155 Grand Street R1 S S 1
site plan
6 pages
Meeting: portal event 1031 (no meeting page on file)
Agenda item: New Business — Brook Street Commercial, LLC 155 Grand Street (67.20-3-12) Minor Site Plan Application for New Home
Site plan, 6 pages. Attached to agenda item: “New Business — Brook Street Commercial, LLC 155 Grand Street (67.20-3-12) Minor Site Plan Application for New Home”
Retrieved 2026-04-15 from the village's meeting portal.
View the original PDF ↗
Also attached to this agenda item:
155 Grand Planning Narrative Exterior Finishes 032525
155 Grand Street FINAL Zoning Resolution 3.13.25
PB Application Redacted 2
Planning Board 155 Grand St Residence 2
Project Narrative 155 Grand St Draft 1
Extracted text
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-CVER
2024\24012219A\Engineering\Site Plans\C-CVER.dwg\C-100-COVER By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
SCALE : 1" = 200'
Linear unit of measure: US Survey Foot (1 ft = 1200/3937 m)
N
S
E
W
NORTH
COVER SHEET
C - 100
GENERAL INFORMATION
LOCATION MAP
INDEX OF SHEET
DESCRIPTION
SHT. No.
COVER SHEET
C - 100
EXISTING CONDITIONS & DEMOLITION PLAN
C - 200
DIMENSION PLAN
C - 300
GRADING DRAINAGE & UTILITY PLAN
C - 400
CONSTRUCTION DETAILS
C-500-501
TOTAL SHEETS
SOURCE:
NEW YORK STATE CLEARING HOUSE
PRELIMINARY SITE PLANS
FOR
155 GRAND STREET
SECTION 67.20, BLOCK 3, LOT 12
VILLAGE OF CROTON-ON-HUDSON
WESTCHESTER COUNTY, NEW YORK STATE
VILLAGE OF CROTON ON HUDSON ZONING MAP
SCALE: 1" = 500'
N
S
E
W
NORTH
PROJECT LOCATION
SOURCE: OFFICIAL ZONING MAP OF THE VILLAGE OF CROTON-ON-HUDSON
1.
THE SUBJECT PROPERTY IS KNOWN AS SECTION 67.20, BLOCK 3, LOT 12 IN THE VILLAGE OF CROTON ON HUDSON,
WESTCHESTER COUNTY, NEW YORK.
2. THE PROPERTY IS LOCATED IN THE RB (TWO-FAMILY RESIDENCE) ZONING DISTRICT. THE TAX LOT CONTAINS A
TRACT AREA OF ±5,611 S.F. / 0.13 AC.
OWNER/APPLICANT:
BROOK ST COMMERCIAL LLC
153 GRAND STREET
CROTON-ON-HUDSON, NY 10520
3. BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON IS TAKEN FROM A PLAN ENTITLED "BOUNDARY
AND TOPOGRAPHIC SURVEY FOR 153 GRAND STREET SECTION 67.20 BLOCK 3 LOTS 12 & 13." PREPARED BY COLLIERS
ENGINEERING & DESIGN; DATED JANUARY 14, 2025.
4. THE HORIZONTAL DATUM IS RELATIVE TO NAD83. THE VERTICAL DATUM IS RELATIVE TO N.A.V.D. 1988.
5. NO 100 YEAR FLOOD PLAINS ARE KNOWN TO EXIST ON THE SITE PER THE FLOOD INSURANCE RATE MAPS
36119C0109F DATED 09/28/2007 PREPARED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY.
6. THIS SET OF PLANS IS NOT DEPICTING ENVIRONMENTAL CONDITIONS OR A CERTIFICATION/WARRANTY
REGARDING THE PRESENCE OR ABSENCE OF ENVIRONMENTALLY IMPACTED SITE CONDITIONS. COLLIERS
ENGINEERING & DESIGN HAS PERFORMED NO EXPLORATORY OR TESTING SERVICES, INTERPRETATIONS,
CONCLUSIONS OR OTHER SITE ENVIRONMENTAL SERVICES RELATED TO THE DETERMINATION OF THE POTENTIAL
FOR CHEMICAL, TOXIC, RADIOACTIVE OR OTHER TYPE OF CONTAMINANTS AFFECTING THE PROPERTY AND THE
UNDERSIGNED PROFESSIONAL IS NOT QUALIFIED TO DETERMINE THE EXISTENCE OF SAME. SHOULD
ENVIRONMENTAL CONTAMINATION OR WASTE BE DISCOVERED, THE OWNER AND CONTRACTOR SHALL BE
RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE LAWS AND REGULATIONS.
7. THIS IS A SITE DEVELOPMENT PLAN AND UNLESS SPECIFICALLY NOTED ELSEWHERE HEREON, IS NOT A SURVEY.
8. DO NOT SCALE DRAWINGS AS THEY PERTAIN TO ADJACENT AND SURROUNDING PHYSICAL CONDITIONS,
BUILDINGS, STRUCTURES, ETC. THEY ARE SCHEMATIC ONLY, EXCEPT WHERE DIMENSIONS ARE SHOWN THERETO.
9. THIS SET OF PLANS HAS BEEN PREPARED FOR THE PURPOSES OF MUNICIPAL AND AGENCY REVIEW AND APPROVAL.
THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS UNTIL ALL APPROVALS REQUIRED
HAVE BEEN OBTAINED, ALL CONDITIONS OF APPROVAL HAVE BEEN SATISFIED AND THE DRAWINGS HAVE BEEN
STAMPED “ISSUED FOR CONSTRUCTION”. THIS SHALL INCLUDE APPROVAL OF ALL CATALOG CUTS, SHOP
DRAWINGS AND/OR DESIGN CALCULATIONS AS REQUIRED BY THE PROJECT OWNER AND/OR MUNICIPAL
ENGINEER.
10. THE CONTRACTOR IS RESPONSIBLE FOR PROJECT SAFETY, INCLUDING PROVISION OF ALL APPROPRIATE SAFETY
DEVICES AND TRAINING REQUIRED.
11. PRIOR TO ANY EXCAVATION, THE CONTRACTOR SHALL CALL 811 TO REQUEST A UTILITY MARKOUT.
12. INFORMATION HERON INCORPORATES THE CONTENT IN THE FOLLOWING REPORT
A.
ARCHITECTURAL PLANS "155 GRAND STREET RESIDENCE (LOT 2)" PROVIDED BY JOSEPH G. THOMPSON
ARCHITECT, PLLC DATED FEBRUARY 4, 2025.
SITE NOTES
1. BUILDING FOOTPRINT DIMENSIONS SHOWN HEREON ARE APPROXIMATE. FINAL BUILDING FOOTPRINT DIMENSIONS
FOR THE BUILDING SHALL BE FURNISHED ON THE INDIVIDUAL ARCHITECTURAL PLANS AT THE TIME OF
APPLICATION FOR A BUILDING PERMIT.
2. CURBS SHALL BE DEPRESSED FLUSH WITH PAVEMENT, AND ADA ACCESSIBLE CURB RAMPS INSTALLED WHERE
SIDEWALKS AND CROSSWALKS INTERSECT SAME. DETECTABLE WARNINGS SHALL BE INCLUDED ON ADA
ACCESSIBLE CURB RAMPS.
3. TRAFFIC SIGNAGE AND STRIPING SHALL CORRESPOND TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DISPOSAL OF ALL WASTE MATERIALS IN ACCORDANCE
WITH GOVERNING REGULATIONS AND AGENCIES.
5. REFUSE AND RECYCLABLES SHALL BE STORED WITHIN OUTSIDE SCREENED TRASH ENCLOSURES AS NOTED ON THE
PLANS AND PICKED UP BY A PRIVATE WASTE DISPOSAL HAULER.
6. THERE SHALL BE NO ON-SITE BURIAL OF CONSTRUCTION MATERIALS, TREE BRANCHES, STUMPS, OR OTHER
DELETERIOUS MATERIALS.
7. MATERIALS, WORKMANSHIP, AND CONSTRUCTION FOR THE SITE IMPROVEMENTS SHOWN HEREON SHALL BE IN
ACCORDANCE WITH:
A.
NEW YORK STATE DEPARTMENT OF TRANSPORTATION “STANDARD SPECIFICATIONS”, 2020; AS SUPPLEMENTED.
B.
CURRENT
PREVAILING MUNICIPAL, COUNTY, AND/OR
STATE
AGENCY
SPECIFICATIONS, STANDARDS,
CONDITIONS, AND REQUIREMENTS.
C.
CURRENT PREVAILING UTILITY COMPANY/AUTHORITY SPECIFICATIONS, STANDARDS, AND REQUIREMENTS.
D.
CURRENT MANUFACTURER SPECIFICATIONS, STANDARDS, AND REQUIREMENTS.
UTILITY NOTES
1. EXISTING UTILITY INFORMATION SHOWN HEREON HAS BEEN COLLECTED FROM VARIOUS SOURCES AND IS NOT
GUARANTEED AS TO ACCURACY OR COMPLETENESS. THE CONTRACTOR SHALL VERIFY ALL INFORMATION TO HIS
SATISFACTION PRIOR TO EXCAVATION. WHERE EXISTING UTILITIES ARE TO BE CROSSED BY PROPOSED
CONSTRUCTIONS, TEST PITS SHALL BE DUG BY THE CONTRACTOR PRIOR TO CONSTRUCTION TO ASCERTAIN
EXISTING INVERTS, MATERIALS, AND SIZES. TEST PIT INFORMATION SHALL BE GIVEN TO THE ENGINEER PRIOR TO
CONSTRUCTION TO PERMIT ADJUSTMENTS AS REQUIRED TO AVOID CONFLICTS. THE CONTRACTOR SHALL NOTIFY
THE UNDER SIGNED PROFESSIONAL IMMEDIATELY IF ANY FIELD CONDITIONS ENCOUNTERED DIFFER MATERIALLY
FROM THOSE REPRESENTED HEREON. SUCH CONDITIONS COULD RENDER THE DESIGNS HEREON INAPPROPRIATE
OR INEFFECTIVE.
2. UTILITY RELOCATIONS SHOWN HEREON, IF ANY, ARE FOR INFORMATIONAL PURPOSES ONLY AND MAY NOT
REPRESENT ALL REQUIRED UTILITY RELOCATIONS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING AND/OR
COORDINATING ALL REQUIRED UTILITY RELOCATIONS IN COOPERATION WITH THE RESPECTIVE UTILITY
COMPANY/AUTHORITIES.
3. STORM SEWERS SHALL BE CLASS III (OR HIGHER IF NOTED) REINFORCED CONCRETE PIPE (RCP) WITH "O" RING
GASKETS OR INTERNALLY PRELUBRICATED GASKET (TYLOX SUPERSEAL OR EQUIVALENT, ADS N-12 HIGH DENSITY
POLYETHYLENE PIPE (HDPE), AS NOTED ON THE PLAN, OR APPROVED EQUAL. PROPER PIPE COVERAGE SHALL BE
MAINTAINED DURING ALL PHASES OF CONSTRUCTION. PIPE LENGTHS SHOWN HEREON ARE FROM CENTER OF
STRUCTURE TO CENTER OF STRUCTURE.
4. WATER SERVICE TO BE PROVIDED FROM THE EXISTING WATER MAIN LINE WITHIN GRAND STREET, OWNED AND
OPERATED BY THE VILLAGE OF CROTON-ON-HUDSON. PROPOSED WATER MAIN AND FIRE HYDRANT LOCATIONS
ARE SUBJECT TO MUNICIPAL AND WESTCHESTER COUNTY DEPARTMENT OF HEALTH REVIEW AND APPROVAL. PIPE
MATERIALS SHALL BE A 1" TYPE "K" COPPER WATER PIPE AS NOTED ON THE PLANS. WATER SERVICE SHALL BE
INSTALLED TO PROVIDE A MINIMUM OF 4.5 FEET OF COVER FROM THE TOP OF PIPE TO THE PROPOSED GRADE.
5. SEWER SERVICE SHALL BE PROVIDED BY MUNICIPAL SEWER WITHIN GRAND STREET. OWNED AND OPERATED BY
THE VILLAGE OF CROTON-ON-HUDSON DEPARTMENT OF PUBLIC WORKS. PROPOSED SEWER SERVICE
CONNECTION ARE SUBJECT TO MUNICIPAL REVIEW AND APPROVAL. PIPE MATERIALS SHALL BE PVC SDR-35, EXCEPT
AS NOTED OTHERWISE ON THE PLANS. EXCEPT WHERE SHALLOWER DEPTHS ARE PERMITTED BY THE MUNICIPALITY
OR UTILITY AUTHORITY, SEWER LINES, INCLUDING FORCE MAINS AND LATERALS, SHALL BE INSTALLED TO PROVIDE
A MINIMUM 4 FEET OF COVER FROM THE TOP OF PIPE TO PROPOSED GRADE.
6. ALL WATER PIPES SHOULD BE SEPARATED FROM SANITARY SEWER LINES BY A MINIMUM HORIZONTAL DISTANCE OF
10 FEET. IF SUCH HORIZONTAL SEPARATION IS NOT POSSIBLE, THE WATER AND SEWER LINES SHALL BE IN SEPARATE
TRENCHES (STEP TRENCHES ARE PROHIBITED) WITH THE TOP OF THE SEWER LINE AT LEAST 18 INCHES BELOW THE
BOTTOM OF THE WATER MAIN ENCASED IN CONCRETE OR WITH SUCH SEPARATION EXPRESSLY APPROVED BY THE
DEPARTMENT OF HEALTH.
7. AT THE CROSSINGS OF ALL SEWER LINES AND WATER MAINS, THE TOP OF THE SEWER LINES SHALL BE AT LEAST 18
INCHES BELOW THE BOTTOM OF THE WATER MAIN. IF SUCH VERTICAL SEPARATION IS NOT POSSIBLE, THE WATER
LINE SHALL BE ENCASED IN CONCRETE SUBJECT TO THE APPROVAL OF THE PROJECT ENGINEER.
8. GAS, ELECTRIC, LIGHTING, CABLE TELEVISION, AND ELECTRICAL SERVICE PLANS, IF REQUIRED, SHALL BE PREPARED BY
THE RESPECTIVE UTILITY COMPANIES THAT SERVICE THE AREA PRIOR TO SITE CONSTRUCTION AND SHALL BE
INSTALLED PER ORDINANCE OR LOCAL UTILITY COMPANIES REQUIREMENTS.
9. TELEPHONE, ELECTRIC, AND GAS LINES WILL BE INSTALLED UNDERGROUND. CROSSINGS OF PROPOSED PAVEMENTS
WILL BE INSTALLED PRIOR TO THE CONSTRUCTION OF PAVEMENT BASE COURSE.
GRAND STREET
MT. AIRY ROAD
CHURCH STREET
RB
ZONE
RB
ZONE
C1
ZONE
RA-25
ZONE
RA-25
ZONE
GRAND STREET
MT. AIRY ROAD
CHURCH STREET
SUNSET TRAIL
MAPLE STREET
OLD POST ROAD
BAY VIEW TERRACE
ADJACENT PROPERTIES
PROJECT LOCATION
153 GRAND ST
165 GRAND ST
CROTON FIRE
DEPARTMENT
SOURCE: GOOGLE EARTH
SCALE : 1" = 100'
Linear unit of measure: US Survey Foot (1 ft = 1200/3937 m)
N
S
E
W
NORTH
151 GRAND ST
Date: 2025.03.27 13:15:40-04'00'
Digitally signed by Connor Patrick McCormack
T E R R A C E
B A Y V I E W
G R A N D
S T R E E T
LIMIT OF SAW CUT (TYP.)
LIMIT OF SAW
CUT (TYP.)
LIMIT OF SAW
CUT (TYP.)
BAYVIEW TERRACE PAVEMENT TO
BE RELOCATED WITH 18' R.O.W.
TREE T.B.R.
EXISTING TREE
TO BE REPLAED
EXISTING
TREE T.B.R.
STONE WALL TO BE
RELOCATED ALONG
PROPOSED 18' R.O.W.
MAIL BOXES TO BE RELOCATED
EXISTING
TREE T.B.R.
LIMIT OF STONE
WALL REPACEMENT
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LIMIT OF EARTH DISTURBANCE:
4,525 SQ. FT. (0.10 ACRES)
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-DEMO
2024\24012219A\Engineering\Site Plans\C-DEMO.dwg\C-200-DEMOLITION By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
SCALE : 1" = 10'
SELECT LINEAR UNIT OF MEASURE
N
S
E
W
NORTH
SITE DEMOLITION PLAN
C - 200
DEMOLITION LEGEND
TO BE REMOVED (T.B.R.)
TO BE RELOCATED
TO REMAIN
TO BE DEMOLISHED
SAWCUT LINE
DEMOLITION NOTES:
1.
IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR SHALL BE REQUIRED TO CALL THE BOARD OF PUBLIC UTILITIES ONE CALL DAMAGE PROTECTION SYSTEM FOR UTILITY
MARK OUT IN ADVANCE OF ANY EXCAVATION. UDIG NY, 811 OR WWW.UDIGNY.ORG. A PRE-DEMOLITION CONFERENCE WILL NEED TO BE ARRANGED WITH UDIG NY AND MUST
BE HELD A MINIMUM OF 7 DAYS BEFORE THE START OF ANY DEMOLITION.
2.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING SITE IMPROVEMENTS AND UTILITIES. ALL DISCREPANCIES SHALL BE IDENTIFIED TO THE ENGINEER IN WRITING.
3.
ALL DEMOLITION DEBRIS TO BE REMOVED BY CONTRACTOR IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS.
4.
ALL DEMOLITION ACTIVITIES ARE TO BE PERFORMED IN ACCORDANCE WITH THESE PLANS, AS WELL AS ALL FEDERAL, STATE AND LOCAL REGULATIONS. ANY DISCREPANCIES OR
DEVIATIONS SHALL BE IDENTIFIED BY THE CONTRACTOR TO COLLIERS ENGINEERING & DESIGN IN WRITING FOR RESOLUTION PRIOR TO INITIATION OF SITE ACTIVITY.
5.
PRIOR TO STARTING ANY DEMOLITION CONTRACTOR IS RESPONSIBLE FOR/TO:
A.
ENSURING COPIES OF ALL PERMITS AND APPROVALS MUST BE MAINTAINED ON SITE AND AVAILABLE FOR REVIEW (SEE "EROSION AND SEDIMENT CONTROL PLAN," THIS DRAWING SET).
B.
INSTALLING THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE.
C.
ALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE
LIMITS OF DISTURBANCE. THE CONTRACTOR SHALL USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL THE
UNDERGROUND UTILITIES.
D.
PROTECTING AND MAINTAINING IN OPERATION, ALL ACTIVE SYSTEMS THAT ARE NOT BEING REMOVED DURING ALL DEMOLITION ACTIVITIES.
E.
FAMILIARIZING THEMSELVES WITH THE APPLICABLE UTILITY SERVICE PROVIDER AND IS RESPONSIBLE FOR ALL COORDINATION REGARDING PROVIDER AND IS RESPONSIBLE FOR ALL
COORDINATION REGARDING UTILITY DEMOLITION REQUIRED FOR THE PROJECT. THE CONTRACTOR SHALL PROVIDE THE OWNER WRITTEN NOTIFICATION THAT THE EXISTING
UTILITIES AND SERVICES HAVE BEEN TERMINATED AND ABANDONED IN ACCORDANCE WITH JURISDICTION AND UTILITY COMPANY REQUIREMENTS.
F.
CLEAN THE EXISTING UTILITY STRUCTURES ON-SITE PRIOR TO CONSTRUCTION AND VERIFY THE INVERTS FOR CONNECTION.
6.
COLLIERS ENGINEERING & DESIGN IS NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. CONTRACTOR IS TO PROCEED WITH THE DEMOLITION IN A SYSTEMATIC AND SAFE
MANNER, FOLLOWING ALL THE O.S.H.A. REQUIREMENTS, TO ENSURE PUBLIC AND CONTRACTOR SAFETY.
7.
THE CONTRACTOR SHALL PROVIDE ALL THE "MEANS AND METHODS" NECESSARY TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF EXISTING STRUCTURES, AND ANY
OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE. THE DEMOLITION CONTRACTOR IS RESPONSIBLE FOR ALL REPAIRS OF DAMAGE TO ALL ITEMS THAT ARE TO REMAIN
AS A RESULT OF HIS ACTIVITIES. ALL REPAIRS SHALL USE NEW MATERIAL. THE REPAIRS SHALL RESTORE THE ITEM TO THE PRE-DEMOLITION CONDITION.
8.
CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH: THE "MANUAL ON UNIFORM TRAFFIC CONTROL", AS
WELL AS FEDERAL, STATE, AND LOCAL REGULATIONS WHEN DEMOLITION RELATED ACTIVITIES IMPACT ROADWAYS OR ROADWAY RIGHTS-OF-WAY.
9.
CONDUCT DEMOLITION ACTIVITIES IN SUCH A MANNER TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, SIDEWALKS, WALKWAYS, AND OTHER ADJACENT FACILITIES.
STREET CLOSURE PERMITS MUST BE RECEIVED FROM THE APPROPRIATE GOVERNMENTAL AUTHORITY (AS APPLICABLE).
10.
DEMOLITION ACTIVITIES AND EQUIPMENT SHALL NOT USE AREAS OUTSIDE THE DEFINED PROPERTY LINE WITHOUT WRITTEN PERMISSION OF THE OWNER, AND/OR APPROPRIATE
GOVERNMENT AGENCY.
11.
THIS DEMOLITION PLAN IS INTENDED TO IDENTIFY THOSE EXISTING ITEMS/CONDITIONS WHICH ARE TO BE REMOVED. IT IS NOT INTENDED TO PROVIDE DIRECTION OTHER THAN
THAT ALL METHODS AND MEANS ARE TO BE IN ACCORDANCE WITH STATE, FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL O.S.H.A. AND OTHER SAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE.
12.
DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION WASTES AND DEBRIS (SOLID WASTE) SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL TOWN, COUNTY,
STATE, AND FEDERAL LAWS AND APPLICABLE CODES.
13.
DEMOLITION SHALL NOT PROCEED UNTIL THE APPROXIMATE LOCATION OF THE EXISTING UTILITIES ARE MARKED IN THE FIELD AND ALL UTILITY CONNECTIONS ARE SUITABLY
SHUT OFF AND DISCONNECTED AND PROPER DEMOLITION PERMITS ARE IN PLACE WITH THE APPROPRIATE JURISDICTION.
14.
PROTECT ALL EXISTING UTILITIES TO REMAIN (INCLUDING DRAINAGE STRUCTURES, HYDRANTS, VALVES, SEWER MANHOLES, ETC.) DURING DEMOLITION. THE CONTRACTOR IS
RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIMSELF OR SUB-CONTRACTORS.
15.
THIS SET OF PLANS IS NOT DEPICTING ENVIRONMENTAL CONDITIONS OR A CERTIFICATION/WARRANTY REGARDING THE PRESENCE OR ABSENCE OF ENVIRONMENTALLY
IMPACTED SITE CONDITIONS. COLLIERS ENGINEERING & DESIGN HAS PERFORMED NO EXPLORATORY OR TESTING SERVICE, INTERPRETATIONS, CONCLUSIONS OR OTHER SITE
ENVIRONMENTAL SERVICES RELATED TO THE DETERMINATION OF POTENTIAL FOR CHEMICAL, TOXIC, OR RADIOACTIVE OR OTHER TYPE OF CONTAMINANTS AFFECTING THE
PROPERTY AND THE UNDERSIGNED PROFESSIONAL IS NOT QUALIFIED TO DETERMINE THE EXISTENCE OF SAME. SHOULD ENVIRONMENTAL CONTAMINATION OR WASTE BE
DISCOVERED, THE OWNER AND CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE LAW AND REGULATIONS.
REFERENCE NOTE:
1.
THE HORIZONTAL DATUM IS RELATIVE TO NAD83. THE VERTICAL DATUM IS RELATIVE TO N.A.V.D. 1988.
2.
BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON IS TAKEN FROM A PLAN ENTITLED "BOUNDARY AND TOPOGRAPHIC
SURVEY FOR 153 GRAND STREET SECTION 67.20 BLOCK 3 LOTS 12 & 13." PREPARED BY COLLIERS ENGINEERING & DESIGN; DATED
JANUARY 14, 2025.
Date: 2025.03.27 13:15:45-04'00'
Digitally signed by Connor Patrick McCormack
24'
41.25'
43.25'
12.5'
11.5'
2'
PROPOSED 3 STORY SINGLE
FAMILY RESIDENCE
1,009 S.F. (GROSS FOOTPRINT)
2,481 S.F. HABITABLE AREA)
PORCH
DOOR
LOCATION
(TYP.)
OVHD
PATIO
T E R R A C E
B A Y V I E W
G R A N D
S T R E E T
25 FOOT REAR
YARD SETBACK
8 FOOT SIDE YARD SETBACK
12 FOOT SIDE YARD
SETBACK
PROPOSED DRIVEWAY
RETAINING
WALL
8'
42.34'
8.18'
8.3'
X
X
X
X
X
X
X
X
X
X
5'
5'
10'
18'
7.52 FOOT FRONT
YARD SETBACK 2
LOT WIDTH CALCULATION1:
REAR OF DWELLING 40.61'
LOT WIDTH CALCULATION1:
FRONT OF DWELLING 47.97'
GRAVEL 3 PARKING
SPACES FOR 153
GRAND STREET
PROP.
RELOCATED
MAILBOXES (4)
1 PARKING SPACE
IN DRIVEWAY,
1 PARKING SPACE
IN GARAGE
18'
9'
18'
9'
FC
FC
CONCRETE SIDEWALK
TO BE REPLACED
22.55'
18.33'
8.08'
PROPOSED
LANDSCAPED
AREAS
PROPOSED
LANDSCAPED
AREAS
RELOCATED 10"
EVERGREEN
TREE
5' TALL FENCE
PROPOSED FLUSH CURB
WINDOW
WELL
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-LAYT
2024\24012219A\Engineering\Site Plans\C-LAYT.dwg\C-300-LAYOUT By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
LEGEND
EXISTING
PROPOSED
TRAVERSE LINE, CENTER LINE
OR BASELINE (LABEL AS SUCH)
RIGHT OF WAY LINE
PROPERTY LINE
EDGE OF PAVEMENT
CURB
DEPRESSED CURB
SIDEWALK
FENCES
TREELINE
ROADWAY SIGNS
WETLAND LINE
MUNICIPAL BOUNDARY LINE
X
X
13+00
12+00
BACK
FACE
HC
STALL COUNT
ADA ACCESSIBLE STALL
DEPRESSED CURB AND ADA RAMP
DIRECTION OF TRAFFIC FLOW
V
SCALE : 1" = 10'
SELECT LINEAR UNIT OF MEASURE
DIMENSION PLAN
C - 300
N
S
E
W
NORTH
TABLE OF BULK REQUIREMENTS
MINIMUM
REQUIRED
PROPOSED
REMARKS
LOT AREA (S.F.)
5,000 S.F.
5,611 S.F.
OK
LOT WIDTH1 (FEET)
50 FEET
44.3 FEET
VARIANCE GRANTED BY ZBA 03/13/2025
LOT DEPTH (FEET)
100 FEET
101.63 FEET
OK
FRONT YARD SETBACK2 (FEET)
7.52 FEET
8.1 FEET
OK
SIDE YARD SETBACK (ONE, FEET)
8 FEET
8 FEET
OK
SIDE YARD SETBACK (BOTH, FEET)
20 FEET
16.2 FEET
VARIANCE GRANTED BY ZBA 03/13/2025
REAR YARD SETBACK (FEET)
25 FEET
42.34 FEET
OK
MINIMUM HABITABLE FLOOR AREA PER
DWELLING UNIT (S.F.)
(TOTAL)
880 S.F.
2,481 S.F.
OK
OFF-STREET PARKING SPACES PER
DWELLING UNIT
OK
MAXIMUM
BUILDING HEIGHT (FEET)
2.5 STORIES
3 STORY
VARIANCE GRANTED BY ZBA 03/13/2025
35'
< 35'
OK
BUILDING COVERAGE
40%
36.9%
OK
FLOOR AREA RATIO
0.6
0.42
OK
ZONING DISTRICT: RB ONE-FAMILY RESIDENCE
USE: PERMITTED BY RIGHT: ONE-FAMILY DWELLING
TAX LOT:
SBL: 67.20-3-12
±5,611 S.F.
±0.13 ACRES
OWNER / APPLICANT:
BROOK ST COMMERCIAL LLC
153 GRAND STREET
CROTON-ON-HUDSON, NY 10520
1.
LOT WIDTH: THE AVERAGE DISTANCE BETWEEN SIDE LOT LINES MEASURED ALONG TWO
LINES PARALLEL TO A LINE CONNECTING THE END POINTS OF THE FRONT LOT LINE AND
DRAWN THROUGH THOSE TWO POINTS OF THE PRINCIPAL BUILDING CLOSEST TO AND
FARTHEST FROM THE STREET.
LOT WIDTH = ((47.97' + 40.61') / 2) = 44.3'
2.
FRONT YARD SETBACK: EXISTING FRONT YARD SETBACK FOR 153 GRAND STREET IS 6.37'
EXISTING FRONT YARD SETBACK FOR 165 GRAND STREET IS 8.68'
ALLOWABLE FRONT YARD SETBACK PER SECTION 230-40E = ((8.68+6.37) / 2) = 7.52'
3.
PARKING SPACES SHOWN TO THE WEST OF THE PROPOSED 3-STORY BUILDING ARE
BEING PROVIDED FOR TENANTS AT 153 GRAND STREET.
Date: 2025.03.27 13:15:45-04'00'
Digitally signed by Connor Patrick McCormack
T E R R A C E
B A Y V I E W
G R A N D
S T R E E T
DOOR
LOCATION
(TYP.)
OVHD
X
X
X
X
X
X
X
X
X
X
18'
PROP.
RELOCATED
MAILBOXES (4)
5' TALL FENCE
WINDOW
WELL
G 133.50
G 129.50
G 128.43
G 137.50
S
S
S
S
PROPOSED
WATER
CONNECTION
PROPOSED 2 STORY SINGLE
FAMILY RESIDENCE
G.F.E. = 129.50
F.F.E. = 139.0
PROPOSED
SANITARY
CONNECTION
PROPOSED 4'' PVC SDR 35 (MIN 2% SLOPE)
PROPOSED 1'' TYPE 'K'
COPPER WATER SERVICE
G 138.65
BW 133.50
TW 134.38
TW 131.45
BW 130.45
W
W
W
W
W
BW 130.83
TW 134.17
BS 133.50
BS 132.92
BS 132.33
BS 131.75
BS 131.17
G 137.25
G 137.00
G 130.50
OUTLET
INV.(OUT): 125.47 (P-3)
55 L.F. 10" HDPE @ 0.98%
(P-3)
'Y' INLET S-1
GR: 129.90
INV.(IN): 127.87 (P-6)
'Y' INLET S-2
GR: 134.59
INV.(IN): 132.10 (P-4)
INV.(OUT): 128.00 (P-1)
C/O S-3
RIM: 129.14
G 131.50
G 137.04
G 137.18
G 137.20
C/O S-6
RIM: 136.87
INV.(OUT): 131.74 (P-5)
8 L.F. 6" HDPE @ 10.00% (P-5)
C/O S-7
RIM: 131.51
INV.(IN): 130.97 (P-5)
INV.(OUT): 129.46 (P-6)
38 L.F. 6" HDPE @ 4.18% (P-6)
19 L.F. 6" HDPE @ 3.37% (P-2)
32 L.F. 6" HDPE @ 4.20% (P-1)
13 L.F. 6" HDPE @ 16.26%
(P-4)
C/O S-5
RIM: 136.82
INV.(OUT): 134.25 (P-4)
CONNECT TO EXISTING CATCH BASIN
INV.
124.90
STORMTECH
SUBSURFACE
INFILTRATORS
G 129.42
ROOF LEADER
DOWNSPOUT
CONNECTION
(TYP.)
WATER
VALVE
(TYP.)
PROPOSED SERVICE
CONNECTION
CONNECT TO EXISTING 8" SANITARY MAIN.
(INVERT TO BE CONFIRMED)
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-GRAD
2024\24012219A\Engineering\Site Plans\C-GRAD.dwg\C-400-GRADING By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
LEGEND
EXISTING
PROPOSED
TRAVERSE LINE, CENTER LINE
OR BASELINE (LABEL AS SUCH)
RIGHT OF WAY LINE
PROPERTY LINE
EDGE OF PAVEMENT
CURB
DEPRESSED CURB
SIDEWALK
FENCES
TREELINE
ROADWAY SIGNS
WETLAND LINE
MUNICIPAL BOUNDARY LINE
X
X
13+00
12+00
BACK
FACE
S
D
G 29.0
TC 29.0
BC 29.0
TDC 29.0
STORM MANHOLE
SANITARY MANHOLE
FLARED END SECTION
HEADWALL
HYDRANT
POLE MOUNTED LIGHT
CONTOURS
SPOT ELEVATION
DIRECTION OF OVERLAND FLOW
TOP OF CURB ELEVATION
BOTTOM OF CURB ELEVATION
TOP OF DEPRESSED CURB ELEVATION
H
Y
D
TYPE '9' INLET
TYPE 'C', 'D', 'E' INLET
SCALE : 1" = 10'
SELECT LINEAR UNIT OF MEASURE
GRADING, DRAINAGE
& UTILITY PLAN
C - 400
N
S
E
W
NORTH
Date: 2025.03.27 13:15:46-04'00'
Digitally signed by Connor Patrick McCormack
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-DTLS
2024\24012219A\Engineering\Site Plans\C-DTLS.dwg\C-501-DETAILS By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
CONSTRUCTION DETAILS
C-500
4,000 PSI (MIN.) CONCRETE
ASPHALT PAVEMENT
COMPACTED
SUBGRADE
1/2" R
1 1
4" R
8"
6"
1"
20" OR 18"
6"
NOTES:
1.
PREFORMED BITUMINOUS FIBER EXPANSION JOINTS, 1/2" THICK AT 20' MAX.
INTERVALS ALONG THE CURB. PROVIDE CONTROL JOINTS @ 10 FEET MAX.
BETWEEN EXPANSION JOINTS.
4" BASE COURSE, 3/4"
CRUSHED STONE
CONCRETE CURB (ASPHALT
PAVEMENT) DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-CURB-1000
X
4,000 PSI (MIN.)
GUTTER GRADE
SECTION A-A
GRADE
A
A
18"
1" MIN.
1-1/2" MAX.
NOTES:
1.
DEPRESSED VERTICAL CURB AT DRIVEWAY AND RAMP AREAS SHALL BE FULL DEPTH OF 18".
18"
18"
MIN.
6"
1" MIN.
1-1/2" MAX.
18"
MAX.
18"
MAX.
DRIVEWAY OPENING VARIES
12" PREFORMED
BITUMINOUS JOINT
6 x 6 - W10 x W10
WELDED WIRE MESH
6" THICK
CONCRETE
DRIVEWAY
APRON
EXPANSION
JOINT
6" THICK
CONCRETE
SIDEWALK
VARIES
SIDEWALK
1/2" PREFORMED
EXPANSION JOINT
FILLER
HOT POURED
RUBBER-ASPHALT
JOINT SEALER
CONCRETE CURB
12"
DEPRESSED CONCRETE CURB AT DRIVEWAY DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-CURB-1700
X
ASPHALT JOINT SEALER
TRANSITION CURB
PAVEMENT SURFACE
6"
2"
1/2" PREFORMED
BITUMINOUS JOINT
FILLER PER AASHO M-33
10'
CURB TAPER DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-CURB-1900
X
COMPACTED SUBGRADE
1.5" THICK HMA TYPE F1 TOP COURSE
3" THICK HMA TYPE F9 BINDER COURSE
6" THICK TYPE1 SUBBASE COURSE
NOTES:
1.
PAVEMENT TYPES TO BE IN ACCORDANCE WITH CURRENT NYSDOT
STANDARDS AND SPECIFICATIONS.
STANDARD ASPHALT PAVEMENT
DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-1000
X
BITUMINOUS
DRIVEWAY
DEPRESSED CURB
18"
TAPER
18"
TAPER
EXPANSION JOINTS
(TYPICAL)
CONCRETE SIDEWALK
6" CONCRETE DRIVEWAY
APRON & SIDEWALK
WITH 6 x 6 - W10 x W10
WELDED WIRE MESH, 4,000
PSI (MIN.) CONCRETE
CONCRETE CURB
VARIES
VARIES
CONCRETE DRIVEWAY
APRON DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-1400
X
4"
3" FOR 6" THICK CONCRETE
4" FOR 8" THICK CONCRETE
1" MAX.
CONTROL JOINT 1/2" DEEP x 1/4" WIDE
1/2" WIDE EXPANSION JOINT 20' O.C.
MAX.TO 1/2" RECESSED
6 x 6 - W1.4 x W1.4 (10 GA.)
WIRE MESH FABRIC
4,000 PSI (MIN.) CONCRETE
LIGHT BROOM FINISH
COMPACTED SUBBASE
3/4" CRUSHED STONE
6" OR 8"
CONCRETE PAVEMENT
DETAIL
NOT TO SCALE
MCNY-SITE-PVMT-1500
07/01/19
X
VARIES
VARIES
CONTROL JOINT
JOINT SEALANT @ 1" MAXIMUM
WIDTH SAW CUT CONTROL
JOINT
CONCRETE
PAVING
COMPACTED SUBGRADE
JOINT SEALANT @ 1" MAX. WIDTH
CONSTRUCTION/ EXPANSION JOINT
CONCRETE
PAVING
SUBBASE
SMOOTH DOWELS @ 2'-0" O.C.
ONE SIDE IN GREASED SLEEVE
COMPACTED SUBGRADE
SUBBASE
EXPANSION JOINT
CONCRETE PAVING
JOINTS DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-1700
X
W
PLAN
A
A
B
B
SEE
PLAN
SECTION A-A
SECTION B-B
CURB
4,000 PSI (MIN.) CONCRETE
LIGHT BROOM FINISH
BROOM FINISH
4" 4,000 PSI (MIN.) CONCRETE
WIDTH VARIES : REFER TO SITE PLAN
VARIES
EXPANSION JOINTS @ 20' ON CENTER
GRASS
STRIP
12" DEEP
CONTROL
JOINT @ 5'
4" OF COMPACTED
3/4" STONE
6 x 6 - W1.4 x W1.4 (10 GA.)
WIRE MESH FABRIC
4"
2% MAX. SLOPE
6 x 6 - W1.4 x W1.4 (10 GA.)
WIRE MESH FABRIC
4" OF COMPACTED 3/4" STONE
NOTES:
1.
A PREFORMED, BITUMINOUS EXPANSION JOINT 1/2" THICK, 4" WIDE AND EXTENDING THE
FULL WIDTH OF THE SIDEWALK (UNBROKEN) SHALL BE INSTALLED.
2.
½” DEEP CONTROL JOINTS INSTALLED AT AN INTERVAL OF EVERY 5'.
3.
JOINT FILLER SHALL CONFORM TO AASHTO M-33. SURFACE OF CONCRETE SHALL BE BROOM
FINISH. ROUND EDGES USING AN EDGING TOOL WITH A 1/4" RADIUS.
4.
CONCRETE SIDEWALK SHALL BE CONSTRUCTED PER THE LATEST ADA REQUIREMENTS.
FIRM,
COMPACTED,
UNYIELDING
SUBGRADE.
REINFORCED CONCRETE SIDEWALK
(NEXT TO GRASS) DETAIL
NOT TO SCALE
MCNY-SITE-PVMT-1801
07/01/19
X
EXISTING PAVEMENT
EXISTING PAVEMENT
NEW PAVEMENT
4" WIDE SEALER IN
JOINT ALL AROUND
PATCH
EXISTING
SUBGRADE
STRAIGHT SAW CUT TO
REMOVE EXISTING SURFACE
COURSE (TYP.)
EXCAVATION
SELECT BACKFILL
COMPACTED IN 6" LIFTS
NEW PAVEMENT SHALL EXTEND
6"± BEYOND LIMIT OF TRENCH
NOTCH SHALL EXTEND 6"±
INTO SURFACE COURSE OF
EXISTING PAVEMENT (1-2"
THICK)
SEE PAVEMENT
SECTION DETAIL
PAVEMENT OPENING REPAIR DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-1900
X
NOTES:
1.
MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN CONFORMANCE WITH LATEST EDITION OF THE NEW YORK STATE DEPARTMENT OF
TRANSPORTATION (N.Y.S.D.O.T.) STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS.
2.
SEE PLAN FOR SITE SPECIFIC CROSS SLOPES.
SEE PLAN FOR
SLOPES
CONCRETE SIDEWALK AT BUILDING
12" BITUMINOUS EXPANSION JOINT
SEE PAVEMENT DETAIL
REINFORCEMENT PER
SIDEWALK DETAIL
24"
6"
1'-2"
4"
CONCRETE/PAVEMENT TRANSITION DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-2000
X
WIDTH VARIES
(SEE PLAN)
2" NYSDOT ITEM 4
6" THICK TYPE 1 SUBBASE COURSE
FIRM, COMPACTED, UNYIELDING SUBBASE
GRAVEL DRIVEWAY
PAVEMENT DETAIL
NOT TO SCALE
07/01/19
MCNY-SITE-PVMT-2200
X
DESIGN
HEIGHT
MAX. 4 FT.
8"
1" - 1 1/4"
RETAINED SOIL
FOUNDATION SOIL
UNREINFORCED CONCRETE OR
CRUSHED STONE LEVELING PAD
FINISHED
GRADE
TYPICAL WALL UNIT
TYPICAL CAP UNIT
4' HIGH FENCING
(SEE NOTE 4)
8" MIN.LOW
PERMEABLE SOIL
PROPOSED SWALE
BEHIND WALL
UNIT DRAINAGE FILL
(3/4" CRUSHED
ROCK OR STONE)
APPROXIMATE LIMITS
OF EXCAVATION
4" PERFORATED PVC
DRAINAGE TILE
TYPICAL GRAVITY WALL SECTION
(MAXIMUM 4FT. DESIGN HEIGHT) DETAIL
NOT TO SCALE
NOTES:
1.
THIS DETAIL IS A SCHEMATIC REPRESENTATION FOR MUNICIPAL AND/OR AGENCY APPROVALS AND IS NOT INTENDED TO
BE USED FOR CONSTRUCTION.
2.
CONTRACTOR TO PROVIDE SITE-SPECIFIC SHOP DRAWINGS AND STRUCTURAL DESIGN CALCULATIONS FOR EACH
RETAINING WALL PREPARED BY A STATE LICENSED PROFESSIONAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO
CONSTRUCTION.
3.
MODULAR CONCRETE BLOCK WALL TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
4.
A SAFETY BARRIER (FENCING) IS REQUIRED ON ALL WALLS WHERE THE WALL HEIGHT EXCEEDS 30". PLACEMENT AND
INSTALLATION METHOD OF THE PROPOSED FENCING TO BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
X
10/01/19
MCCM-SITE-WALL-1000
Date: 2025.03.27 13:15:46-04'00'
Digitally signed by Connor Patrick McCormack
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
Engineering
& Design
Architecture, Landscape
Architecture, Surveying, CT P.C.
& Design,
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
REV
DATE
DRAWN BY
DESCRIPTION
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing
and all the information contained herein is authorized for use only by the party for
whom the services were contracted or to whom it is certified. This drawing may not
be copied, reused, disclosed, distributed or relied upon for any other purpose
without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
C-DTLS
2024\24012219A\Engineering\Site Plans\C-DTLS.dwg\C-502-DETAILS By: KYLE.SHALLOW
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGH
DEPARTMENT OF CITY PLANNING
APPROVED: _______________________
CITY PLANNING COMMISSION
_______________________
CHAIRMAN
ATTEST: _______________________
_______________________
SECRETARY
Phone:
www.colliersengineering.com
C O N S U L T I N G
ENGINEERS + SURVEYING
PRELIMINARY SITE PLAN
BROOK ST
COMMERCIAL LLC
SECTION: 67.20
BLOCK: 3
LOT: 12
VILLAGE OF
CROTON-ON-HUDSON
WESTCHESTER COUNTY
NEW YORK STATE
AS SHOWN
02/04/2025
MAS
CPM
24012219A
03/27/25
KAS
PER TOWN ENGINEER COMMENTS.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FOR
PTH
NEWBURGH
555 Hudson Valley Avenue
Suite 101
New Windsor, NY 12553
845.564.4495
COLLIERS ENGINEERING & DESIGN,
ARCHITECTURE, LANDSCAPE ARCHITECTURE,
SURVEYING CT, P.C.
Connor Patrick McCorma
NEW YORK LICENSED PROFESSIONAL ENGINEER
LICENSE NUMBER: 103756
COLLIERS ENGINEERING & DESIGN CT, P.C.
N.Y. C.O.A #: 0017609
CONSTRUCTION DETAILS
C-501
GRASS AREA
PAVED AREA
NOTES
1.
ALL PVC CLEANOUTS TO HAVE CAST IRON FRAME AND COVER PROTECTION BOX.
DESIGN FOR H20 LOADING.
CAST IRON CLEANOUT BOX SET
FLUSH WITH FINISHED GRADE
(LABEL SEWER)
PAVEMENT SECTION
(SEE DETAIL)
1/2" MIN.
NON-SHRINK
GROUT
PRECAST CONCRETE
RING 24" O.D., 8" I.D.
3/4" CRUSHED
STONE
4" PVC CLEANOUT RISER
TOP SOIL
FINISHED GRADE
18"x18"x4" SQUARE
CONCRETE MARKER
6" MIN.
2" MIN.
2"
2"
8"
4" MIN.
CLEANOUT PROTECTION
BOX DETAIL
NOT TO SCALE
X
07/01/19
MCNY-UTIL-SSWR-1600
PAVEMENT
2" CLEAR AROUND PIPE
3'-0" MIN.
4" 45° ELBOW
4" WYE BRANCH
45° BEND
SEWER MAIN
SECTION A-A
CURB FACE
PLUG
PROPERTY LINE
1'-0"
10' OR AS REQUIRED
18" X 18" X 6" CONCRETE PAD
WYE BRANCH
45° BEND
SEWER MAIN
FLOW
PLAN
A
APPROVED PVC & CIP
ADAPTER IF REQUIRED
4" PVC SDR-35
OR 4" CAST
IRON PIPE
A
CIP OR PVC
CLEANOUT WITH
BRASS CAP
18" X 18" X 6"
CONCRETE MARKER
PAD
SLOPE: 1/4" PER 1'-0"
MINIMUM
8" MINIMUM
PVC SCR-35
GRAVITY
SEWER PIPE
COMPACTED
FILL SEE
TYPICAL PIPE
BEDDING
DETAIL
UNDISTURBED
SOIL
SANITARY SEWER LATERAL & CLEANOUT DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-SSWR-1601
X
HORIZONTAL SEPARATION
VERTICAL SEPARATION
SANITARY SEWER
MAIN/LATERAL OR
STORM DRAIN
WATER MAIN
OR LATERAL
SANITARY SEWER
MAIN/LATERAL OR
STORM DRAIN
WATER MAIN/LATERAL
NOTE :
1.
NO DEVIATION IN THE SEPARATION REQUIREMENTS WILL BE PERMITTED WITHOUT
THE EXPRESS APPROVAL OF THE DEPARTMENT OF HEALTH
10'-0" MIN.
10'-0" MIN.
EQUAL
EQUAL
FULL UNCUT LENGTH OF PIPE
1'-6"
MIN.
1'-6"
MIN.
HORIZONTAL SEPARATION
VERTICAL SEPARATION
SANITARY SEWER
MAIN/LATERAL OR
STORM DRAIN
WATER MAIN
OR LATERAL
SANITARY SEWER
MAIN/LATERAL OR
STORM DRAIN
WATER MAIN/LATERAL
NOTE :
1.
NO DEVIATION IN THE SEPARATION REQUIREMENTS WILL BE PERMITTED WITHOUT
THE EXPRESS APPROVAL OF THE DEPARTMENT OF HEALTH
10'-0" MIN.
10'-0" MIN.
EQUAL
EQUAL
FULL UNCUT LENGTH OF PIPE
1'-6"
MIN.
1'-6"
MIN.
SANITARY/STORM SEWER-WATER
MAIN SEPARATION DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-SSWR-2400
X
NOTES:
1.
ALL PVC GRAVITY PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH
ASTM D2321.
2.
GRAVITY SANITARY PIPE SHALL BE PVC SDR 35 PER ASTM D3034 OR AS
REQUIRED BY THE GOVERNING AUTHORITY.
d
FINAL BACKFILL
COMPACTED
SUITABLE BACKFILL
3/4" CRUSHED STONE
BEDDING
UNDISTURBED EARTH OR
COMPACTED SUBGRADE
SPRINGLINE
6"~12"
D
MIN. TRENCH
WIDTH
O.D. + 1 FT
d = 4" FOR 12"-24" PIPE
6" FOR 30"-60" PIPE
PVC PIPE
INITIAL BACKFILL
GRADE
4' MIN.
PVC SANITARY PIPE BEDDING
(GRAVITY) DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-SSWR-2803
X
NOTE:
1" SERVICES ON DUCTILE IRON PIPE REQUIRE DIRECT TAP.
45°
GRADE
GROUND KEY CURB STOP
SIDEWALK
CURB BOX PER LOCAL REQUIREMENT
VALVE BOX (SEE PLAN FOR LOCATION)
4,000 PSI CONCRETE
BLOCK
GOOSE NECK BEND
MUELLER BRONZE SERVICE SADDLE
FOR PVC: MUELLER # H-13000
FOR DIP: MUELLER # BR2B
MUELLER CORP.
TYPE # H15008
OR APPROVED
EQUAL
1" TYPE K
COPPER TUBING
SERVICE LINE
(MIN.) SEE PLAN
FOR SIZE
WATER MAIN
3/4" STONE
4' MIN.
6"
3"
2' (TYP.)
COPPER TAIL PIECE
SIZE OF SERVICE
HOUSE WATER SERVICE CONNECTION DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-WATR-1100
X
ONE FULL LENGTH OF
WATER MAIN CENTERED
ABOVE SEWER LINE
4' MIN.
(SEE NOTE #1)
18"
MIN.
NOTES:
1.
WATER MAIN MAY CROSS ABOVE OBSTRUCTION IF 4' MINIMUM COVER IS
MAINTAINED ABOVE THE WATER MAIN TO FINISH GRADE AND 18" MINIMUM
VERTICAL SEPARATION IS OBTAINED.
MID-POINT
OF WATER
MAIN
STORM OR
SANITARY SEWER
GRADE
WATER CROSSING OVER
SEWER DETAIL
NOT TO SCALE
X
07/01/19
MCNY-UTIL-WATR-1301
4' MIN.
NOTES:
1.
VALVE BOX SHOULD HAVE EXTENSION IF WATER MAIN OR SERVICE IS PLACED
DEEPER THAN 5 FEET.
2.
CURB STOP VALVE BOX SHALL BE MUELLER EXTENSION TYPE WITH ARCH PATTERN
BASE, OR APPROVED EQUAL.
3.
WATER MAIN VALVE BOX SHALL BE SCREW TYPE ADJUSTABLE MODE, FIGURE #
4905-22 AS MANUFACTURED BY BINGHAM & TAYLOR OR APPROVED
EQUAL.
IF VALVE BOX IS NOT IN
PAVEMENT, PROVIDE 18" SQUARE
4,000 PSI CONCRETE COLLAR 6"
DEEP, AROUND THE VALVE BOX
CAST-IN WORD "WATER"
GRADE
FITTINGS AS REQUIRED
CAST IRON VALVE BOX
CURB STOP VALVE OR
WATER MAIN GATE VALVE
WITH RESILIENT SEAT
SUPPORT BOX WITH
MINIMUM OF THREE
COURSES OF BRICK
WATER MAIN /
WATER SERVICE
(SEE PLAN FOR DETAILS)
4,000 PSI CONCRETE
BEARING PAD TO BE USED
WITH PVC PIPE
SUPPORTED ON
UNDISTURBED EARTH
COMPACTED BACKFILL
TO NATURAL GROUND
MORTAR
COMPACTED
BACKFILL
VALVE
SIZE + 12"
WATER VALVE BOX DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-WATR-1600
X
DIP WATER PIPE BEDDING
DETAIL
NOT TO SCALE
NOTES:
1.
ALL PIPE SYSTEMS AND BACKFILL SHALL BE INSTALLED IN ACCORDANCE WITH
ANSI/AWWA C600.
2.
WATER MAIN PIPE SHALL BE CEMENT LINED DUCTILE IRON PIPE (DIP) PRESSURE
CLASS 150, THICKNESS CLASS 52 WITH ASPHALTIC EPOXY TYPE COATING.
3.
SUITABLE BACKFILL MATERIAL SHALL BE SAND, GRAVEL, OR 3/4" CRUSHED STONE.
d
FINAL BACKFILL
80% STANDARD PROCTOR
COMPACTED SUITABLE
BACKFILL.
UNDISTURBED EARTH OR
COMPACTED SUBGRADE
D
MIN. TRENCH
WIDTH
1.25 O.D. + 1 FT
d = 4" MINIMUM
DIP PIPE
1/8" O.D.
GRADE
4' MIN.
SUITABLE BEDDING
X
07/01/19
MCNY-UTIL-WATR-1900
SECTION B-B
B
B
6"
6" IF CONCRETE OR
CONCRETE BLOCK
8" IF BRICK
6"
6"
6"
0.31'
VARIES OVER 30"
PROVIDE M.H. STEPS
3"
3/8" - 3/4" BROKEN STONE
BASE IF DIRECTED BY THE ENGINEER
2'-0" x 2'-0"
SQUARE
GENERAL CONSTRUCTION NOTES:
1.
FOOTER TO BE CONCRETE.
2.
INVERT TO BE 4000 PSI CONCRETE.
3.
IF WALL CONSTRUCTION IS OTHER THAN CONCRETE, THE WALLS SHALL BE PLASTERED BOTH INSIDE AND OUTSIDE WITH 1/2" THICK CEMENT PLASTER.
4.
FRAME AND GRATE TO BE #3193 AS MANUFACTURED BY CAMPBELL FOUNDRY CO., OR APPROVED EQUAL.
5.
PROVIDE 3/4" DIAMETER W.I. LADDER RUNGS, 12" O.C. (IF OVER 30" DEEP)
6.
EXTERIOR OF ALL CONCRETE SHALL HAVE 2 COATS OF KOPPERS BITUMASTIC #5, OR EQUAL.
7.
ALL WORK SHALL BE WATERTIGHT. NOT FOR USE IN PAVED AREAS.
YARD INLET DETAIL
NOT TO SCALE
07/01/19
MCNY-UTIL-STRM-1400
X
FLOW
AS
REQUIRED
FROM
BUILDING
ROOF
LEADER
TO
STORM
SEWER
MAIN
18" x 18"x 6" THICK CONCRETE
COLLAR REQUIRED IN
CONCRETE / PAVED SURFACES
SCREW TYPE PLUG W/BRASS
CAP AND DEPRESSED NUT
CAST-IRON ADAPTER (CAMPBELL
# 4153 OR APPROVED EQUAL) IN
CONCRETE / PAVED SURFACES
4" HDPE RISER
4" STREET ELBOW - 45° BEND
3/4" CRUSHED STONE
6" OR 8" HDPE
(SEE PLAN)
4"x 6" OR 4"
x 8" "T" WYE
SLOPE 1/4"/FT. MIN.
ROOF LEADER
CLEANOUT DETAIL
NOT TO SCALE
X
07/01/19
MCNY-UTIL-STRM-1900
MIN. TRENCH
WIDTH
(SEE NOTE 3)
6"
d = 4" FOR 12"-24" PIPE
6" FOR 30"-60" PIPE
9" MIN.
9" MIN.
MINIMUM COVER
SEE NOTE 2.
FINAL BACKFILL
COMPACTED
SUITABLE BACKFILL
3/4" CRUSHED
STONE BEDDING
UNDISTURBED EARTH
OR COMPACTED
SUBGRADE
COMPACTED SUITABLE
CLASS III BEDDING (FOR DRY
TRENCH INSTALLATION)
D
NOTES:
1.
ALL PIPE SYSTEMS AND BACKFILL SHALL BE INSTALLED IN ACCORDANCE WITH ASTM
D2321.
2.
MINIMUM COVER FOR HDPE PIPES IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER
FOR UP TO 60" DIAMETER PIPE. PIPE COVER IS MEASURED FROM TOP OF PIPE TO THE
BOTTOM OF FLEXIBLE PAVEMENT, OR TO THE TOP OF RIGID PAVEMENT, OR TO THE
GROUND SURFACE.
3.
MINIMUM TRENCH WIDTH PER MANUFACTURER'S RECOMMENDATIONS.
SPRINGLINE
GRADE
HDPE PIPE
HDPE STORM PIPE
BEDDING DETAIL
NOT TO SCALE
X
07/01/19
MCNY-UTIL-STRM-2302
Date: 2025.03.27 13:15:46-04'00'
Digitally signed by Connor Patrick McCormack
Machine-extracted for search and reference — the original PDF is the authoritative version.