GENERAC SD230 230kW Diesel Genreator Spec Sheet 0K5098

agreement 7 pages
Meeting: portal event 1074 (no meeting page on file)
Agenda item: Referral from Village Board of Trustees for a Local Waterfront Revitalization Program (LWRP) Consistency review for AT&T Lease Agreement and Special Permit to co-locate a wireless facility at 1 Van Wyck Street
Agreement / contract, 7 pages. Attached to agenda item: “Referral from Village Board of Trustees for a Local Waterfront Revitalization Program (LWRP) Consistency review for AT&T Lease Agreement and Special Permit to co-locate a wireless facility at 1 Van Wyck Street”
Retrieved 2026-04-15 from the village's meeting portal. View the original PDF ↗
Also attached to this agenda item: 14652291 Croton on Hudson.Roof SA.04-01-25 14652291 Croton on Hudson Mount Analysis Report... 14652291.Croton on Hudson.Tower Analysis.04.25.2025 14652291.Croton-On-Hudson.CDS.Rev 0.06.27.2025 14652291 2191A1DMPN Croton On Hudson 6409InitialLetter... Coastal Assessment Form - AT T LWRP 2024 Updated LWRP 2024 Updated2 Short EAF Part 1 - AT T Wireless
SPEC SHEET 1 of 7 Standby Power Rating 230 kW, 288 kVA, 60 Hz Prime Power Rating* 207 kW, 259 kVA, 60 Hz *EPA Certified Prime ratings are not available in the US or its Territories. Image used for illustration purposes only Codes and Standards Not all codes and standards apply to all configura- tions. Contact factory for details. UL2200, UL6200, UL1236, UL489, UL142 CSA C22.2, ULC S601 TM BS5514 and DIN 6271 ® SAE J1349 NFPA 37, 70, 99, 110 NEC700, 701, 702, 708 NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012) Powering Ahead For over 60 years, Generac has provided innovative design and superior manufacturing. Generac provides superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally for the most reliable engines to power our generators. We choose only engines that have already been proven in heavy-duty industrial applications under adverse conditions. Generac is committed to ensuring our customers’ service support continues after their generator purchase. SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET 2 of 7 STANDARD FEATURES ENGINE SYSTEM • Oil Drain Extension • Heavy Duty Air Cleaner • Level 1 Fan and Belt Guards (Open Set Only) • Stainless Steel Flexible Exhaust Connection • Factory Filled Oil and Coolant • Radiator Duct Adapter (Open Set Only) • Critical Silencer FUEL SYSTEM • Fuel Lockoff Solenoid • Primary Fuel Filter COOLING SYSTEM • Closed Coolant Recovery System • UV/Ozone Resistant Hoses • Factory-Installed Radiator • Radiator Drain Extension • 50/50 Ethylene Glycol Antifreeze • 120 VAC Coolant Heater ELECTRICAL SYSTEM • Battery Charging Alternator • Battery Cables • Battery Tray • Rubber-Booted Engine Electrical Connections • Solenoid Activated Starter Motor ALTERNATOR SYSTEM • GENprotect™ • 12 Leads (3-Phase, Non 600V) • Class H Insulation Material • Vented Rotor • 2/3 Pitch • Skewed Stator • Auxiliary Voltage Regulator Power Winding • Permanent Magnet Excitation • Sealed Bearings • Automated Manufacturing (Winding, Insertion, Lacing, Varnishing) • Rotor Dynamically Spin Balanced • Amortisseur Winding • Full Load Capacity Alternator • Protective Thermal Switch GENERATOR SET • Internal Genset Vibration Isolation • Separation of Circuits - High/Low Voltage • Separation of Circuits - Multiple Breakers • Wrapped Exhaust Piping • Standard Factory Testing • 2 Year Extended Limited Warranty (Standby Rated Units) • 1 Year Extended Limited Warranty (Prime Rated Units) • Silencer Mounted in the Discharge Hood (Enclosed Units Only) ENCLOSURE (IF SELECTED) • Rust-Proof Fasteners with Nylon Washers to Protect Finish • High Performance Sound-Absorbing Material (Sound Attenuation Enclosures) • Gasketed Doors • Upward Facing Discharge Hoods (Radiator and Exhaust) • Stainless Steel Lift Off Door Hinges • Stainless Steel Lockable Handles • RhinoCoat™- Textured Polyester Powder Coat Paint FUEL TANKS (IF SELECTED) • UL 142/ULC S601 • Double Wall • Vents • Sloped Top • Sloped Bottom • Factory Pressure Tested - 2 psi • Rupture Basin Alarm • Fuel Level • Check Valve In Supply and Return Lines • RhinoCoat™- Textured Polyester Powder Coat Paint • Stainless Steel Hardware CONTROL SYSTEM Digital H Control Panel- Dual 4x20 Display Program Functions • Programmable Crank Limiter • 7-Day Programmable Exerciser • Special Applications Programmable Logic Controller • RS-232/485 Communications • All Phase Sensing Digital Voltage Regulator • 2-Wire Start Capability • Date/Time Fault History (Event Log) • Isochronous Governor Control • Waterproof/Sealed Connectors • Audible Alarms and Shutdowns • Not in Auto (Flashing Light) • Auto/Off/Manual Switch • E-Stop (Red Mushroom-Type) • NFPA110 Level I and II (Programmable) • Customizable Alarms, Warnings, and Events • Modbus® Protocol • Predictive Maintenance Algorithm • Sealed Boards • Password Parameter Adjustment Protection • Single Point Ground • 16 Channel Remote Trending • 0.2 msec High Speed Remote Trending • Alarm Information Automatically Annunciated on the Display Full System Status Display • Power Output (kW) • Power Factor • kW Hours, Total, and Last Run • Real/Reactive/Apparent Power • All Phase AC Voltage • All Phase Currents • Oil Pressure • Coolant Temperature • Coolant Level • Engine Speed • Battery Voltage • Frequency Alarms and Warnings • Oil Pressure • Coolant Temperature • Coolant Level • Engine Overspeed • Battery Voltage • Alarms and Warnings Time and Date Stamped • Snap Shots of Key Operation Parameters During • Alarms and Warnings • Alarms and Warnings Spelled Out (No Alarm Codes) SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET 3 of 7 CONFIGURABLE OPTIONS ENGINE SYSTEM ○Block Heater ○Oil Make-Up System ○Oil Heater ○Industrial Exhaust Silencer (Open Set Only) FUEL SYSTEM ○Flexible Fuel Lines ○Primary Fuel Filter ELECTRICAL SYSTEM ○10A UL Listed Battery Charger ○Battery Warmer ALTERNATOR SYSTEM ○Alternator Upsizing ○Anti-Condensation Heater ○Tropical Coating CIRCUIT BREAKER OPTIONS ○Main Line Circuit Breaker ○2nd Main Line Circuit Breaker ○Shunt Trip and Auxiliary Contact ○Electronic Trip Breakers GENERATOR SET ○Extended Factory Testing ○IBC Seismic Certification ○8 Position Load Center ENCLOSURE ○Weather Protected Enclosure ○Level 1 Sound Attenuated ○Level 2 Sound Attenuated ○Steel Enclosure ○Aluminum Enclosure ○Up to 200 MPH Wind Load Rating (Contact Factory for Availability) ○AC/DC Enclosure Lighting Kit ○Spring or Pad Vibration Isolators FUEL TANKS (Sizes On Last Page) ○Overfill Protection Valve ○Fuel Fill Drop Tube ○5 Gal Spill Return Hose ○Tank Risers ○Florida DEP-DERM ○Vent Extensions ○Fire Rated Fuel Hose ○8 in (203.2 mm) Fill Extension ○13 in (330.2 mm) Fill Extension CONTROL SYSTEM ○NFPA 110 Compliant 21-Light Remote Annunciator ○Remote Relay Assembly (8 or 16) ○Remote E-Stop (Break Glass-Type, Surface Mount) ○Remote E-Stop (Red Mushroom-Type, Surface Mount) ○Remote E-Stop (Red Mushroom-Type, Flush Mount) ○10A Engine Run Relay ○Ground Fault Annunciator WARRANTY ○2 Year Extended Limited Warranty ○5 Year Extended Limited Warranty ○7 Year Extended Limited Warranty ○10 Year Extended Limited Warranty ENGINEERED OPTIONS ENGINE SYSTEM ○Coolant Heater Ball Valves ○Fluid Containment Pan CONTROL SYSTEM ○Spare Inputs (x4)/Outputs (x4) ○Battery Disconnect Switch ALTERNATOR SYSTEM ○3rd Breaker System GENERATOR SET ○Special Testing ○Motorized Dampers ○Door Open Alarm Horn ○Enclosure Heaters SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET 4 of 7 APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Iveco/FPT EPA Emissions Compliance Stationary Emergency EPA Emissions Reference See Emission Data Sheet Cylinder # Type In-line Displacement - in3 (L) 530.91 (8.7) Bore - in (mm) 4.61 (117) Stroke - in (mm) 5.31 (135) Compression Ratio 16.5:1 Intake Air Method Turbocharged/Aftercooled Cylinder Head 4–Valve Piston Type Aluminum Crankshaft Type Forged Steel Engine Governing Governor Electronic Isochronous Frequency Regulation (Steady State) ±0.25% Lubrication System Oil Pump Type Gear Oil Filter Type Full-Flow Cartridge Crankcase Oil Capacity - qt (L) 29.6 (28.0) Cooling System Cooling System Type Closed Water Pump Type Pre-Lubed, Self Sealing Fan Type Pusher Fan Speed - RPM 2,538 Fan Diameter - in (mm) 30 (762) Fuel System Fuel Type Ultra Low Sulfur Diesel Fuel #2 Fuel Specifications ASTM Fuel Filtering (Microns) Fuel Inject Pump Make Electronic Fuel Pump Type Engine Driven Gear Injector Type Common Rail Engine Type Direct Injection Fuel Supply Line - in (mm) 0.5 (12.7) NPT Fuel Return Line - in (mm) 0.5 (12.7) NPT Engine Electrical System System Voltage 24 VDC Battery Charger Alternator Standard Battery Size See Battery Index 0161970SBY Battery Voltage 12 VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model K0250124Y21 Poles Field Type Revolving Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% Telephone Interference Factor (TIF) <50 Standard Excitation Permanent Magnet Excitation Bearings Single Sealed Cartridge Coupling Direct via Flexible Disc Prototype Short Circuit Test Yes Voltage Regulator Type Digital Number of Sensed Phases All Regulation Accuracy (Steady State) ±0.25% SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET 5 of 7 OPERATING DATA POWER RATINGS - DIESEL Standby Three-Phase 120/208 VAC @0.8pf 230 kW Amps: 798 Three-Phase 120/240 VAC @0.8pf 230 kW Amps: 692 Three-Phase 277/480 VAC @0.8pf 230 kW Amps: 346 Three-Phase 346/600 VAC @0.8pf 230 kW Amps: 277 MOTOR STARTING CAPABILITIES (SKVA) skVA vs. Voltage Dip 277/480 VAC 3Ø 30% 208/240 VAC 3Ø 30% K0250124Y21 K0250124Y21 K0300124Y21 K0300124Y21 K0350124Y21 1,190 K0350124Y21 FUEL CONSUMPTION RATES* Diesel - gph (Lph) Fuel Pump Lift - ft (m) Percent Load Standby 3 (1) 25% 5.1 (19.3) 50% 9.6 (36.3) Total Fuel Pump Flow (Combustion + Return) - gph (Lph) 75% 13.7 (51.9) 26 (98) 100% 17.0 (64.3) *Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Standby Coolant Flow gpm (Lpm) 63.3 (240.0) Coolant System Capacity gal (L) 12.7 (49.2) Heat Rejection to Coolant BTU/hr (kW) 626,756 (184) Inlet Air cfm (m³/hr) 8,872 (251) Maximum Operating Ambient Temperature °F (°C) 120 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199280SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power - cfm (m³/min) 660 (18.7) ENGINE Standby Rated Engine Speed RPM 1,800 Horsepower at Rated kW** hp Piston Speed ft/min (m/min) 1,593 (486) BMEP psi (kPa) 336 (2,289) **Refer to “Emissions Data Sheet” for maximu305 (2,103)m bHP for EPA and SCAQMD permitting purposes. EXHAUST Standby Exhaust Flow (Rated Output) cfm (m³/min) 1,424 (40.4) Maximum Allowable Backpressure inHg (kPa) 1.5 (5.1) Exhaust Temperature (Rated Output) °F (°C) 955 (513) Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards. Standby - See Bulletin 0187500SSB Prime - See Bulletin 0187510SSB SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET 6 of 7 DIMENSIONS AND WEIGHTS* L W H L W H COMPACT VARIANT Run Time - Hours Usable Capacity - gal (L) L x W x H - in (mm) Weight - lbs (kg) No Tank - 128.0 (3,250) x 53.4 (1,357) x 57.5 (1,460) 4,325 - 5,108 (1,926 - 2,317) 153 (579) 128.0 (3,250) x 53.4 (1,357) x 70.5 (1,790) 5,330 - 6,113 (2,382 - 2,773) (1,408) 128.0 (3,250) x 53.4 (1,357) x 82.5 (2,095) 5,752 - 6,535 (2,573 - 2,964) (2,230) 128.0 (3,250) x 53.4 (1,357) x 94.5 (2,400) 6,169 - 6,952 (2,762 - 3,153) (1,893) 172.6 (4,384) x 53.4 (1,357) x 81.5 (2,070) 6,388 - 7,171 (2,696 - 3,087) (2,623) 136.0 (3,455) x 53.4 (1,357) x 94.5 (2,400) 5,890 - 6,673 (2,636 - 3,027) (3,581) 208.3 (5,292) x 53.4 (1,357) x 98.5 (2,500) 7,350 - 8,133 (3,298 - 3,689) 1,000 (3,785) 208.3 (5,292) x 53.4 (1,357) x 98.5 (2,500) 7,500 - 8,283 (3,111 - 3,502) 1,325 (5,016) 277.8 (7,055) x 53.4 (1,357) x 96.9 (2,460) 8,365 - 9,148 (3,759 - 4,150) WEATHER PROTECTED ENCLOSURE Run Time - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) Enclosure Only Steel Aluminum No Tank - 154.5 (3,923) x 54 (1,371) x 69.8 (1,772) 941 (427) 474 (215) 153 (579) 154.5 (3,923) x 54 (1,371) x 82.8 (2,102) (1,408) 154.5 (3,923) x 54 (1,371) x 94.8 (2,407) (2,230) 154.5 (3,923) x 54 (1,371) x 106.8 (2,712) (1,893) 172.6 (4,384) x 54 (1,371) x 93.8 (2,382) (2,623) 154.5 (3,923) x 54 (1,371) x 106.8 (2,712) (3,581) 208.3 (5,292) x 54 (1,371) x 110.8 (2,812) 1,000 (3,785) 208.3 (5,292) x 54 (1,371) x 110.8 (2,812) 1,325 (5,016) 277.8 (7,055) x 54 (1,371) x 109.2 (2,772) * All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. Extended and not extended tank offerings vary. Contact dealer for options. SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 0K5098 Rev. E 10/10/2024 7 of 7 SD230 | 8.7L | 230 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS* L W H L W H LEVEL 1 SOUND ATTENUATED ENCLOSURE Run Time - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) Enclosure Only Steel Aluminum No Tank - 179.9 (4,569) x 54.0 (1,371) x 70.0 (1,772) 1,246 (565) 606 (275) 153 (579) 179.9 (4,569) x 54.0 (1,371) x 83.0 (2,102) (1,408) 179.9 (4,569) x 54.0 (1,371) x 95.0 (2,407) (2,230) 179.9 (4,569) x 54.0 (1,371) x 107.0 (2,712) (1,893) 179.9 (4,569) x 54.0 (1,371) x 94.0 (2,382)) (2,623) 179.9 (4,569) x 54.0 (1,371) x 107.0 (2,712 (3,581) 208.3 (5,292) x 54.0 (1,371) x 111.0 (2,812) 1,000 (3,785) 197.8 (5,024) x 54.5 (1,384) x 105.0 (2,661) 1,325 (5,016) 277.8 (7,055) x 54.0 (1,371) x 109.4 (2,772) LEVEL 2 SOUND ATTENUATED ENCLOSURE Run Time - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) Enclosure Only Steel Aluminum No Tank - 154.5 (3,923) x 54.0 (1,371) x 93.3 (2,370) 1,482 (672) 708 (321) 153 (579) 154.5 (3,923) x 54.0 (1,371) x 106.3 (2,700) (1,408) 154.5 (3,923) x 54.0 (1,371) x 118.3 (3,005) (2,230) 154.5 (3,923) x 54.0 (1,371) x 130.3 (3,310) (1,893) 172.6 (4,384) x 54.0 (1,371) x 117.3 (2,980) (2,623) 154.5 (3,923) x 54.0 (1,371) x 130.3 (3,310) (3,581) 208.3 (5,292) x 54.0 (1,371) x 134.3 (3,410) 1,000 (3,785) 197.8 (5,024) x 54.5 (1,384) x 128.3 (3,259) 1,325 (5,016) 277.8 (7,055) x 54.0 (1,371) x 132.7 (3,370) * All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. Extended and not extended tank offerings vary. Contact dealer for options.