GENERAC SD230 230kW Diesel Genreator Spec Sheet 0K5098
agreement
7 pages
Meeting: portal event 1074 (no meeting page on file)
Agenda item: Referral from Village Board of Trustees for a Local Waterfront Revitalization Program (LWRP) Consistency review for AT&T Lease Agreement and Special Permit to co-locate a wireless facility at 1 Van Wyck Street
Agreement / contract, 7 pages. Attached to agenda item: “Referral from Village Board of Trustees for a Local Waterfront Revitalization Program (LWRP) Consistency review for AT&T Lease Agreement and Special Permit to co-locate a wireless facility at 1 Van Wyck Street”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
14652291 Croton on Hudson.Roof SA.04-01-25
14652291 Croton on Hudson Mount Analysis Report...
14652291.Croton on Hudson.Tower Analysis.04.25.2025
14652291.Croton-On-Hudson.CDS.Rev 0.06.27.2025
14652291 2191A1DMPN Croton On Hudson 6409InitialLetter...
Coastal Assessment Form - AT T
LWRP 2024 Updated
LWRP 2024 Updated2
Short EAF Part 1 - AT T Wireless
Extracted text
SPEC SHEET
1 of 7
Standby Power Rating
230 kW, 288 kVA, 60 Hz
Prime Power Rating*
207 kW, 259 kVA, 60 Hz
*EPA Certified Prime ratings are not available in the US or its Territories.
Image used for illustration purposes only
Codes and Standards
Not all codes and standards apply to all configura-
tions. Contact factory for details.
UL2200, UL6200, UL1236, UL489,
UL142
CSA C22.2, ULC S601
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering Ahead
For over 60 years, Generac has provided innovative design and
superior manufacturing.
Generac provides superior quality by designing and manufacturing
most of its generator components, including alternators, enclosures
and base tanks, control systems and communications software.
Generac gensets utilize a wide variety of options, configurations
and arrangements, allowing us to meet the standby power needs of
practically every application.
Generac searched globally for the most reliable engines to power
our generators. We choose only engines that have already been
proven in heavy-duty industrial applications under adverse
conditions.
Generac is committed to ensuring our customers’ service support
continues after their generator purchase.
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
2 of 7
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Heavy Duty Air Cleaner
• Level 1 Fan and Belt Guards (Open Set Only)
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer
FUEL SYSTEM
• Fuel Lockoff Solenoid
• Primary Fuel Filter
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• Radiator Drain Extension
• 50/50 Ethylene Glycol Antifreeze
• 120 VAC Coolant Heater
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• GENprotect™
• 12 Leads (3-Phase, Non 600V)
• Class H Insulation Material
• Vented Rotor
• 2/3 Pitch
• Skewed Stator
• Auxiliary Voltage Regulator Power Winding
• Permanent Magnet Excitation
• Sealed Bearings
• Automated Manufacturing (Winding, Insertion,
Lacing, Varnishing)
• Rotor Dynamically Spin Balanced
• Amortisseur Winding
• Full Load Capacity Alternator
• Protective Thermal Switch
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Extended Limited Warranty (Standby Rated
Units)
• 1 Year Extended Limited Warranty (Prime Rated
Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Units Only)
ENCLOSURE (IF SELECTED)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuation Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hoods (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™- Textured Polyester Powder Coat
Paint
FUEL TANKS (IF SELECTED)
• UL 142/ULC S601
• Double Wall
• Vents
• Sloped Top
• Sloped Bottom
• Factory Pressure Tested - 2 psi
• Rupture Basin Alarm
• Fuel Level
• Check Valve In Supply and Return Lines
• RhinoCoat™- Textured Polyester Powder Coat
Paint
• Stainless Steel Hardware
CONTROL SYSTEM
Digital H Control Panel- Dual 4x20
Display
Program Functions
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable Logic
Controller
• RS-232/485 Communications
• All Phase Sensing Digital Voltage Regulator
• 2-Wire Start Capability
• Date/Time Fault History (Event Log)
• Isochronous Governor Control
• Waterproof/Sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto/Off/Manual Switch
• E-Stop (Red Mushroom-Type)
• NFPA110 Level I and II (Programmable)
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol
• Predictive Maintenance Algorithm
• Sealed Boards
• Password Parameter Adjustment Protection
• Single Point Ground
• 16 Channel Remote Trending
• 0.2 msec High Speed Remote Trending
• Alarm Information Automatically Annunciated on
the Display
Full System Status Display
• Power Output (kW)
• Power Factor
• kW Hours, Total, and Last Run
• Real/Reactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
Alarms and Warnings
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Overspeed
• Battery Voltage
• Alarms and Warnings Time and Date Stamped
• Snap Shots of Key Operation Parameters During
• Alarms and Warnings
• Alarms and Warnings Spelled Out (No Alarm
Codes)
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
3 of 7
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○Block Heater
○Oil Make-Up System
○Oil Heater
○Industrial Exhaust Silencer (Open Set Only)
FUEL SYSTEM
○Flexible Fuel Lines
○Primary Fuel Filter
ELECTRICAL SYSTEM
○10A UL Listed Battery Charger
○Battery Warmer
ALTERNATOR SYSTEM
○Alternator Upsizing
○Anti-Condensation Heater
○Tropical Coating
CIRCUIT BREAKER OPTIONS
○Main Line Circuit Breaker
○2nd Main Line Circuit Breaker
○Shunt Trip and Auxiliary Contact
○Electronic Trip Breakers
GENERATOR SET
○Extended Factory Testing
○IBC Seismic Certification
○8 Position Load Center
ENCLOSURE
○Weather Protected Enclosure
○Level 1 Sound Attenuated
○Level 2 Sound Attenuated
○Steel Enclosure
○Aluminum Enclosure
○Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○AC/DC Enclosure Lighting Kit
○Spring or Pad Vibration Isolators
FUEL TANKS (Sizes On Last Page)
○Overfill Protection Valve
○Fuel Fill Drop Tube
○5 Gal Spill Return Hose
○Tank Risers
○Florida DEP-DERM
○Vent Extensions
○Fire Rated Fuel Hose
○8 in (203.2 mm) Fill Extension
○13 in (330.2 mm) Fill Extension
CONTROL SYSTEM
○NFPA 110 Compliant 21-Light Remote
Annunciator
○Remote Relay Assembly (8 or 16)
○Remote E-Stop (Break Glass-Type, Surface
Mount)
○Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○10A Engine Run Relay
○Ground Fault Annunciator
WARRANTY
○2 Year Extended Limited Warranty
○5 Year Extended Limited Warranty
○7 Year Extended Limited Warranty
○10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○Coolant Heater Ball Valves
○Fluid Containment Pan
CONTROL SYSTEM
○Spare Inputs (x4)/Outputs (x4)
○Battery Disconnect Switch
ALTERNATOR SYSTEM
○3rd Breaker System
GENERATOR SET
○Special Testing
○Motorized Dampers
○Door Open Alarm Horn
○Enclosure Heaters
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
4 of 7
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make
Iveco/FPT
EPA Emissions Compliance
Stationary Emergency
EPA Emissions Reference
See Emission Data Sheet
Cylinder #
Type
In-line
Displacement - in3 (L)
530.91 (8.7)
Bore - in (mm)
4.61 (117)
Stroke - in (mm)
5.31 (135)
Compression Ratio
16.5:1
Intake Air Method
Turbocharged/Aftercooled
Cylinder Head
4–Valve
Piston Type
Aluminum
Crankshaft Type
Forged Steel
Engine Governing
Governor
Electronic Isochronous
Frequency Regulation (Steady State)
±0.25%
Lubrication System
Oil Pump Type
Gear
Oil Filter Type
Full-Flow Cartridge
Crankcase Oil Capacity - qt (L)
29.6 (28.0)
Cooling System
Cooling System Type
Closed
Water Pump Type
Pre-Lubed, Self Sealing
Fan Type
Pusher
Fan Speed - RPM
2,538
Fan Diameter - in (mm)
30 (762)
Fuel System
Fuel Type
Ultra Low Sulfur Diesel Fuel #2
Fuel Specifications
ASTM
Fuel Filtering (Microns)
Fuel Inject Pump Make
Electronic
Fuel Pump Type
Engine Driven Gear
Injector Type
Common Rail
Engine Type
Direct Injection
Fuel Supply Line - in (mm)
0.5 (12.7) NPT
Fuel Return Line - in (mm)
0.5 (12.7) NPT
Engine Electrical System
System Voltage
24 VDC
Battery Charger Alternator
Standard
Battery Size
See Battery Index 0161970SBY
Battery Voltage
12 VDC
Ground Polarity
Negative
ALTERNATOR SPECIFICATIONS
Standard Model
K0250124Y21
Poles
Field Type
Revolving
Insulation Class - Rotor
H
Insulation Class - Stator
H
Total Harmonic Distortion
<5%
Telephone Interference Factor (TIF)
<50
Standard Excitation
Permanent Magnet Excitation
Bearings
Single Sealed Cartridge
Coupling
Direct via Flexible Disc
Prototype Short Circuit Test
Yes
Voltage Regulator Type
Digital
Number of Sensed Phases
All
Regulation Accuracy (Steady State)
±0.25%
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
5 of 7
OPERATING DATA
POWER RATINGS - DIESEL
Standby
Three-Phase 120/208 VAC @0.8pf
230 kW
Amps: 798
Three-Phase 120/240 VAC @0.8pf
230 kW
Amps: 692
Three-Phase 277/480 VAC @0.8pf
230 kW
Amps: 346
Three-Phase 346/600 VAC @0.8pf
230 kW
Amps: 277
MOTOR STARTING CAPABILITIES (SKVA)
skVA vs. Voltage Dip
277/480 VAC 3Ø
30%
208/240 VAC 3Ø
30%
K0250124Y21
K0250124Y21
K0300124Y21
K0300124Y21
K0350124Y21
1,190
K0350124Y21
FUEL CONSUMPTION RATES*
Diesel - gph (Lph)
Fuel Pump Lift - ft (m)
Percent Load
Standby
3 (1)
25%
5.1 (19.3)
50%
9.6 (36.3)
Total Fuel Pump Flow (Combustion + Return) - gph (Lph)
75%
13.7 (51.9)
26 (98)
100%
17.0 (64.3)
*Fuel supply installation must accommodate
fuel consumption rates at 100% load.
COOLING
Standby
Coolant Flow
gpm (Lpm)
63.3 (240.0)
Coolant System Capacity
gal (L)
12.7 (49.2)
Heat Rejection to Coolant
BTU/hr (kW)
626,756 (184)
Inlet Air
cfm (m³/hr)
8,872 (251)
Maximum Operating Ambient Temperature
°F (°C)
120 (50)
Maximum Operating Ambient Temperature (Before Derate)
See Bulletin No. 0199280SSD
Maximum Additional Radiator Backpressure
in H2O (kPa)
0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby
Flow at Rated Power - cfm (m³/min)
660 (18.7)
ENGINE
Standby
Rated Engine Speed
RPM
1,800
Horsepower at Rated kW**
hp
Piston Speed
ft/min (m/min)
1,593 (486)
BMEP
psi (kPa)
336 (2,289)
**Refer to “Emissions Data Sheet” for maximu305 (2,103)m bHP for EPA and
SCAQMD permitting purposes.
EXHAUST
Standby
Exhaust Flow (Rated Output)
cfm (m³/min)
1,424 (40.4)
Maximum Allowable Backpressure
inHg (kPa)
1.5 (5.1)
Exhaust Temperature (Rated Output)
°F (°C)
955 (513)
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB
Prime - See Bulletin 0187510SSB
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
6 of 7
DIMENSIONS AND WEIGHTS*
L
W
H
L
W
H
COMPACT VARIANT
Run Time
- Hours
Usable
Capacity -
gal (L)
L x W x H - in (mm)
Weight - lbs (kg)
No Tank
-
128.0 (3,250) x 53.4 (1,357) x 57.5 (1,460)
4,325 - 5,108
(1,926 - 2,317)
153 (579)
128.0 (3,250) x 53.4 (1,357) x 70.5 (1,790)
5,330 - 6,113
(2,382 - 2,773)
(1,408)
128.0 (3,250) x 53.4 (1,357) x 82.5 (2,095)
5,752 - 6,535
(2,573 - 2,964)
(2,230)
128.0 (3,250) x 53.4 (1,357) x 94.5 (2,400)
6,169 - 6,952
(2,762 - 3,153)
(1,893)
172.6 (4,384) x 53.4 (1,357) x 81.5 (2,070)
6,388 - 7,171
(2,696 - 3,087)
(2,623)
136.0 (3,455) x 53.4 (1,357) x 94.5 (2,400)
5,890 - 6,673
(2,636 - 3,027)
(3,581)
208.3 (5,292) x 53.4 (1,357) x 98.5 (2,500)
7,350 - 8,133
(3,298 - 3,689)
1,000
(3,785)
208.3 (5,292) x 53.4 (1,357) x 98.5 (2,500)
7,500 - 8,283
(3,111 - 3,502)
1,325
(5,016)
277.8 (7,055) x 53.4 (1,357) x 96.9 (2,460)
8,365 - 9,148
(3,759 - 4,150)
WEATHER PROTECTED ENCLOSURE
Run Time
- Hours
Usable
Capacity -
Gal (L)
L x W x H - in (mm)
Weight - lbs (kg)
Enclosure Only
Steel
Aluminum
No Tank
-
154.5 (3,923) x 54 (1,371) x 69.8 (1,772)
941 (427)
474 (215)
153 (579)
154.5 (3,923) x 54 (1,371) x 82.8 (2,102)
(1,408)
154.5 (3,923) x 54 (1,371) x 94.8 (2,407)
(2,230)
154.5 (3,923) x 54 (1,371) x 106.8 (2,712)
(1,893)
172.6 (4,384) x 54 (1,371) x 93.8 (2,382)
(2,623)
154.5 (3,923) x 54 (1,371) x 106.8 (2,712)
(3,581)
208.3 (5,292) x 54 (1,371) x 110.8 (2,812)
1,000
(3,785)
208.3 (5,292) x 54 (1,371) x 110.8 (2,812)
1,325
(5,016)
277.8 (7,055) x 54 (1,371) x 109.2 (2,772)
* All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. Extended and
not extended tank offerings vary. Contact dealer for options.
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com
©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 0K5098
Rev. E 10/10/2024
7 of 7
SD230 | 8.7L | 230 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
DIMENSIONS AND WEIGHTS*
L
W
H
L
W
H
LEVEL 1 SOUND ATTENUATED ENCLOSURE
Run Time
- Hours
Usable
Capacity -
Gal (L)
L x W x H - in (mm)
Weight - lbs (kg)
Enclosure Only
Steel
Aluminum
No Tank
-
179.9 (4,569) x 54.0 (1,371) x 70.0 (1,772)
1,246 (565)
606 (275)
153 (579)
179.9 (4,569) x 54.0 (1,371) x 83.0 (2,102)
(1,408)
179.9 (4,569) x 54.0 (1,371) x 95.0 (2,407)
(2,230)
179.9 (4,569) x 54.0 (1,371) x 107.0 (2,712)
(1,893)
179.9 (4,569) x 54.0 (1,371) x 94.0 (2,382))
(2,623)
179.9 (4,569) x 54.0 (1,371) x 107.0 (2,712
(3,581)
208.3 (5,292) x 54.0 (1,371) x 111.0 (2,812)
1,000
(3,785)
197.8 (5,024) x 54.5 (1,384) x 105.0 (2,661)
1,325
(5,016)
277.8 (7,055) x 54.0 (1,371) x 109.4 (2,772)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
Run Time
- Hours
Usable
Capacity -
Gal (L)
L x W x H - in (mm)
Weight - lbs (kg)
Enclosure Only
Steel
Aluminum
No Tank
-
154.5 (3,923) x 54.0 (1,371) x 93.3 (2,370)
1,482 (672)
708 (321)
153 (579)
154.5 (3,923) x 54.0 (1,371) x 106.3 (2,700)
(1,408)
154.5 (3,923) x 54.0 (1,371) x 118.3 (3,005)
(2,230)
154.5 (3,923) x 54.0 (1,371) x 130.3 (3,310)
(1,893)
172.6 (4,384) x 54.0 (1,371) x 117.3 (2,980)
(2,623)
154.5 (3,923) x 54.0 (1,371) x 130.3 (3,310)
(3,581)
208.3 (5,292) x 54.0 (1,371) x 134.3 (3,410)
1,000
(3,785)
197.8 (5,024) x 54.5 (1,384) x 128.3 (3,259)
1,325
(5,016)
277.8 (7,055) x 54.0 (1,371) x 132.7 (3,370)
* All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. Extended and
not extended tank offerings vary. Contact dealer for options.