17 Georgia La Carport Plans
map survey
4 pages
Meeting: portal event 986 (no meeting page on file)
Agenda item: New Business — Roane, Lewis, Architect & Applicant for Peter & Olivia Powchik, Owners -17 Georgia Lane-Located in the RA-40 1-Family Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson as Section 68.10 Block 2 Lot 5. Request for a front yard variance from Village Zoning Code Section 230-40(B) & 230-33(A) for a proposed detached carport in a front yard.
Map / plans, 4 pages. Attached to agenda item: “New Business — Roane, Lewis, Architect & Applicant for Peter & Olivia Powchik, Owners -17 Georgia Lane-Located in the RA-40 1-Family Residential District and designated on the Tax Maps of the Village of Croton-on-Hudson ”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
17 Georgia Lane Letter of Support K. Santone
17 Georgia Lane-Application 2024 Redacted
17 Georgia driveway
S-1 Zoning Photos-S-1 ZONING PHOTOS
Extracted text
LENGTH
SPAN
CLEAR
specified nails in
Equal number of
end distance
Provide minimum 1"
each end
END
LENGTH
EACH SIDE OF STUD
(3)10dx1 1/2" NAILS
W
DIAMETER
BOLT
+
1"
L
SIMPSON STRONG-TIE
STRAP TIES
(CS16)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
ADJUSTABLE & STANDOFF POST BASE
(ABA44)
AT EA. POST ANCHORED TO CONCRETE
SIMPSON STRONG-TIE
STUD PLATE TIES (LIGHT GAUGE STEEL)
(SP4 / SSP)
SSP FOR SINGLE STUD
(2) SSP FOR DOUBLE STUD
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
BEARING PLATE
(BP)
BASE PLATE @ EA. ANCHOR BOLT TO
FOUNDATION
(3)10dx1 1/2" NAILS
SP4
SSP
Simpson Strong-Tie
FTA
SIMPSON STRONG-TIE
FLOOR TIE ANCHORS
(FTA / LFTA)
INSTALLED @ 32"O.C.
SIMPSON Strong-Tie
SIMPSON Strong-Tie
@
sheathing
LTP4 on
plywood
G
May not be
installed over
sheathing
A35F
J
H
SIMPSON STRONG-TIE
STRAP TIES
(MSTI)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
FRAMING ANGLES & PLATES
(LTP4 / A35F)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
TWIST STRAP
(MTS)
INSTALLED @ 32"O.C.
SIMPSON STRONG-TIE
COILED STRAP (LIGHT GAUGE STEEL)
ADJUSTABLE LIGHT SLOPEABLE / SKEWABLE U HANGER
(CS20 / LSSU28)
INSTALLED @ 32"O.C.
CS20 FOR RIDGE
COMBINATION CS20 / LSSU28 FOR STRUCTURAL RIDGE
LSSU28
LSSU28
SIMPSON STRONG-TIE
ADJUSTABLE LIGHT SLOPEABLE /
SKEWABLE U HANGER
(LSSU28)
INSTALLED @ 32"O.C.
AREA OF WORK
(CARPORT)
50'-0"
34'-8"
45'-9"
54'-0"
278'-9"
17 GEORGIA LANE
CROTON ON HUDSON NY 10520
DRAWING LIST
A-1
COVER SHEET
GENERAL NOTES & DETAILS
REVISION
DATE
ISSUE
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
7/22/2024
ISSUED FOR OWNER REVIEW
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER THE
DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND SURVEYOR, TO
ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINER OR
LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR LAND SURVEYOR
SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION "ALTERED BY"
FOLOWED BY HIS OR HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION
DRAWING NUMBER
SCALE
DATE
DRAWING TITLE
PROJECT NAME
PROPOSED CARPORT FOR THE:
POWCHIK RESIDENCE
17 GEORGIA LANE
CROTON-ON-HUDSON NY 10520
COVER SHEET
A-1
SITE PLAN
SCALE 1"=30'-0"
A-2
TOWN ZONING REQUIREMENTS
ZONE:
SETBACKS
FRONT
REAR
1 SIDE
ALLOWED
N/A
5'-0"
5'-0"
RA-40
EXISTING
PROPOSED
LOT SIZE
40,000SQFT
54,866 SQFT
LOT WIDTH
150.0' MIN
160.9'
N/A
MAX HEIGHT
15'-0"
N/A
ZONING DATA
7/16/2024
AS NOTED
R310.1.1 OPERATIONAL CONSTRAINTS
EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE
INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS.
R905.2.5 FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS STEEL,
ALUMINUM OR COPPER ROOFING NAILS, MIN. 12 GAGE SHANK W/ A MIN. 3/8" HEAD ASTMF
1667, OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIAL AND A MIN. OF 3/4"
INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN 3/4" THICK, THE
FASTENERS SHALL PENETRATE THROUGH THE SHEATHING. FASTENERS SHALL COMPLY W/
ASTM F 1667.
R905.2.7 ICE SHIELD
ALL ROOF EAVES SHALL BE PROVIDED WITH ICE SHIELD MEMBRANE FROM EDGE TO 24"
PAST INSIDE WALL
SMOKE DETECTORS:
SMOKE DETECTORS SHALL BE INSTALLED AS PER THE RESIDENTIAL NEW YORK STATE
BUILDING CODE SUPPLEMENT SECTION AJ504
R905.1.1 UNDERLAYMENT APPLICATION
FOR ROOF SLOPES FROM TWO VERTICAL UNITS IN 12 UNITS HORIZ. UP TO
FOUR UNITS VERT. IN 12 UNITS HORIZ. UNITS SHALL BE TWO LAYERS.
R905.2.6 ATTACHMENT
ASPHALT ROOF SHINGLES SHALL HAVE A MIN. OF SIX FASTENERS PER SHINGLE WHERE THE
ROOF IS IN ONE OF THE FOLLOWING CATEGORIES - THE BASIC WIND SPEED PER R301.2(4) IS
110 MPH OR GREATER AND THE EAVE IS 20' OR HIGHER ABOVE GRADE .
R310.2.1 MINIMUM OPENING WIDTH
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 20 INCHES.
R310.2.2 MINIMUM OPENING HEIGHT
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES.
R310.2.1 MINIMUM OPENING AREA
AL EMERGENCY ESCAPE AND RESCUE OPENINGS SHAL HAVE A MINIMUM NET CLEAR
OPENING OF 5.7 SQ. FT. EXCEPTION GRADE FLOOR OPENINGS SHAL HAVE A MINIMUM NET
CLEAR OPENING OF 5 SQ. FT.
EGRESS WINDOWS:
TABLE 1607.1
MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
TABLE R303.1
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
PROPOSED PROJECT SHALL COMPLY WITH THE FOLLOWING:
TABLE R602.3(1)
FASTENERS SCHEDULE FOR STRUCTURAL MEMBERS
GUARDRAILS AND HANDRAILS
STAIRS
SLEEPING ROOMS
ROOMS OTHER THAN SLEEPING
ATTICS WITH STORAGE
ATTICS WITHOUT STORAGE
PASSENGER VEHICLE GARAGES
DECKS
EXTERIOR BALCONIES
LIVE LOADS
USE
MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
(IN LBS. PER SQ. FT.)
DESIGN CRITERIA
SECTION R302 TABLE 302.1 ALL CONSTRUCTION WITH-IN 5'-0" OF PROPERTY LINE TO BE 1HR
RATED. BEYOND 5'-0" NO RATING IS REQUIRED
YES
SLIGHT TO
MODERATE
MODERATE TO
HEAVY
3'-6"
SEVERE
C
30LB/FT
FLOOD HAZARDS
ICE SHEILD
UNDERLAYMENT
REQUIRED
WINTER
DESIGN
TEMP.
DECAY
TERMITE
FROST LINE
DEPTH
WEATHERING
SUBJECT TO DAMAGE FROM
SEISMIC
DESIGN
CATEGORY
GROUND
SNOW
LOAD
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
WIND SPEED
(MPH) REGION
FIRM MAP DEC 199
HEATING DEGREE DAYS
SECTION 303.1
LIGHT & VENT
SECTION R310
EMERGENCY ESCAPE
SECTION R1609.1.1
WIND-BORNE DEBRIS
SECTION 905.1.2
ICE SHIELD
SECTION R406
WATERPROOFING & DAMPPROOFING
SECTION R406.3.2
VAPOR BARRIER
SECTION R403.1.6
ANCHOR BOLTS
SECTION R403.3.4
TERMITE SHIELD
ALL FRAMING SHALL COMPLY WITH NYS R802
LOT DEPTH
200.0' MIN
353.65'
SETBACKS
ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICIAN
NOTES:
LIGHTING FIXTURES NOTED ARE TO BE SUPPLIED BY OWNER & INSTALLED BY
G.C.
IT IS A VIOLATION FOR ANY PERSON, UNLESS HE OR SHE IS ACTING UNDER
THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND
SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF
AN ENGINEER OR LAND SURVEYOR IS ALTERED, THE ALTERING ENGINEER OR
LAND SURVEYOR SHAL AFFIX TO THE ITEM HIS OR HER SEAL AND THE
NOTATION "ALTERED BY" FOLOWED BY HIS OR HER SIGNATURE AND THE
DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION
BASED UPON NFIP FIRM MAP THE PROJECT IS IN THE 'X' FLOOD ZONE
THIS PROJECT WAS DESIGNED USING THE CURRENT NYS BUILDING CODE (2020 NYS RESIDENTIAL BUILDING CODE)
PROPOSED PROJECT SHALL COMPLY WITH THE FOLLOWING ADDITIONAL SECTIONS OF 2020 NYS RESIDENTIAL BUILDING CODE
SURVEY AS PROVIDED BY HOME OWNER
ALL WORK SHALL CONFORM TO THESE DRAWINGS, THE NEW YORK
STATE BUILDING CODE AND ANY OTHER APPLICABLE CODES OR
ORDINANCE THAT MAY APPLY TO THIS PROJECT
ALL DECK FRAMING LUMBER TO BE PRESSURE TREATED
SOUTHERN YELLOW PINE (#2 OR BETTER)
ALL CONCRETE FOOTINGS SHALL CONFORM TO ACI 318.77, AND DEVELOP A
STRENGTH OF 3,000PSI BEARING IN 28 DAYS
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS,
EXISTING & PROPOSED, ANY DISCREPANCY SHALL BE REPORTED
IMMEDIATELY TO THE ARCHITECT.
THIS CARPORT HAS BEEN DESIGNED FOR
LIVE LOAD 40 LBS/SQFT
DEAD LOAD 10 LBS /SQFT
SOIL BEARING 3,000 LBS/ SQFT (ASSUMED)
LOADING
DECK FRAMING SHALL COMPLY WITH NYS R507 2020 NYS RESIDENTIAL CODE &
(FIGURE 507.2.1(2), 507.2.3 (1), 507.2.3 (2))
IF LEDGE ROCK IS ENCOUNTERED FOOTING ARE TO BE PINNED TO
THE LEDGE WITH (3) 6" #4 REBAR WITH 3" MIN EMBEDMENT INTO
THE STONE
BOTH SIDES
1.26 ACRE
34'-8"
287'-9"
45'-6"
12'-0"
N/A
N/A
CONSTRUCTION PLANS
A-3
160.9'
353.65'
54,866 SQFT
1.26 ACRE
JOIST TO SILL OR GIRDER, TOE NAIL
3-8d
DESCRIPTION OF BUILDING ELEMENTS
NUMBER & TYPE OF FASTENER
a, b, c, d
SPACING OF FASTENERS
-
1"x6" SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL
-
-
2-8d
2 STAPLES, 1-3/4
-
2" SUBFLOOR TO JOIST OR GIRDER, BLIND & FACE NAIL
2-16d
16" O.C.
16d
SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL
-
2-16d
TOP OR SOLE PLATE TO STUD, END NAIL
-
3-8d OR 2-16d
STUD TO SOLE PLATE, TOE NAIL
10d
DOUBLE STUDS, FACE NAIL
24" O.C.
24" O.C.
10d
DOUBLE TOP PLATES, FACE NAIL
SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS
3-16d
16" O.C.
-
8-16d
DOUBLE TOP PLATES, MINIMUM 48-INCH OFFSET OF END JOINTS, FACE NAIL IN
LAPPED AREA
-
3-8d
BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL
8d
RIM JOIST TO TOP PLATE, TOE NAIL
6" O.C.
-
2-10d
TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL
16" O.C. ALONG EACH EDGE
16d
BUILT-UP HEADER, TWO PIECES WITH 1
2" SPACER
16" O.C. ALONG EACH EDGE
16d
CONTINUED HEADER, TWO PIECES
CEILING JOISTS TO PLATE, TOE NAIL
3-8d
-
-
4-8d
CONTINUOUS HEADER TO STUD, TOE NAIL
3-10d
CEILING JOIST, LAPS OVER PARTITIONS, FACE NAIL
-
3-10d
CEILING JOIST TO PARALELL RAFTERS, FACE NAIL
-
2-16d
RAFTER TO PLATE, TOE NAIL
-
2-8d
2 STAPLES, 1-3/4
1" BRACE TO EACH STUD AND PLATE, FACE NAIL
-
-
-
-
2-8d
2 STAPLES, 1-3/4
1"x6" SHEATHING TO EACH BEARING, FACE NAIL
-
-
2-8d
3 STAPLES, 1-3/4
1"x8" SHEATHING TO EACH BEARING, FACE NAIL
3-8d
4 STAPLES, 1-3/4
WIDER THAN 1"x8" SHEATHING TO EACH BEARING, FACE NAIL
-
-
10d
BUILT-UP CORNER STUDS
24" O.C.
10d
BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS
NAIL EACH LAYER AS FOLLOWS:
32" O.C. AT TOP AND BOTTOM AND
STAGGERED. TWO NAILS AT ENDS AND AT
EACH SPLICE.
AT EACH BEARING
2-16d
2" PLANKS
4-16d
3-16d
ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS:
TOE NAIL
FACE NAIL
-
-
-
3-8d
RAFTER TIES TO RAFTERS, FACE
WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND WALL SHEATHING TO FRAMING, AND PARTICLEBOARD WALL SHEATHING TO FRAMING
12g
16 - 1
6d COMMON NAIL (SUBFLOOR, WALL)
8d COMMON NAIL (ROOF)f
12g
8d COMMON NAIL
32 - 1
10d COMMON NAIL OR 8d DEFORMED NAIL
1 1
8 - 1 1
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1)
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1) continued
DESCRIPTION OF BUILDING MATERIALS
2" REGULAR CELLULOSIC FIBERBOARD
SHEATHING
DESCRIPTION OF FASTENERS
b, c, d, e
1 1
2 GALVANIZED ROOFING NAIL 6d
COMMON NAIL STAPLE 16 GA., 1 1
2 LONG
SPACING OF FASTENERS
INTERMEDIATE SUPPORTS (INCHES) c, e
OTHER WALL SHEATHING h
2 STRUCTURAL CELLULOSIC FIBERBOARD
SHEATHING
1 1
2 GALVANIZED ROOFING NAIL 8d
COMMON NAIL STAPLE 16 GA., 1 1
2 LONG
32 STRUCTURAL CELLULOSIC FIBERBOARD
SHEATHING
1 3
4 GALVANIZED ROOFING NAIL 8d
COMMON NAIL STAPLE 16 GA., 1 3
4 LONG
2 GYPSUM SHEATHING
1 1
2 GALVANIZED ROOFING NAIL; 6d
COMMON NAIL; STAPLE GALVANIZED, 1 1
LONG; 1 1
4 SCREWS, TYPE W OR S
8 GYPSUM SHEATHING
1 3
4 GALVANIZED ROOFING NAIL; 8d
COMMON NAIL; STAPLE GALVANIZED, 1 5
LONG; 1 5
8 SCREWS, TYPE W OR S
WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING
4 AND LESS
6d DEFORMED NAIL OR 8d COMMON
NAIL
8 - 1
8d COMMON NAIL OR 8d DEFORMED
NAIL
1 1
8 - 1 1
10d COMMON NAIL OR 8d DEFORMED
NAIL
EDGES (INCHES) i
FOR SI: 1 INCH = 25.4mm, 1 FOOT = 304.8mm, 1 MILE PER HOUR = 1.609km/h
a.
ALL NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE
BENDING YIELD STRENGTHS AS FOLLOWS: 80ksi (551Mpa) FOR SHANK DIAMETER OF 0.192" (20d COMMON NAIL), 90ksi (620Mpa) FOR SHANK DIAMETERS LARGER THAN 0.142" BUT NOT LARGER THAN 0.177",
AND 100ksi (689Mpa) FOR SHANK DIAMETERS OF 0.142" OR LESS.
STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7
16 INCH ON DIAMETER CROWN WIDTH.
b.
NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER.
c.
4-FOOT-BY-8-FOOT OR 4-FOOT-BY-9-FOOT PANELS SHALL BE APPLIED VERTICALLY.
d.
SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(1).
e.
FOR REGIONS HAVING BASIC WIND SPEED OF 110mph OR GREATER, 8d DEFORMED NAILS SHALL BE USED FOR ATTACHING PLYWOOD AND WOOD STRUCTURAL PANEL ROOF SHEATHING TO FRAMING
WITHIN MINIMUM 48 INCH DISTANCE FROM GABLE END WALLS, IF MEAN ROOF HEIGHT IS MORE THAN 25 FEET, UP TO 35 FEET MAXIMUM.
f.
FOR REGIONS HAVING BASIC WIND SPEED OF 110mph OR LESS, NAILS FOR ATTACHING WOOD STRUCTURAL PANEL ROOF SHEATHING TO GABLE END WALL FRAMING SHALL BE SPACED 6 INCHES ON
CENTER. WHEN BASIC WIND SPEED IS GREATER THAN 100mph, NAILS FOR ATTACHING PANEL ROOF SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE SPACED 6 INCHES ON CENTER FOR MINIMUM 48
INCH DISTANCE FROM RIDGES, EAVES AND GABLE END WALLS; AND 4 INCHES ON CENTER TO GABLE END WALL FRAMING.
g.
GYPSUM SHEATHING SHALL CONFORM TO ASTM C 79 AND SHALL BE INSTALLED IN ACCORDANCE WITH GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C 208.
h.
SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND AT ALL FLOOR PERIMETERS ONLY. SPACING OF FASTENERS ON ROOF
SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND AT ALL ROOF PLANE PERIMETERS. BLOCKING OF ROOF OR FLOOR SHEATHING PANEL EDGES
PERPENDICULAR TO THE FRAMING MEMBERS SHALL NOT BE REQUIRED EXCEPT AT INTERSECTION OF ADJACENT ROOF PLANES. FLOOR AND ROOF PERIMETER SHALL BE SUPPORTED BY FRAMING
MEMBERS OR SOLID BLOCKING.
i.
1.
GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND VERIFY LOCAL
REQUIREMENTS WITH LOCAL BUILDING OFFICIALS.
2.
ALL DIMENSIONS AND CONDITIONS TO BE VERIFIED BY CONTRACTOR PRIOR TO
CONSTRUCTION AND PRIOR TO ORDERING MATERIALS.
3.
RECORD ARCHITECT / ENGINEER OR DESIGN CONSULTANTS ARE NOT TO FIELD
SUPERVISE OR INSPECT THIS PROJECT.
4.
ALL CONCRETE SHALL BE MIXED AND PLACED IN ACCORDANCE WITH THE LATEST A.C.I.
3500 PSI MIN. AT 28 DAY TEST (A.C.I. 319-63).
5.
ALL FOUNDATIONS AND FOOTINGS SIZED FOR BEARING ON UNDISTURBED SOIL AT MINIMUM
BEARING CAPACITY OF (2) TONS PER SQ. FT. MINIMUM OF 3' COVER.
6.
ALL WOOD FRAMING , INCLUDING JOISTS, BEAMS, POSTS, STUDS ETC. TO BE DOUGLAS
FIR CONSTRUCTION GRADE OR BETTER @ fd1200 PSI.
7.
WOOD SILLS ON SLAB TO BE (2) 2x6 CCA WOLMINIZED LUMBER W/ 1/2" DIA. ANCHOR
BOLTS 4'-0" O.C.
8.
ELECTRIC WORK TO BE IN ACCORDANCE W/ N.E.C. AND TO BE CERTIFIED BY THE BOARD
OF FIRE UNDERWRITERS.
9.
NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALE.
10.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE AND COMPLY WITH W/ NYS 2020
RESIDENTIAL BUILDING CODE
GENERAL NOTES
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILE FOR AND OBTAIN ALL
REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL GOVERNING AGENCIES
HAVING JURISDICTION OVER THIS PROJECT.
11.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH THE RESIDENTIAL
CODE OF NEW YORK STATE AND ALL OTHER APPLICABLE CODES, LAWS, RULES AND
REGULATIONS IN THE CONSTRUCTION OF THIS PROJECT.
12.
ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS AND WIRING SHALL BE U.I. CERTIFIED
AND INSTALLED IN COMPLIANCE WITH WITH ALL APPLICABLE ELECTRICAL CODES.
13.
ALL CONCRETE TO BE 3500 PSI. 28 DAY TEST. PROVIDE 1
2" INCH DIAMETER ANCHOR
BOLTS SPACED A MAXIMUM OF 6'-0" O.C. ANCHOR BOLTS SHALL ALSO BE LOCATED
WITHIN 12' FROM THE ENDS OF EACH PLATE SECTION EXCEPTION FOUNDATION ANCHOR
STRAPS, SPACED AS REQUIRED TO PROVIDE EQUIVALENT ANCHORAGE TO 1
2" INCH
DIAMETER ANCHOR BOLTS.
14.
NO CONSTRUCTION OR DEMOLITION SHALL COMMENCE PRIOR TO THE ISSUANCE OF
THE BUILDING PERMIT.
15.
THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE AND INSURANCE
CERTIFICATES.
16.
THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO SAFE GUARD THE
EXISTING RESIDENCE AND CONTENTS AGAINST DAMAGE FROM THE ELEMENTS DURING
CONSTRUCTION.
17.
THE CONTRACTOR SHALL REPAIR ALL EXISTING CONDITIONS DAMAGED DUE TO THE
EXECUTION OF THIS WORK TO ITS ORIGINAL CONDITION.
18.
THE DRAWINGS ARE NOT TO BE SCALED - FOLOW DIMENSIONS ONLY.
19.
NO CHANGE WILL BE PERMITTED WITHOUT PRIOR WRITTEN NOTIFICATION OF AND
APPROVAL OF THE ARCHITECT/ENGINEER OF RECORD.
20.
CONTRACTOR SHALL PROVIDE THE OWNER WITH A CERTIFICATE OF OCCUPANCY AND
AN ELECTRICAL CERTIFICATE FROM AN APPROVED AGENCY UPON COMPLETION OF THIS
PROJECT.
21.
DATE
ISSUE
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
7/22/2024
ISSUED FOR OWNER REVIEW
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER THE
DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND SURVEYOR, TO
ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINER OR
LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR LAND SURVEYOR
SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION "ALTERED BY"
FOLOWED BY HIS OR HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION
DRAWING NUMBER
SCALE
DATE
DRAWING TITLE
PROJECT NAME
PROPOSED CARPORT FOR THE:
POWCHIK RESIDENCE
17 GEORGIA LANE
CROTON-ON-HUDSON NY 10520
GENERAL NOTES & DETAILS
SCALE:
N.T.S
A-2
FASTENER SCHEDULE
SCALE:
N.T.S
A-2
GENERAL NOTES
A-2
4/16/2024
AS NOTED
REVISION
DATE
ISSUE
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
7/22/2024
ISSUED FOR OWNER REVIEW
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER THE
DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND SURVEYOR, TO
ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINER OR
LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR LAND SURVEYOR
SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION "ALTERED BY"
FOLOWED BY HIS OR HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION
DRAWING NUMBER
SCALE
DATE
DRAWING TITLE
PROJECT NAME
PROPOSED CARPORT FOR THE:
POWCHIK RESIDENCE
17 GEORGIA LANE
CROTON-ON-HUDSON NY 10520
2X2 CONCRETE
FOOTING W/
STONE VENEER
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
6X6 SUPPORT POST
WITH CEDAR
ENCLOSURE TO MATCH
HOUSE (TYP 4)
27'-0"
25'-0"
23'-0"
21'-0"
2X2 FOOTING
W/ STONE
VENEER
BEAM
OVERHEAD
BEAM
OVERHEAD
LINE OF
COVERING
LINE OF
COVERING
LINE OF
COVERING
LINE OF
COVERING
27'-0"
25'-0"
25'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
FRONT
REAR
SIDE
27'-0"
25'-0"
25'-0"
1.5x14 LVL RAFTERS 16"O.C.
6" GUTTER &
LEADERS
4'-0"
8'-0"
12'-0"
2'-0"
8'-0"
10'-0"
STONE VENEER
FOOTING
1'-0"
2'-0"
6X6 POST W/
CEDAR SIDING
"WRAP" APPROX
12" X 12"
25'-0"
23'-0"
1'-0"
2'-0"
CEDAR SIDING
BRACING
BRACING
SIDE ELEVATION
12X12 TRELLIS
8'-0"
12'-0"
1'-0"
2'-0"
1'-0"
2'-0"
STONE VENEER
FOOTING
FRONT ELEVATION
TRELLIS AT BACK OF
CARPORT (BEYOND)
1'-0"
2'-0"
1'-0"
2'-0"
STONE VENEER
FOOTING
6X6 POST
REAR ELEVATION
ROOF TO HIGH
POINT
BRACING
CONSTRUCTION PLANS
A-3
7/16/2024
AS NOTED
REVISION
DATE
ISSUE
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
7/22/2024
ISSUED FOR OWNER REVIEW
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER THE
DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND SURVEYOR, TO
ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINER OR
LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR LAND SURVEYOR
SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION "ALTERED BY"
FOLOWED BY HIS OR HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION
DRAWING NUMBER
SCALE
DATE
DRAWING TITLE
PROJECT NAME
PROPOSED CARPORT FOR THE:
POWCHIK RESIDENCE
17 GEORGIA LANE
CROTON-ON-HUDSON NY 10520
4'-4"
8'-0"
12'-4"
2'-4"
8'-0"
10'-4"
STONE VENEER
FOOTING
3'-6"
25'-0 1/2"
23'-0"
1'-0"
2'-0"
4X6 BRACING
1.5X14- 2.0 LVL RIM SUPPORT
AROUND PERIMETER
14" LVL RAFTER 16"O.C. MAX
W/ 1
2" CDX SHEATHING, ICE SHIELD
OVER ENTIRE ROOF & ASPHALT
SHINGLES AS SELECTED BY
HOMEOWNER
2X8 P.T. BRACING W/ (4) 5
8" DIA
TIMBERTECK STRUCTURAL
SCREWS EA. SIDE
2X2 CONC FOOTING
TO 42" BELOW
GRADE
#4 REBAR 12"O.C VERT
#4 REBAR @ EA. CORNER
3"
3 1/2"
1'-0"
2'-0"
3'-0"
1'-0"
3"
PROVIDE BRICK TIES
12"O.C. HORZ & VERT
STOVE VENEER CAP
EXIST DRIVEWAY
SURFACE TO REMAIN
SAWCUT AROUND FOOTING
AS REQ'D & REPAIR UPON
COMPLETION OF PROJECT
3'-6"
1'-0"
2'-0"
3"
3 1/2"
1'-0"
2'-0"
3'-0"
1'-0"
3"
STOVE VENEER CAP
SIMPSON CCQ66SDS2.5 -
STRUCTURE SCREWS TO
COLUMN & BEAM
SIMPSON HURRICANE STRAP
H2.5A @ EA. RAFTER
(2) 1.75X14 2.0 LVL HEADER W/ 3
4"
STEEL PLATE. THROUGH BOLT
(2) 1.75x14-2.0E LVL W/ 3
4"
STEEL PLATE - THRU BOLT W/
4" BOLT PER DETAIL
1.5x14-2.0E LVL
PERIMETER RIM
1.5x14-2.0E LVL
PERIMETER RIM
(2) 1.75x14-2.0E LVL W/ 3
4"
STEEL PLATE - THRU BOLT W/
4" BOLT PER DETAIL
6" ALUM GUTTER &
LEADERS
CEDAR COL WRAP - SEE DETAIL
PROVIDE (4) 5
8" STRUCTURAL
SCREWS TOP & BOTTOM
3"
6"
3"
1'-0"
3"
6"
3"
1'-0"
CEDAR TRIM TO MATCH CARPORT
CEDAR SIDING TO MATCH
CARPORT
2X BLOCKING AS REQ'D
CEDAR LATTICE W/ 12X12
LATH CENTERS - SEE DETAIL
6X6 POST
(2) 1.75X14-2.0 LVL BEAM W/ 3
4" STEEL - TO BE
FULLY ADHERED & THROUGH BOLTED
4" BOLT W/ WASHERS
EA SIDE IN EA BAY
1'-4"
1'-4"
1'-4"
4"
4"
SIMPSON HURRICANE STRAP
H2.5A @ EA. RAFTER
14" LVL RAFTER 16"O.C. MAX
W/ 1
2" CDX SHEATHING, ICE SHIELD
OVER ENTIRE ROOF & ASPHALT
SHINGLES AS SELECTED BY
HOMEOWNER
2" CDX SHEATHING, ICE SHIELD
OVER ENTIRE ROOF & ASPHALT
SHINGLES AS SELECTED BY
HOMEOWNER
8'-0"
VARRIES
1'-4"
1'-4"
(2) 1.5X14-2.0E LVL
EDGE RAFTER
METAL DRIP EDGE
2X4 STUDS 16"O.C.
2X BLOCKING
4'-0"O.C.
CEDAR TRIM TO
MATCH HOUSE
CEDAR SIDING TO
MATCH HOUSE
CEDAR SIDING TO
MATCH HOUSE
6 1/2"
6 1/2"
CLEAR
CLEAR
2 GALV
FASTENERS PER
INTERSECTION
2"W X 1
4" CEDAR
LATH @ 45 °
LATTICE
8 1/2"
8 1/2"
DETAILS
A-4
7/16/2024
AS NOTED
REVISION
DATE
ISSUE
C
LR
CROTON-ON-HUDSON, NEW YORK
A R C H I T E C T
3 WINDSOR ROAD
TEL (914) 330-1802
L E W I S C R O A N E
LEWISROANEDESIGN@GMAIL.COM
7/22/2024
ISSUED FOR OWNER REVIEW
IT IS A VIOLATION FOR ANY PERSON, UNLES HE OR SHE IS ACTING UNDER THE
DIRECTION OF A LICENSED PROFESIONAL ENGINER OR LAND SURVEYOR, TO
ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINER OR
LAND SURVEYOR IS ALTERED, THE ALTERING ENGINER OR LAND SURVEYOR
SHAL AFIX TO THE ITEM HIS OR HER SEAL AND THE NOTATION "ALTERED BY"
FOLOWED BY HIS OR HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION
DRAWING NUMBER
SCALE
DATE
DRAWING TITLE
PROJECT NAME
PROPOSED CARPORT FOR THE:
POWCHIK RESIDENCE
17 GEORGIA LANE
CROTON-ON-HUDSON NY 10520
Machine-extracted for search and reference — the original PDF is the authoritative version.