73 Melrose Avenue Memo to PB 11-03-2025
site plan
1 page
Scanned/OCR — text may contain errors
From the meeting:
Planning Board — 2025-11-04
· our coverage →
Agenda item: New Business — 73 Melrose, LLC - Minor Site Plan Approval for a New Single-Family Home - 73 Melrose Avenue (79.5-4-31.2)
Site plan, 1 page. Attached to agenda item: “New Business — 73 Melrose, LLC - Minor Site Plan Approval for a New Single-Family Home - 73 Melrose Avenue (79.5-4-31.2)” (Text recovered by OCR — may contain errors.)
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
73 Melrose Ave 9-23-25 Architectual Drawings
73 Melrose Draft Minor Site Plan Resolution
73 Melrose
MELROSE-SP-DETAIL-SS 10-1-25
Melrose Exterior Finishes
Extracted text
Mayor
. Len Si
Village of Croton-on-Hudson New York Maria F.Slippen
Manager
- ENGINEERS OFFICE Bryan Healy
Stanley H. Kellerhouse Municipal Building Treasurer
Croton-on-Hudson, NY 10520.2501 Genette Toone
engineering@crotononhudson-ny.gov Engineer/Building Inspector
Asst. Engineer/Asst. Building Inspector
Ronald Wegner, P.E., CEO
James Ferguson
11/03/2025
73 Melrose Avenue — Engineering Department Memo to Planning Board
The applicant is before the Board for a Minor Site Plan Approval to construct a new Single Family
Dwelling at 73 Melrose Avenue, which is in the RA-5 Zoning District. This property received Minor Site
Plan Approval at the May 6, 2025 Planning Board meeting.
The house footprint and habitable square footage as approved at the May 6, 2025 meeting has been revised
but is still zoning compliant.
The major difference between this application and the previously approved minor site plan application is a
change to the driveway location. The previous application included a driveway that wrapped around the
house leading to a detached garage. The new application removes the long wrap-around driveway and
proposes a small driveway to an attached garage at the front of the house. This change to the Site Plan
results in a significant decrease in impervious area. As such, the applicant’s engineer has revised his
stormwater plans to reduce the amount of drywell chambers. We ask that the engineer provide calcualtions
to confirm that there will be no net increase in runoff for the 100 year storm.
Additionally, the required off-street parking spaces for this zoning district is 2 spaces. The proposed house
has a 1 car garage, and the the proposed Site Plan shows 2 cars in the driveway. Note that the cars shown in
the driveway are not contained wholly within the lot, and the parking spaces intrude on the Right-of-Way.
This is in part due to the fact that the front yard setback for this zoning district is 15 feet, so with that in
mind it is essentially impossible to have any parking spaces in the front yard that do not encroach into the
right-of-way. Similar Site Plans have been approved in the past with the same setback and driveway layout
(80 Olcott Ave approved 07-09-2019, 74 Thompson Ave approved 03-15-2023).
ee
Tel: 914-271-4783 www.crotononhudson-ny.gov engineering@crotononhudson-ny.gov
Machine-extracted for search and reference — the original PDF is the authoritative version.