39 Palmer Ave Complete Plans ZBA
map survey
6 pages
From the meeting:
Zoning Board of Appeals — 2026-04-21
· our coverage →
Agenda item: NEW PUBLIC HEARING — Maragaret Crocker, owner---39 Palmer Ave---Located in a RA5 Residence District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 78.08 Block 4 Lot 19. Request for a front yard and rear yard variance from Village Zoning Code Section 230-33(A) for a proposed addition.
Map / plans, 6 pages. Attached to agenda item: “NEW PUBLIC HEARING — Maragaret Crocker, owner---39 Palmer Ave---Located in a RA5 Residence District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 78.08 Block 4 Lot 19. Request for a front y”
Retrieved 2026-04-18 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
39 Palmer Ave ZBA Application Redacted
Extracted text
LENGTH
SPAN
CLEAR
specified nails in
Equal number of
end distance
Provide minimum 1"
each end
END
LENGTH
EACH SIDE OF STUD
(3)10dx1 1/2" NAILS
W
DIAMETER
BOLT
+
1"
L
SIMPSON STRONG-TIE
STRAP TIES
(CS16)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
ADJUSTABLE & STANDOFF POST
BASE
(ABA44)
AT EA. POST ANCHORED TO
CONCRETE
SIMPSON STRONG-TIE
STUD PLATE TIES (LIGHT GAUGE STEEL)
(SP4 / SSP)
SSP FOR SINGLE STUD
(2) SSP FOR DOUBLE STUD
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
BEARING PLATE
(BP)
BASE PLATE @ EA. ANCHOR
BOLT TO FOUNDATION
(3)10dx1 1/2" NAILS
SP4
SSP
Simpson Strong-Tie
FTA
SIMPSON STRONG-TIE
FLOOR TIE ANCHORS
(FTA / LFTA)
INSTALLED @ 32"O.C.
SIMPSON Strong-Tie
SIMPSON Strong-Tie
@
sheathing
LTP4 on
plywood
G
May not be
installed over
sheathing
A35F
J
H
SIMPSON STRONG-TIE
STRAP TIES
(MSTI)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
FRAMING ANGLES & PLATES
(LTP4 / A35F)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
TWIST STRAP
(MTS)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
COILED STRAP (LIGHT GAUGE STEEL)
ADJUSTABLE LIGHT SLOPEABLE / SKEWABLE U
HANGER
(CS20 / LSSU28)
INSTALLED @ 32"O.C.
CS20 FOR RIDGE
COMBINATION CS20 / LSSU28 FOR STRUCTURAL
LSSU28
LSSU28
SIMPSON STRONG-TIE
ADJUSTABLE LIGHT SLOPEABLE /
SKEWABLE U HANGER
(LSSU28)
INSTALLED @ 32"O.C.
AREAS OF WORK
8'-7"
6'-0"
7'-4"
12'-5"
13'-9"
11'-4"
8'-7"
9'-10"
N
39 PALMER AVENUE
CROTON ON HUDSON, NY 10520
DRAWING LIST
A-1
COVER SHEET
A-4
A-5
ELEVATIONS & DETAILS
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
COVER
SHEET
A-1
SECTIONS DETAIL POWER &
LIGHTING PLAN
SITE PLAN
SCALE 1"=10'-0"
A-2
GENERAL NOTES & DETAILS
CONNECTION DETAILS
A-3
CONSTRUCTION PLANS
9/ 01/ 2025
R310.1.1 OPERATIONAL CONSTRAINTS
EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF
KEYS OR TOOLS.
R905.2.5 FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL,
STAINLESS STEEL, ALUMINUM OR COPPER ROOFING NAILS, MIN. 12
GAGE SHANK W/ A MIN. 3/8" HEAD ASTMF 1667, OF A LENGTH TO
PENETRATE THROUGH THE ROOFING MATERIAL AND A MIN. OF 3/4"
INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS
THAN 3/4" THICK, THE FASTENERS SHALL PENETRATE THROUGH THE
SHEATHING. FASTENERS SHALL COMPLY W/ ASTM F 1667.
R905.2.7 ICE SHIELD
ALL ROOF EAVES SHALL BE PROVIDED WITH ICE SHIELD MEMBRANE
FROM EDGE TO 24" PAST INSIDE WALL
SMOKE DETECTORS:
SMOKE DETECTORS SHALL BE INSTALLED AS PER THE
RESIDENTIAL NEW YORK STATE BUILDING CODE SUPPLEMENT
SECTION AJ504
R905.1.1 UNDERLAYMENT APPLICATION
FOR ROOF SLOPES FROM TWO VERTICAL UNITS IN 12
UNITS HORIZ. UP TO FOUR UNITS VERT. IN 12 UNITS HORIZ.
UNITS SHALL BE TWO LAYERS.
R905.2.6 ATTACHMENT
ASPHALT ROOF SHINGLES SHALL HAVE A MIN. OF SIX FASTENERS
PER SHINGLE WHERE THE ROOF IS IN ONE OF THE FOLLOWING
CATEGORIES - THE BASIC WIND SPEED PER R301.2(4) IS 110 MPH OR
GREATER AND THE EAVE IS 20' OR HIGHER ABOVE GRADE .
R310.2.1 MINIMUM OPENING WIDTH
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 20 INCHES.
R310.2.2 MINIMUM OPENING HEIGHT
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES.
R310.2.1 MINIMUM OPENING AREA
AL EMERGENCY ESCAPE AND RESCUE OPENINGS SHAL HAVE A
MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT. EXCEPTION GRADE FLOOR
OPENINGS SHAL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQ. FT.
EGRESS WINDOWS:
TABLE 1607.1
MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
TABLE R303.1
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
PROPOSED PROJECT SHALL COMPLY WITH THE FOLLOWING:
TABLE R602.3(1)
FASTENERS SCHEDULE FOR STRUCTURAL MEMBERS
GUARDRAILS AND HANDRAILS
STAIRS
SLEEPING ROOMS
ROOMS OTHER THAN SLEEPING
ATTICS WITH STORAGE
ATTICS WITHOUT STORAGE
PASSENGER VEHICLE GARAGES
DECKS
EXTERIOR BALCONIES
LIVE LOADS
USE
MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
(IN LBS. PER SQ. FT.)
DESIGN CRITERIA
SECTION R302 TABLE 302.1 ALL CONSTRUCTION WITH-IN 5'-0" OF
PROPERTY LINE TO BE 1HR RATED. BEYOND 5'-0" NO RATING IS
REQUIRED
YES
SLIGHT TO
MODERATE
MODERATE
TO HEAVY
3'-6"
SEVERE
C
30LB/FT
FLOOD HAZARDS
ICE SHEILD
UNDERLAYMENT
REQUIRED
WINTER
DESIGN
TEMP.
DECAY
TERMITE
FROST LINE
DEPTH
WEATHERING
SUBJECT TO DAMAGE FROM
SEISMIC
DESIGN
CATEGORY
GROUND
SNOW
LOAD
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
WIND
SPEED
(MPH)
FIRM MAP DEC 199
HEATING DEGRE DAYS
SECTION 303.1
LIGHT & VENT
SECTION R310
EMERGENCY ESCAPE
SECTION R1609.1.1
WIND-BORNE DEBRIS
SECTION 905.1.2
ICE SHIELD
SECTION R406
WATERPROOFING & DAMPPROOFING
SECTION R406.3.2
VAPOR BARRIER
SECTION R403.1.6
ANCHOR BOLTS
SECTION R403.3.4
TERMITE SHIELD
ALL FRAMING SHALL COMPLY WITH NYS R802
THE SPACE IS TO BE EQUIPPED WITH A HARDWIRED BATTERY
BACKED UP SMOKE DETECTOR.
ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED
ELECTRICIAN
THE SPACE IS TO BE EQUIPPED WITH A HARDWIRED
BATTERY BACKED UP CO2 DETECTOR.
NOTES:
LIGHTING FIXTURES NOTED ARE TO BE SUPPLIED BY OWNER
& INSTALLED BY G.C.
HVAC CONTRACTOR TO PROVIDE COMPLETE MANUAL J
CALCULATIONS AND EQUIPMENT SCHEDULES SHOWING
COMPLIANCE TO BUILDING DEPARTMENT FOR APPROVAL PRIOR
TO ORDERING ANY EQUIPMENT
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER
THE DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND
SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF
AN ENGINER OR LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR
LAND SURVEYOR SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE
NOTATION "ALTERED BY" FOLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
BASED UPON NFIP FIRM MAP THE PROJECT IS IN THE 'X'
FLOOD ZONE
THIS PROJECT WAS DESIGNED USING THE CURRENT NYS BUILDING CODE (2025 NYS RESIDENTIAL BUILDING CODE)
PROPOSED PROJECT SHALL COMPLY WITH THE FOLLOWING ADDITIONAL SECTIONS OF 2025 NYS RESIDENTIAL BUILDING CODE
SURVEY AS PROVIDED BY HOME OWNER
ALL WORK SHALL CONFORM TO THESE DRAWINGS, THE NEW
YORK STATE BUILDING CODE AND ANY OTHER APPLICABLE
CODES OR ORDINANCE THAT MAY APPLY TO THIS PROJECT
ALL DECK FRAMING LUMBER TO BE PRESSURE TREATED
SOUTHERN YELLOW PINE (#2 OR BETTER)
ALL CONCRETE FOOTINGS SHALL CONFORM TO ACI 318.77,
AND DEVELOP A STRENGTH OF 3,000PSI BEARING IN 28 DAYS
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS, EXISTING & PROPOSED, ANY DISCREPANCY
SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT.
THIS DECK HAS BEEN DESIGNED FOR
LIVE LOAD 40 LBS/SQFT
DEAD LOAD 10 LBS /SQFT
RAILING LATERAL 50 LBS/ SQFT THRUST
SOIL BEARING 3,000 LBS/ SQFT (ASSUMED)
LOADING
DECK FRAMING SHALL COMPLY WITH NYS R507 (1BC 2015) &
(FIGURE 507.2.1(2), 507.2.3 (1), 507.2.3 (2))
MIN TREAD LENGTH COMPLIES WITH NYS CODE R311.5.3.2
HANDRAIL TO HAVE GRASPABLE EDGE TO COMPLY WITH NYS
CODE R311.5.6
IF LEDGE ROCK IS ENCOUNTERED FOOTING ARE TO BE
PINNED TO THE LEDGE WITH (3) 6" #4 REBAR WITH 3" MIN
EMBEDMENT INTO THE STONE
STRUCTURAL SCREWS MAY BE SUBSTITUTED FOR THRU
BOLTING IS EQUIVALENT SIZES ARE USED
G.C. SHALL BE RESPONSIBLE FOR RUNNING GAS / PROPANE LINE
FROM TANK TO NEW FIREPLACE
G.C. SHALL BE RESPONSIBLE FOR PURCHASE & INSTALLATION
OF TOILET FIXTURES AS DIRECTED / SELECTED BY HOMEOWNER
G.C. SHALL BE RESPONSIBLE FOR PURCHASE & INSTALLATION
ALL LIGHT FIXTURES (INTERIOR & EXTERIOR)AS SELECTED BY
HOMEOWNER
G.C. SHALL BE RESPONSIBLE FOR INSTALLATION OF FLAT
SCREEN TV PROVIDED BY HOMEOWNER
G.C. SHALL BE RESPONSIBLE FOR PURCHASE & INSTALLATION
OF ALL CROWN MOLDINGS AS SELECTED BY HOMEOWNER
PREP, REPAIR & REFINISHING EXIST OAK FLOORING
PURCHASE & INSTALL HVAC SYSTEM AS AGREED TO BY
HOMEOWNER
TOWN ZONING REQUIREMENTS
ZONE:
SETBACKS
FRONT
ALLOWED
15 MIN
RA-5
EXISTING
PROPOSED
LOT SIZE
5,000 MIN
4452 SQFT
6.0
ZONING DATA
MAX BUILDING
COVERAGE SQFT / %
40%
32.08%
3.36%
SETBACKS (FT)
SIDE
8 / 20 MIN
9.9/21.15
REAR
35 MIN
N/A
6.0 TO EXIST
N/A
9.9/21.15
7.3 TO ENTRY
V-1
ZONING VIEWS OF HOUSE
JOIST TO SILL OR GIRDER, TOE NAIL
3-8d
DESCRIPTION OF BUILDING ELEMENTS
NUMBER & TYPE OF FASTENER
a, b, c, d
SPACING OF FASTENERS
-
1"x6" SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL
-
-
2-8d
2 STAPLES, 1-3/4
-
2" SUBFLOOR TO JOIST OR GIRDER, BLIND & FACE NAIL
2-16d
16" O.C.
16d
SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL
-
2-16d
TOP OR SOLE PLATE TO STUD, END NAIL
-
3-8d OR 2-16d
STUD TO SOLE PLATE, TOE NAIL
10d
DOUBLE STUDS, FACE NAIL
24" O.C.
24" O.C.
10d
DOUBLE TOP PLATES, FACE NAIL
SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS
3-16d
16" O.C.
-
8-16d
DOUBLE TOP PLATES, MINIMUM 48-INCH OFFSET OF END JOINTS, FACE
NAIL IN LAPPED AREA
-
3-8d
BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL
8d
RIM JOIST TO TOP PLATE, TOE NAIL
6" O.C.
-
2-10d
TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL
16" O.C. ALONG EACH EDGE
16d
BUILT-UP HEADER, TWO PIECES WITH 1
2" SPACER
16" O.C. ALONG EACH EDGE
16d
CONTINUED HEADER, TWO PIECES
CEILING JOISTS TO PLATE, TOE NAIL
3-8d
-
-
4-8d
CONTINUOUS HEADER TO STUD, TOE NAIL
3-10d
CEILING JOIST, LAPS OVER PARTITIONS, FACE NAIL
-
3-10d
CEILING JOIST TO PARALELL RAFTERS, FACE NAIL
-
2-16d
RAFTER TO PLATE, TOE NAIL
-
2-8d
2 STAPLES, 1-3/4
1" BRACE TO EACH STUD AND PLATE, FACE NAIL
-
-
-
-
2-8d
2 STAPLES, 1-3/4
1"x6" SHEATHING TO EACH BEARING, FACE NAIL
-
-
2-8d
3 STAPLES, 1-3/4
1"x8" SHEATHING TO EACH BEARING, FACE NAIL
3-8d
4 STAPLES, 1-3/4
WIDER THAN 1"x8" SHEATHING TO EACH BEARING, FACE NAIL
-
-
10d
BUILT-UP CORNER STUDS
24" O.C.
10d
BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS
NAIL EACH LAYER AS FOLLOWS:
32" O.C. AT TOP AND BOTTOM AND
STAGGERED. TWO NAILS AT ENDS
AND AT EACH SPLICE.
AT EACH BEARING
2-16d
2" PLANKS
4-16d
3-16d
ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS:
TOE NAIL
FACE NAIL
-
-
-
3-8d
RAFTER TIES TO RAFTERS, FACE
WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND WALL SHEATHING TO FRAMING, AND PARTICLEBOARD WALL SHEATHING TO FRAMING
12g
16 - 1
6d COMMON NAIL (SUBFLOOR, WALL)
8d COMMON NAIL (ROOF)f
12g
8d COMMON NAIL
32 - 1
10d COMMON NAIL OR 8d DEFORMED NAIL
1 1
8 - 1 1
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1)
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1) continued
DESCRIPTION OF BUILDING MATERIALS
2" REGULAR CELLULOSIC FIBERBOARD
SHEATHING
DESCRIPTION OF FASTENERS
b, c, d, e
1 1
2 GALVANIZED ROOFING NAIL 6d
COMMON NAIL STAPLE 16 GA., 1 1
LONG
SPACING OF FASTENERS
INTERMEDIATE SUPPORTS (INCHES) c, e
OTHER WALL SHEATHING h
2 STRUCTURAL CELLULOSIC FIBERBOARD
SHEATHING
1 1
2 GALVANIZED ROOFING NAIL 8d
COMMON NAIL STAPLE 16 GA., 1 1
LONG
32 STRUCTURAL CELLULOSIC FIBERBOARD
SHEATHING
1 3
4 GALVANIZED ROOFING NAIL 8d
COMMON NAIL STAPLE 16 GA., 1 3
LONG
2 GYPSUM SHEATHING
1 1
2 GALVANIZED ROOFING NAIL; 6d
COMMON NAIL; STAPLE
GALVANIZED, 1 1
2 LONG; 1 1
SCREWS, TYPE W OR S
8 GYPSUM SHEATHING
1 3
4 GALVANIZED ROOFING NAIL; 8d
COMMON NAIL; STAPLE
GALVANIZED, 1 5
8 LONG; 1 5
SCREWS, TYPE W OR S
WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING
4 AND LESS
6d DEFORMED NAIL OR 8d COMMON
NAIL
8 - 1
8d COMMON NAIL OR 8d DEFORMED
NAIL
1 1
8 - 1 1
10d COMMON NAIL OR 8d
DEFORMED NAIL
EDGES (INCHES) i
FOR SI: 1 INCH = 25.4mm, 1 FOOT = 304.8mm, 1 MILE PER HOUR = 1.609km/h
a.
ALL NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE
MINIMUM AVERAGE BENDING YIELD STRENGTHS AS FOLLOWS: 80ksi (551Mpa) FOR SHANK DIAMETER OF 0.192" (20d COMMON NAIL), 90ksi (620Mpa) FOR SHANK DIAMETERS LARGER
THAN 0.142" BUT NOT LARGER THAN 0.177", AND 100ksi (689Mpa) FOR SHANK DIAMETERS OF 0.142" OR LESS.
STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7
16 INCH ON DIAMETER CROWN WIDTH.
b.
NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER.
c.
4-FOOT-BY-8-FOOT OR 4-FOOT-BY-9-FOOT PANELS SHALL BE APPLIED VERTICALLY.
d.
SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(1).
e.
FOR REGIONS HAVING BASIC WIND SPEED OF 110mph OR GREATER, 8d DEFORMED NAILS SHALL BE USED FOR ATTACHING PLYWOOD AND WOOD STRUCTURAL PANEL ROOF
SHEATHING TO FRAMING WITHIN MINIMUM 48 INCH DISTANCE FROM GABLE END WALLS, IF MEAN ROOF HEIGHT IS MORE THAN 25 FEET, UP TO 35 FEET MAXIMUM.
f.
FOR REGIONS HAVING BASIC WIND SPEED OF 110mph OR LESS, NAILS FOR ATTACHING WOOD STRUCTURAL PANEL ROOF SHEATHING TO GABLE END WALL FRAMING SHALL BE
SPACED 6 INCHES ON CENTER. WHEN BASIC WIND SPEED IS GREATER THAN 100mph, NAILS FOR ATTACHING PANEL ROOF SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE
SPACED 6 INCHES ON CENTER FOR MINIMUM 48 INCH DISTANCE FROM RIDGES, EAVES AND GABLE END WALLS; AND 4 INCHES ON CENTER TO GABLE END WALL FRAMING.
g.
GYPSUM SHEATHING SHALL CONFORM TO ASTM C 79 AND SHALL BE INSTALLED IN ACCORDANCE WITH GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C 208.
h.
SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND AT ALL FLOOR PERIMETERS ONLY. SPACING
OF FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND AT ALL ROOF PLANE PERIMETERS. BLOCKING OF ROOF
OR FLOOR SHEATHING PANEL EDGES PERPENDICULAR TO THE FRAMING MEMBERS SHALL NOT BE REQUIRED EXCEPT AT INTERSECTION OF ADJACENT ROOF PLANES. FLOOR
AND ROOF PERIMETER SHALL BE SUPPORTED BY FRAMING MEMBERS OR SOLID BLOCKING.
i.
1.
GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND
VERIFY LOCAL REQUIREMENTS WITH LOCAL BUILDING OFFICIALS.
2.
ALL DIMENSIONS AND CONDITIONS TO BE VERIFIED BY CONTRACTOR PRIOR
TO CONSTRUCTION AND PRIOR TO ORDERING MATERIALS.
3.
RECORD ARCHITECT / ENGINEER OR DESIGN CONSULTANTS ARE NOT TO
FIELD SUPERVISE OR INSPECT THIS PROJECT.
4.
ALL CONCRETE SHALL BE MIXED AND PLACED IN ACCORDANCE WITH THE
LATEST A.C.I. 3000 PSI MIN. AT 28 DAY TEST (A.C.I. 319-63).
5.
ALL FOUNDATIONS AND FOOTINGS SIZED FOR BEARING ON UNDISTURBED SOIL AT
MINIMUM BEARING CAPACITY OF (2) TONS PER SQ. FT. MINIMUM OF 3' COVER.
6.
ALL WOOD FRAMING , INCLUDING JOISTS, BEAMS, POSTS, STUDS ETC. TO BE
DOUGLAS FIR SPF #2 OR BETTER @ fd1200 PSI.
7.
WOOD SILLS ON SLAB TO BE (2) 2x6 CCA WOLMINIZED LUMBER W/ 1/2" DIA.
ANCHOR BOLTS 8' O.C.
8.
ALL HEADERS TO BE SUPPORTED BY CODE REQUIREMENT MIN BEARING
SUPPORT
9.
PROVIDE DOUBLE HEADER AND TRIMMERS AT ALL STAIR AND FLOOR
OPENINGS AND UNDER ALL POSTS AND PARTITIONS RUNNING PARALLEL TO
SAME.
10.
BRIDGING TO BE EITHER SOLID OR 18 GA. CROSS BRIDGING NOT EXCEEDING 8' O.C.
11.
ALL HEADERS TO BE (2) 2x10 U.O.N. ON PLAN.
12.
THE TOP AND BOTTOM OF JOISTS MAY BE NOTCHED. NOT TO EXCEED 2". NO
NOTCHING AT MIDDLE 1/3 OF SPAN.
13.
ALL STRUCTURAL WOOD TO BE KEPT BACK 2" FROM CHIMNEY.
14.
JOIST HANGERS AND OTHER METAL FASTENERS TO BE SIMPSON OR EQUAL.
15.
ALL CONCRETE HAUNCH FOOTINGS TO HAVE (2) #5 REBAR REINFORCING RODS
(U.O.N.).
16.
THE EXTERIOR SURFACE OF ALL FOUNDATION WALLS BELOW GRADE
(EXCLUDING SLABS) SHALL BE DAMPROOFED W/ AN ELASTIC COAL TAR BASE.
17.
NOT USED
18.
PROVIDE COMBUSTION AIR VENTS AS PER N.Y.S. ENERGY CODE.
19.
FOR ALL POURED CONCRETE SLABS, PROVIDE 6x6 10/10 WWF OVER 6 MIL
POLYETHYLENE VAPOR BARRIER OVER 6" WELL COMPACTED FILL.
20.
AT LEAST (1) SINGLE STATION SMOKE DETECTING ALARM DEVICE INSTALLED IN
CONFORMITY W/ SECTION R317 IN EACH SLEEPING ROOM AND OUTSIDE EACH
SLEEPING ROOM AREA AND ON EACH STORY - INTERCONNECTED.
21.
NOT USED
22.
GLAZING IN DOORS, SHOWER DOORS AND ENCLOSURES SHALL BE SIZED AND
CONSTRUCTED OF MATERIALS AS TO MINIMIZE THE POSSIBILITY OF INJURY
TO PERSONS IN THE EVENT THAT THE GLAZING IS BROKEN OR DAMAGED.
23.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE W/ THE 2025 NYS RESIDENTIAL
BUILDING CODE AND THE N.Y.S. ENERGY CODE.
24.
ALL PLUMBING FIXTURES SHALL BE INDIVIDUALLY TRAPPED AND VENTED AS
REQUIRED BY THE N.Y.S. CODE. CAST IRON PIPE SHALL CONFORM W/ LOCAL
CODE REQUIREMENTS AND HAVE APPROVED CLEAN OUTS AN JOINTS.
25.
ALL HEATING AND COOLING DESIGNS SHALL CONFORM W/ A.S.H.R.A.E.
26.
ELECTRIC WORK TO BE IN ACCORDANCE W/ N.E.C. AND TO BE CERTIFIED BY
THE BOARD OF FIRE UNDERWRITERS.
27.
NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALE.
28.
ROOF RAFTERS AND CRAWL SPACES TO BE VENTED AS PER N.Y.S. CODE.
29.
ALL STAIRS SHALL HAVE HANDRAILS IN ACCORDANCE W/ 2025 NYS
RESIDENTIAL BUILDING CODE
30.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE AND COMPLY WITH 2025 NYS
RESIDENTIAL BUILDING CODE
GENERAL NOTES
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILE FOR AND OBTAIN ALL
REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL GOVERNING
AGENCIES HAVING JURISDICTION OVER THIS PROJECT.
31.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH THE
RESIDENTIAL CODE OF NEW YORK STATE AND ALL OTHER APPLICABLE
CODES, LAWS, RULES AND REGULATIONS IN THE CONSTRUCTION OF THIS
PROJECT.
32.
ALL PLUMBING WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW
YORK STATE AND ALL OTHER APPLICABLE CODES, LAWS, RULES AND
REGULATIONS AND HEALTH DEPARTMENT REQUIREMENTS.
33.
HEATING AND AIR CONDITIONING REQUIREMENTS SHALL BE COORDINATED WITH THE
OWNER'S H.V.A.C. CONTRACTOR PRIOR TO COMMENCING ANY WORK.
34.
ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS AND WIRING SHALL BE U.I.
CERTIFIED AND INSTALLED IN COMPLIANCE WITH WITH ALL APPLICABLE
ELECTRICAL CODES.
35.
THE CONTRACTOR SHALL RELOCATE ALL EXISTING ELECTRIC, TELEPHONE,
ANTENNA AND CABLE T.V. SERVICE WIRING AS REQUIRED.
36.
ALLOW A MINIMUM OF 18' BETWEEN BOTTOM OF FLOOR JOIST AND TOP OF
SCREED COAT OR PROVIDE CCA LUMBER.
37.
FLOOR JOISTS SHALL BE DOUBLED BENEATH ALL PARALLEL PARTITIONS.
38.
ALL INTERIOR DOORS ARE TO COMPLY WITH THE 2025 NYS RESIDENTIAL
BUILDING CODE
39.
WINDOWS AND DOORS SHALL BE PROPERLY FLASHED AT HEADS AND
PROPERLY SEALED AND WEATHER-STRIPPED.
40.
ALL GYPSUM SHALL BE TAPED AND SPACKLED (3) COATS READY FOR PAINT.
2" INCH SHEETROCK FOR ALL WALLS AND CEILINGS. 5
8" INCH TYPE "X" FOR ALL
GARAGE AND MECHANICAL ROOMS. 1
2" INCH M/R GREENBOARD FOR ALL
BATHROOMS.
41.
ALL FINISHES SHALL BE AS DIRECTED BY OWNER.
42.
ALL MICROLAM LUMBER IS TO BE MANUFACTURED BY "TRU JOIST CORP." P.O.
BOX 60 BOISE IDAHO 83707 OR APPROVED EQUAL.
43.
ALL CONCRETE TO BE 3000 PSI. 28 DAY TEST. PROVIDE 1
2" INCH DIAMETER
ANCHOR BOLTS SPACED A MAXIMUM OF 6'-0" O.C. ANCHOR BOLTS SHALL
ALSO BE LOCATED WITHIN 12' FROM THE ENDS OF EACH PLATE SECTION
EXCEPTION FOUNDATION ANCHOR STRAPS, SPACED AS REQUIRED TO
PROVIDE EQUIVALENT ANCHORAGE TO 1
2" INCH DIAMETER ANCHOR BOLTS.
44.
NO CONSTRUCTION OR DEMOLITION SHALL COMMENCE PRIOR TO THE
ISSUANCE OF THE BUILDING PERMIT.
45.
THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE AND
INSURANCE CERTIFICATES.
46.
THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO SAFE
GUARD THE EXISTING RESIDENCE AND CONTENTS AGAINST DAMAGE FROM
THE ELEMENTS DURING CONSTRUCTION.
47.
THE CONTRACTOR SHALL REPAIR ALL EXISTING CONDITIONS DAMAGED DUE
TO THE EXECUTION OF THIS WORK TO ITS ORIGINAL CONDITION.
48.
THE DRAWINGS ARE NOT TO BE SCALED - FOLOW DIMENSIONS ONLY.49.
NO CHANGE WILL BE PERMITTED WITHOUT PRIOR WRITTEN NOTIFICATION OF AN
APPROVAL OF THE ARCHITECT/ENGINEER OF RECORD.
50.
CONTRACTOR SHALL PROVIDE THE OWNER WITH A CERTIFICATE OF OCCUPANC
AND AN ELECTRICAL CERTIFICATE FROM AN APPROVED AGENCY UPON
COMPLETION OF THIS PROJECT.
51.
"TECO" DETAILS SHOWN TO COMPLY WITH THE 2025 NYS RESIDENTIAL BUILDING
CODE
52.
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
GENERAL NOTES & DETAILS
SCALE:
N.T.S
A-2
FASTENER SCHEDULE
SCALE:
N.T.S
A-2
GENERAL NOTES
A-2
9/01/2025
REMOVE WALL AS REQ'D
TO ALLOW NEW WINDOW
TO BE INSTALLED
REMOVE TILE & SETTING
BED DOWN TO
SUBFLOOR & PREP FOR
NEW CONST
REMOVE NIB WALL
REMOVE NIB WALL
REMOVE EXTERIOR WALL
REMOVE EXT DOOR
REMOVE LOWEST ROOF
IN ITS ENTIRETY & ALL
ASSOC CONST
ALL BLUESTONE STEPS
TO BE LIFTED & SET
ASIDE AS DIRECTED BY
HOMEOWNER
REMOVE EXIST SIDING IN AREAS
THAT WILL RECEIVE NEW GYP
BD. FINISH (INDOOR SPACES)
WINDOW TO BE REMOVED AND
SAVED FOR REUSE
N
SUNROOM
OFFICE
STORAGE
(2) 2X10 HEADER
NEW WALLS TO BE 2X4 FRAMING 16"O.C.
FILLED SOLID W/ CLOSED CELL INSULATION
INSIDE & OUTSIDE FACES TO ALIGN W/
EXIST CONSTRUCTION
INFILL OLD
WINDOW LOCATION
FINISH FACES TO
ALIGN
6X6 PT. POST
4" MIN THK SLAB - SLOPE END
TO ALIGN W/ DRIVEWAY - SLAB
TO BE 2" BELOW INTERIOR
FINISH FLOOR ELEV
5'-3"
3'-8"
4'-0"
6'-0"
EXIST
EXIST
EXIST
EXIST
RELOCATED
3'-4"
3'-4"
(2) 2X10 HEADER
EXTEND EXIST WD FLR
OVER NEW CONST
INTERIOR WALL TO
RECEIVE NEW GYP. BD.
FINISH
EXTERIOR WALL TO
RECEIVE CEDAR SIDING
TO MATCH EXIST HOUSE
SLAB TO ALIGN
W/ DRIVEWAY
(2) 2X6 HEADER
N
SUNROOM
OFFICE
STORAGE
4'-0"
6'-0"
1'-3"
1'-0"
6" MIN THK SLAB TO REST ON 6"
GRAVEL & COMPACTED SOIL
UNDER LANDING TO BE
COMPACTED AS REQ'D PRIOR
TO POURING TOP SLAB
PROVIDE COMPRESSIBLE
FILLER & COPPER FLASHING
BETWEEN LANDING & HOUSE
12X12 FOOTING FOR POST TO
42" BELOW GRADE
EXIST CRAWL SPACE TO
REMAIN
6" FOOTING DOWN TO
42" BELOW GRADE
UNDER LANDING TO BE
COMPACTED AS REQ'D PRIOR
TO POURING TOP SLAB
N
CONSTRUCTION PLANS
CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL REQUIRED ITEMS FROM
THE CEILING AS REQ'D TO COMPLETE THE ENTIRE PROJECT.
ALL OPENINGS DUE TO REMOVAL OF EXISTING ELECTRICAL OUTLETS, SWITCHES,
ETC., AND MECHANICAL ITEMS SHALL BE PATCHED AND REPAIRED TO MATCH
EXISTING FINISHES AND/OR NEW FINISHES.
9.
CONTRACTOR SHALL ALSO SCHEDULE AND COORDINATE ALL REQUIRED TOWN
INSPECTIONS.
CONTRACTOR SHALL OBTAIN THE ARCHITECT'S GUIDANCE WITH RESPECT TO
INTERPRETATION OR DESIGN INTENT OF DESIGN DOCUMENTS. NO ASSUMPTIONS
SHALL BE MADE BY THE CONTRACTOR.
CONTRACTOR SHALL IMMEDIATELY NOTIFY AND BRING TO THE ATTENTION OF THE
ARCHITECT ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR
CONFLICTS CONTAINED IN OR ARISING AS A RESULT OF IMPLEMENTING THE
CONTRACT DOCUMENTS.
ALL CONTRACTORS SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT THE JOB
SITE. ANY SUBSTITUTIONS OR CHANGES SHALL BE APPROVED IN WRITING BY THE
ARCHITECT BEFORE COMMENCING WORK.
THOSE ITEMS AND TASKS NOT NOTED BUT IMPLIED AS NECESSARY FOR
COMPLETION OF THE PROJECT SHALL BE CONSIDERED PART OF THE CONTRACT.
PROJECT IS COMPLETE HABITABLE SPACE.
10.
11.
12.
13.
14.
A-3
EXISTING DOOR, FRAME & HARDWARE TO BE REMOVED
DEMOLITION LEGEND
EXIST. CONSTRUCTION TO REMAIN
1.
2.
3.
4.
5.
6.
7.
EXISTING CONSTRUCTION TO BE REMOVED
PRIOR TO THE DEMOLITION OF THOSE ITEMS WHICH HAVE UTILITY CONNECTIONS
(WATER, GAS, ELECTRICITY, STEAM, ETC.) THE CONTRACTOR SHALL ARRANGE
WITH THE OWNER TO LOCATE SHUTOFF VALVES, PANEL BOXES AND OTHER
CONTROL ELEMENTS, SO THAT WATER DAMAGE AND OTHER POTENTIALLY
INCONVENIENT OR DANGEROUS SITUATIONS ARE VOIDED.
PATCH, FILL AND REPAIR ALL SURFACES DISTURBED, CUT, DAMAGED, IN NEED OF
REPAIR OR MADE IMPERFECT BY ALTERATIONS OR REMOVAL WORK AND AS
REQUIRED TO PREPARE SURFACES FOR NEW MATERIALS AND ARRANGEMENTS.
KEP AL ADJOINING AREAS CLEAN AND FRE OF DEBRIS OR CONSTRUCTION
MATERIALS DURING WORKING HOURS, AND PROVIDE SAFE SITE CONDITIONS.
PRIOR TO THE START OF DEMOLITION, THE CONTRACTOR SHALL CALL TO THE
ATTENTION OF THE OWNER: ANY DAMAGE, CRACKS OR OTHER IMPERFECTIONS IN
THE WORK ADJACENT TO DEMOLITION AREAS.
BEFORE STARTING WORK, MAKE A THOROUGH EXAMINATION OF THOSE PORTIONS
OF THE STRUCTURE IN WHICH THE WORK IS TO BE PERFORMED. CHECK ALL THE
WORK ADJOINING OR AT UNDERLYING LOCATIONS. REPORT TO THE ARCHITECT
ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH OR OTHERWISE AFFECT
OR PREVENT THE PROPER EXECUTION AND COMPLETION OF THE WORK. DO NOT
START THE WORK UNTIL SUCH CONDITIONS HAVE BEEN EXAMINED AND A COURSE
OF ACTIONS MUTUALLY AGREED UPON.
ALL DEMOLITION AND REMOVAL WORK SHALL BE COMPLETED AS INDICATED AND
NOTED ON THE DRAWINGS AND AS SPECIFIED.
8.
DEMOLITION NOTES
THE PROJECT SHALL BE GOVERNED IN ANY AND ALL RESPECTS BY THE CURRENT
EDITION OF THE THE 2025 NYS RESIDENTIAL CODE
4/16/2024
AS NOTED
SCALE:
1/4"=1'-0"
A-3
DEMOLITION PLAN
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
G.C. IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT AND SHORING OF
EXISTING CEILINGS, PARTITIONS, ETC. DURING DEMOLITION AND RENOVATION.
15.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE COLLECTION OF ALL
ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS NOT INDICATED
AS ISSUED FOR CONSTRUCTION AND FOR DISTRIBUTION TO ALL SUB
CONTRACTORS & CONSULTANTS ARCHITECTURAL, STRUCTURAL, AND
MECHANICAL DRAWINGS ISSUED FOR CONSTRUCTION, THE MOST CURRENT
REVISED SET.
16.
17. PROTECT EXIST FLOORS FOR REUSE
COORD ALL POWER & LIGHTING LOCATIONS & TYPE W/ HOME OWNER
CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMP. DUST AND DEBRIS
PROTECTION BETWEEN AREAS OF CONSTRUCTION AND AREAS IN WHICH NO
WORK IS TAKING PLACE. LOCATION OF SUCH PROTECTION SHALL BE VERIFIED
WITH OWNER PRIOR TO COMMENCING WORK AND IN CO-ORDIN. WITH
PROGRESSION OF WORK SCHEDULE. HE SHALL PERFORM THE WORK IN A
MANNER THAT WILL AVOID HAZARDS TO PERSONS IN ADJACENT AREAS AND THAT
WON'T INTERFERE WITH WORK OR PASSAGE TO ANY OF THESE AREAS.
CONTRACTOR IS TO VERIFY ALL CONDITIONS AND NOTIFY ARCHITECT & HOME
OWNER OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK.
AL PLUMBING & POWER REQUIREMENTS FOR
CONVENIENCE & EQUIPMENT BEING
INSTALED ARE TO FOLOW THE 2025 NYS RESIDENTIAL BUILDING CODE
FINISHES THAT ARE DISTURBED BY DEMOLITION SHAL BE PATCHED TO MATCH EXISTING.
CONTRACT DRAWINGS ARE NOT INTENDED TO REPRESENT EXACT DIMENSIONS.
FIELD DIMENSIONS ARE THE RESPONSIBILITY OF THIS CONTRACTOR FOR ALL
PHASES INCLUDING BIDDING, FABRICATION, COORDINATION AND CONSTRUCTION.
ALL DIMENSIONS TO BE APPROVED BY ARCHITECT / HOME OWNER
CONTRACTOR TO REMOVE ANY STRAY PAINT, DIRT, OR STAINS INCURED DURING THE
CONSTRUCTION PROCES. CONTRACTOR SHAL BE RESPONSIBLE FOR REMOVING AL
TEMPORARY EQUIPMENT COVERINGS USED DURING CONSTRUCTION AND HE SHAL
ALSO BE RESPONSIBLE FOR THE REMOVING OF HIS TRASH OF OF THE JOB SITE DAILY
ALL WALL BASE & TRIM TO MATCH EXIST AS DIRECTED BY THE HOME OWNER
1.
2.
3.
4.
6.
7.
8.
16.
5.
ALL WALL INFILL LOCATIONS CONSTRUCTION AS TO BE 2x CONSTRUCTION TYPE TO
ALLOW FINISH SURFACES TO ALIGN W./ EXISTING FRAMING
12.
AL HEADERS TO BE FULY ADHERED TOGETHER AND NAILED W/ 10P NAILS ON 6" CENTERS
13.
AL NEW EXTERIOR WALS TO BE 2x6 STUDS 16"O.C. MAX W/ 1/2" GYP. BD. ON INSIDE FACE
& 1/2" CDX PLY WD ON THE EXTERIOR W/ TYVEK TYPE HOUSE WRAP (AL SEAMS TAPED),
R-19 FACED BAT INSULATION CAVITY & 1-1/2"" R-7.5 CONT RIGID INSUL ON EXTERIOR W/
SIDING TO MATCH EXISTING
14.
AL NEW INTERIOR WALS TO BE 2x4 STUDS 16"O.C. MAX W/ 1/2" GYP. BD. ON EA FACE &
SOUND BAT INSULATION
15.
AL WORK ASOCIATED WITH THE RECONFIGURATION OF THE PLUMBING INCLUDING
THE POSIBLE DEMOLITION AND REPAIR OF THE CEILING BELOW IT IS THE
RESPONSIBILITY OF THE GC
9.
**
HOMEOWNER TO PROVIDE TUB & FAUCET. AL OTHER SUPLIES REQUIRED FOR A
COMPLETE INSTALATION / PROJECT ARE THE RESPONSIBILITY OF THE GC
10.
AL WALS & CEILINGS ARE TO BE PAINTED W/ 2 COLOR COATS AND PRIMER COAT
COLOR AS SELECTED BY HOMEOWNER
11.
CONSTRUCTION ITEMS
HOME OWNER IS RESPONSIBLE FOR PURCHASE OF VANITY, SINK
FAUCET & TOILET. INSTALLATION AND ITEMS REQUIRED FOR
FUNCTION ARE GC RESPONSIBILITY
ALL GENERAL LIGHTING TO BE LED DOWNLIGHTS BY GC.
HOMEOWNER MAY ADD DECORATIVE LIGHTING FIXTURE (BY
OWNER) INSTALLED BY GC
ALL REQUIRED POWER RELOCATIONS FOR EXISTING ITEMS
IMPACTED BY THIS CONSTRUCTION ARE TO BE PART OF THE BASE
CONTRACT IE: ATS SWITCH, INCOMING SERVICE A/C POWER AND
ANY OTHER ITEM IMPACTED
CONSTRUCTION NOTES
SCALE:
1/4"=1'-0"
A-3
FOUNDATION PLAN
SCALE:
1/4"=1'-0"
A-3
CONSTRUCTION PLAN
DN
DN
DN
LINE OF ICE
SHIELD
2X8 RAFTERS
16"O.C. MAX
2X8 RAFTERS
16"O.C. MAX
EXIST RAFTERS
TO REMAIN
EXIST RAFTERS
TO REMAIN
2X12 NAIL FLAT
TO EXIST ROOF
SHEATHING
3'-0"
3'-0"
3'-0"
1'-6"
1'-6"
3'-0"
1'-6"
1'-6"
1'-6"
NEW ROOF PITCH
TO MATCH EXIST
ROOF PITCH
LIMIT OF EXIST
ROOF
3'-0"
1'-6"
1'-6"
LINE OF ICE
SHIELD
LINE OF ICE
SHIELD
PROVIDE ICE SHIELD
UNDER ENTIRETY OF
STANDING SEAM ROOF
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
5" GUTTER TO MATCH
EXIST HOUSE STYLE
NOTE: TIE NEW
DOWNSPOUTS (3) INTO
EXIST GUTTER
DRAINAGE LINE
RAFTERS TO LAN
ON 2X12 ON ROOF
EXIST ROOF FLASHING
UP SIDE OF HOUSE TO
REMAIN & BE REUSED
A-5
2X6 RAFTERS
16"O.C. MAX
(2) 2X10 ridge
board
2'-0"
N
PROVIDE (3) LEADERS TIED
INTO EXIST GUTTER DRAINAGE
LINE
1'-0"
3'-6"
NEW CEDAR SIDING TO MATCH
EXIST - PAINT AS DIRECTED BY
HOMEOWNER
5" GUTTERS TO MATCH
EXIST HOUSE STYLE
1'-8"
2X6 RAFTERS
16"O.C. MAX
2X8 RAFTERS
16"O.C. MAX
NEW (2) 2X10 ridge board TO
EXTEND 32" MIN OVERLAP TO
EXIST ridge board & EXTEND TO
EXIST ROOF OVER OFFICE
PROPOSED
EXIST
2X10 RAFTERS
16"O.C. MAX
2X8 RAFTERS
16"O.C. MAX
2X6 RAFTERS
16"O.C. MAX UNDER
STANDING SEAM
ROOF
PROPOSED
EXIST
2X8 RAFTERS
16"O.C. MAX
NEW FASCIA TO
ALIGN W/ EXIST
PROVIDE NEW 5"
GUTTER TO MATCH
EXIST STYLE
EXIST DOOR TO
REMAIN
RELOCATED
WINDOW
(2) 2X10
HEADER
PROVIDE (2) JACK
STUDS UNDER EA SIDE
EXIST
WINDOW TO
REMAIN
1'-0"
3'-6"
ASPHALT SHINGLES AS
SELECTED BY HOMEOWNER
EXIST ROOF BEYOND
STANDING SEAM METAL
ROOF
1X AZAK TYPE FASCIA
EXIST SIDING BEYOND
6X6 P.T. POST
6X6 POST
LINE OF EXIST
HOUSE
12X12 POST TO 42" BELOW
GRADE
4" GRAVEL BASE
COMPRESSIBLE
FILLER BETWEEN
HOUSE & LANDING
ROOF PLAN,
ELEVATIONS & DETAILS
A-4
4/16/2024
AS NOTED
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
SCALE:
1/4"=1'-0"
A-4
ROOF PLAN
SCALE:
1/4"=1'-0"
A-4
NORTH ELEVATION
SCALE:
1/4"=1'-0"
A-4
SOUTH ELEVATION
SCALE:
1/4"=1'-0"
A-4
WEST ELEVATION
SCALE:
1/4"=1'-0"
A-4
EAST ELEVATION
EXIST LIGHTS &
POWER TO REMAIN
EXIST LIGHTS &
POWER TO REMAIN
A
S S
A B
SUNROOM
OFFICE
STORAGE
B
B
B
B
B
B
S
B3
7'-0"
3'-8"
EQ
EQ
3'-8"
EQ
EQ
1'-0"
1'-0"
5'-0"
1'-0"
N
1'-0"
3'-6"
2X6 CEILING FRAMING
16"O.C. MAX
2" GYP. BD.
R-49 FACED BATT
INSULATION
OPENING BEYOND
EXIST BACK WALL TO
REMAIN
2X8 RAFTERS
16"O.C. MAX
PROVIDE RAFTER
TO WALL TIES @ EA
RAFTER
(2) 2X10 ridge board TO BE FULLY ADHERED & STRUCTURALLY
SCREWED 16"O.C. W/ 1
2" TIMBER TEK TYPE SCREWS
PROVIDE RAFTER HANGERS
@ EA. RAFTER
PROVIDE RIDGE VENT W/
CAP SHINGLES
2X8 RAFTERS 16"O.C. MAX W/ CDX
SHEATHING, SYNTHETIC ROOF FELT &
ASPHALT SHINGLES TO MATCH EXIST HOUSE
STANDING SEAM METAL ROOF AS
SELECTED BY HOMEOWNER
2X6 RAFTERS 16"O.C. MAX
2X6 CLG FRAMING
16"O.C. MAX
(2) 2X8 HEADER
INSULATED EXT DOOR AS
SELECTED BY HOMEOWNER
NEW SIDING TO
MATCH EXIST AS
REQ'D
6"
GALV. BASE CONNECTOR
1/2" "J" BOLT
6"
6" CONCRETE LANDING TO
BE 2" BELOW FINISH FLOOR
ALIGN W/
DRIVEWAY
4'-0"
6 MIL VAPOR
BARRIER
EXIST SOIL TO REMAIN-
COMPRESS AS
NEEDED
4" GRAVEL
12X12 FOOTING UNDER
POST TO 42" BELOW GRADE
6 MIL VAPOR
BARRIER
EXIST SOIL TO REMAIN-
COMPRESS AS
NEEDED
4" GRAVEL
6" W CONC FOUNDATION TO
42" BELOW GRADE
2 LAYERS 3" R-5 / INCH
RIGID INSULATION
UNDER SLAB
4" CONC SLAB -
W/ 6X6 WWF
6"
1'-2"
COMPRESSIBLE
FILLER
PROVIDE COPPER FLASHING
- EXTEND 6" UNDER FLOOR
@ 14" DOWN FACE OF
FOUNDATION
EXIST STRUCTURE
TO REMAIN
PROVIDE CLOSED CELL
SPRAY INSULATION
UNDER EXIST FLOOR
STRUCTURE - R-30 MIN
LINE OF EXIST GRADE
5" GUTTER TO MATCH
EXIST HOUSE GUTTER
STYLE
5" GUTTER TO MATCH
EXIST HOUSE GUTTER
STYLE
NOTE: ALL EXTERIOR WALLS
TO BE BUILT W/ 2X6 WD
STUDS 16"O.C. MAX W/ R-21
FACED BATT INSULATION W/
1" R-5 CONT INSULATION
6X6 P.T. POST
(2) 2X6 HEADER
6"
SIMPSON BC6X
POST CAP G-90
16.
17.
15.
18.
1.
2.
3.
4.
7.
5.
6.
8.
9.
10.
11.
12.
13.
THE SPACE IS EQUIPPED WITH A HARDWIRED BATTERY BACKED UP SMOKE
DETECTOR.
ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICIAN
ALL OF THE EXISTING CONSTRUCTION IN THE BASEMENT IS STRUCTURALLY SOUND
THE SPACE IS TO BE EQUIPPED WITH A HARDWIRED BATTERY BACKED UP CO2
DETECTOR.
ALL FIXTURES AND FINISHES ARE TO BE SUPPLIED BY OWNER & INSTALLED BY
G.C. U.O.N.
AL MATERIAL USED SHAL BE NEW, BEST OF THEIR RESPECTIVE KINDS, FRE FROM
DEFECTS AND CONFORM TO THE REQUIREMENTS OF AL LOCAL, STATE, AND NATIONAL
AUTHORITIES HAVING JURISDICTION.
SUBCONTRACTORS SHALL FILE FOR PLUMBING AND ELECTRICAL PERMITS, PAY
FOR ALL FEES AND HAVE THEIR WORK INSPECTED BY STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION. CONTRACTOR SHALL SECURE ANY AND ALL
CERTIFICATES OF COMPLIANCE AND/OR INSPECTION ISSUED BY SAID AGENCIES.
ANY MODIFICATION OR CHANGE CALLED FOR BY AUTHORITIES HAVING
JURISDICTION SHALL BE MADE WITHOUT ADDITIONAL CHARGE.
ARCHITECTURAL DRAWINGS FOR PLUMBING AND ELECTRICAL ARE DIAGRAMMATIC
AND INDICATE THE GENERAL ARRANGEMENT OF THE WORK REQUIRED. EACH
CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES AS
REQUIRED TO AVOID INTERFERENCES AND INSURE PROPER INSTALLATION.
ALL SUBCONTRACTORS SHALL LAY OUT THEIR WORK IN ADVANCE SO ALL
NECESSARY ACCOMMODATIONS FOR IT CAN BE MADE AS REQUIRED.
UNNECESSARY CUTTING OF THE STRUCTURE IS TO BE AVOIDED. SHOULD A
CONTRACTOR REQUIRE CUTTING FOR THE INSTALLATION OF HIS WORK HE SHALL
COORDINATE HIS REQUIREMENTS WITH OTHER CONTRACTORS AND THE
ARCHITECT AND PAY ALL COSTS FOR SAID CUTTING, STRENGTHENING, AND ANY
PATCHING THAT MAY RESULT.
ALL WORK SHALL BE INSTALLED READILY ACCESSIBLE FOR OPERATION,
MAINTENANCE, AND REPAIRS. EQUIPMENT INSTALLED AS A PART HEREOF IS TO BE
FULLY GUARANTEED FOR ONE (1) YEAR AGAINST FAULTY PARTS AND
WORKMANSHIP FROM THE DATE OF ACCEPTANCE OR FINAL PAYMENT, WHICHEVER
COMES LATER.
ANY RIGGING AND HOISTING REQUIRED BY ANY CONTRACTOR SHALL BE DONE BY
HIM AS A NORMAL PART OF HIS INSTALLATION PROCEDURES.
ACCESSORIES NEEDED TO MAKE THE INSTALLATION OF EACH SUBCONTRACTOR
PERFECT AND COMPLETE IN ALL RESPECTS AND READY FOR OPERATION, EVEN IF
NOT PARTICULARLY CALLED FOR, SHALL BE FURNISHED, DELIVERED AND
INSTALLED HEREIN WITHOUT ADDITIONAL COST. INCLUDED HERE UNDER SHALL BE,
BUT NOT LIMITED TO, THE INCIDENTAL OR MINOR ITEMS THAT ARE NOT SHOWN OR
SPECIFIED, BUT WHICH ARE CONSIDERED AS NECESSARY FOR THE PROPER
FUNCTIONING OF THE INSTALLATION BY TRADE CUSTOM AND/OR STANDARD
PRACTICE, OR SPECIAL REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
PROVIDE AND INSTALL SMOKE DETECTORS AS PER DRAWINGS AND AS PER CODE.
WHERE OUTLETS AND SWITCHES ARE PLACE IN CABINETRY, PANELING OR
MOLDING, THE CARPENTER, NOT THE ELECTRICIAN, SHALL MAKE ALL CUTS.
UNLESS OTHERWISE NOTED, ALL WALL SWITCHES SHALL BE MOUNTED 3'-0" .FF.. TO
CENTER AND ALIGN WITH DOOR HARDWARE AT 3'-0" A.F.F.
ALL MULTIPLE SWITCH PLATE CONFIGURATIONS ARE TO BE DETERMINED.
ALL MULTI-GANG FACE PLATES SHALL BE ONE PIECE.
ALL MATERIAL, EQUIPMENT, AND FIXTURES, INCLUDING THOSE SUPPLIED BY
OWNER AND INSTALLED BY G.C., MUST BE IN COMPLIANCE WITH U.L.
PROPOSED PROJECT SHALL COMPLY WITH THE NEW YORK STATE
BUILDING CODE FOR RESIDENTIAL (2025 NYS RESIDENTIAL CODE,
NATIONAL ELECTRIC CODE 2017 OF NYS)
S
SM
CO
HARDWIRED BATTERY BACKED
-UP SMOKE DETECTOR. ALL
ARE TO BE INTERCONNECTED
HARDWIRED BATTERY
BACKED UP WALL MTD.
CARBON MONOXIDE
DETECTOR PER NYS CODE
WALL MTD. DUPLEX ELEC. OUTLET
WALL MTD. PHONE/DATA OUTLET
WALL MTD. ELEC. QUAD OUTLET
INSULATION CONTACT DOWN
LIGHT
WALL MTD. LIGHT SCONCE
WALL MTD. LIGHT SWITCH
CEILING MTD DIRECTIONAL LED DOWNLIGHT
WAL MTD LED STRIP FIXTURE. MOUNT OVER DOOR
INSIDE CLOSET
19.
NO BEDROOMS ARE ADDED AS PART OF THIS DESIGN
PLUMBING & ELECTRICAL NOTES
AL LIGHT FIXTURES TO BE SELECTED BY THE
HOMEOWNER. THIS DRAWING IS FOR REFERENCE
ONLY
**
SECTION, LIGHTING &
POWER PLAN
A-5
4/16/2024
AS NOTED
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
SCALE:
1/4"=1'-0"
A-5
LIGHTING & POWER PLAN
FIRST FLOOR
5.
4.
3.
2.
1.
ALL NEW SWITCHES ARE TO NEW DECORA TYPE
SWITCHES
ALL NEW DOWNLIGHTS ARE TO BE DIRECTIONAL
CONTRACTOR TO COORDINATE FINAL LOCATION OF
LIGHTING FIXTURES WITH OWNER BEFORE
INSTALLATION
THIS LIGHTING PLAN IS FOR REFERENCE ONLY ALL
LIGHTING LOCATIONS AND FIXTURE TYPES ARE TO
BE BY THE HOME OWNER AND INSTALLED BY G.C.
U.O.N
ALL NEW SWITCH LOCATIONS ARE TO BE
CONFIRMED IN THE FIELD WITHT THE OWNER
ALL NEW OUTLETS ARE TO BE MATCH EXISTING OUTLETS
6.
5. ALL OUTLET LOCATIONS ARE TO BE VERIFIED WITH
OWNER PRIOR TO INSTALLATION
ALL EXISTING POWER IS TO REMAIN WHERE POSSIBLE.
4.
3. CONTRACTOR SHALL INSTALL ELECTICAL DEVICES
FOLLOWING ALL APPLICABLE CODES
CONTRACTOR TO FURNISH & INSTALL LIFE SAFETY
DETECTORS AS DIRECTED BY THE NEW YORK STATE
BUILDING CODE
2.
1. ALL OUTLETS TO DECORA TYPE OUTLETS
POWER & SIGNAL NOTES
REFLECTED CEILING NOTES
RCP / POWER LEGEND
SCALE:
3/4"=1'-0"
A-5
SECTION
HUNTER PLACE
PALMER AVENUE
VIEW KEY PLAN
PROPOSED RENOVATION TO THE:
CROCKER RESIDENCE
39 PALMER AVENE
CROTON ON HUDSON NY 10520
C
LR
PROJECT NAME
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER
OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS
ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL
AFFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION
"ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
ISSUE
DATE
REVISION
ISSUED FOR BID & FILING
11/15/2025
A R C H I T E C T
3 WINDSOR ROAD
CROTON-ON-HUDSON, NEW YORK
TEL (914) 330-1802
LEWISROANEDESIGN@GMAIL.COM
L E W I S C R O A N E
DRAWING TITLE
DRAWING NUMBER
DATE
REVISED PER TOWN COMMENT
3/22/2026
ZONING VIEWS
OF HOUSE
V-1
3/30/2026
VIEW 1
VIEW 2
VIEW 3
VIEW 4
VIEW 5
VIEW 6
VIEW 9
VIEW 8
VIEW 7
Machine-extracted for search and reference — the original PDF is the authoritative version.