRAM
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
GRADE
LEFT SIDE ELEVATION 1/4"= 1'-0"
GRADE
GRADE
RIGHT SIDE ELEVATION 1/4"= 1'-0"
FRONT ELEVATION 1/4"= 1'-0"
GRADE
REAR ELEVATION 1/4"= 1'-0"
GRADE
29'-11"
2'-8"
8'-0"
10"
8'-0"
6'-8"
FIN. CEILING
FIN. FL.
T.O.
ROOF
FIN. CEILING
T.O. WINDOW
FIN. FL.
6'-8"
T.O.
WINDOW
FIN. CEILING
29'-11"
2'-8"
8'-0"
10"
8'-0"
6'-8"
FIN. CEILING
FIN. FL.
T.O.
ROOF
FIN. CEILING
T.O. WINDOW
FIN. FL.
6'-8"
T.O.
WINDOW
FIN. CEILING
29'-11"
2'-8"
8'-0"
10"
8'-0"
6'-8"
FIN. CEILING
FIN. FL.
T.O.
ROOF
FIN. CEILING
T.O. WINDOW
FIN. FL.
6'-8"
T.O.
WINDOW
FIN. CEILING
29'-11"
2'-8"
8'-0"
8'-0"
6'-8"
6'-8"
T.O.
ROOF
FIN. CEILING
T.O.
WINDOW
FIN. FL.
FIN. CEILING
T.O. WINDOW
FIN. FL.
-FRONT & REAR ELEVATION
-LEFT & RIGHT SIDE ELEVATION
11-21-25 ISSUED FOR PRELIMINARY REVIEW
11-26-25 ISSUED FOR PRELIMINARY REVIEW
12-04-25 ISSUED FOR PRELIMINARY REVIEW
12-22-25 ISSUED FOR PRELIMINARY REVIEW
01-06-26 ISSUED FOR ARCHITECTURAL REVIEW
02-05-26 ISSUED FOR BUILDING PERMIT REVIEW
555 BROADHOLLOW RD #327, MELVILLE, NY, 11747
PHONE # (516) 942-4224 WEB: https://mynextgendesigns.com
NEXTGENSOULTIONSNY@GMAIL.COM
PROJECT:
IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING
UNDER THE DIRECTION OF THE LICENSED ARCHITECT, TO ALTER
THESE PLANS IN ANY WAY. BY ACCEPTING AND USING THESE PLANS,
THE OWNER, CONTRACTOR, AND/OR AGENT AGREES TO LIMIT THE
LIABILITY OF THE DESIGN PROFESSIONAL AND THEIR EMPLOYEES
FOR ANY ACTS OF NEGLIGENCE OR ERROR. THE TOTAL AGGREGATE
LIABILITY SHALL NOT EXCEED THE TOTAL FEE FOR SERVICES
RENDERED ON THIS PROJECT.
SHEET NUMBER
OF
ISSUE:
TITLE:
100 YOUNG AVE, CROTON-HUDSON, NY, 10520
DILLON RESIDENCE
PROP. 1ST & 2ND FLOOR ADDITION
PROJECT#:251121
DRAWN BY: NGD
TM#:79.13-1-13
Machine-extracted for search and reference — the original PDF is the authoritative version.