eSpire 280 Datasheet 2.28.23

site plan 2 pages
Meeting: portal event 990 (no meeting page on file)
Agenda item: Old Business — Fields, Maria, Sprocket Power - 1 Municipal Place (78.12-3-2) Amended Site Plan - Croton Auto Park for Battery Energy Storage System
Site plan, 2 pages. Attached to agenda item: “Old Business — Fields, Maria, Sprocket Power - 1 Municipal Place (78.12-3-2) Amended Site Plan - Croton Auto Park for Battery Energy Storage System”
Retrieved 2026-04-15 from the village's meeting portal. View the original PDF ↗
Also attached to this agenda item: Amended Site Plan Application Redacted Auto Park PB Resolution 10.11.11 Auto Park PB Resolution 11.12.02 CROTON AUTO PARK 9-30-24 Installation Manual 280 V1.0 Material Safety Datasheet eSpire 280 SP Sprocket Special Permit Stat-x UL 1741 SB CRD certificate eSpire 280 eSpire 280 Battery User Manual
Safe Technology & Multi-level Protection The solution uses the best-in-class Tier 1 Lithium Iron Phosphate (LFP) chemistry for the highest level of safety, thermal stability, and reliability; An integrated, multi-level Battery Management System (BMS) monitors, optimizes, and balances the system. Advanced Liquid Cooling for the Extended Battery Lifespan The unique liquid cooling system optimizes the battery thermal performance by 3 times, which extends the battery lifespan and increases your investment. Built-in Microgrid Controls with Adaptive EMS / Fleet Management Ability to integrate with solar, genset, wind, micro-turbines, utility, or other distributed energy resources. Intelligent software to reduce electricity cost, prepare for resiliency, and maximize return on investment. Remote operation & maintenance. Easy & Flexible to scale (Easy scalability) This outdoor rated, modular solution can be expanded up to 4.2 MWH capacity easily (Max. 15 unit in parallel). Turnkey System for Fast Install Fully integrated, pre-configured package system reduces on-site installation time; includes inverter(s), battery trays, racks, BMS, microgrid Controller, HVAC, fire suppression, and outdoor rated enclosure. Off-grid and Back up package available. Excellent Local Support Our US based technical support team can help you from project design to completion. Product Features • Peak shaving for demand charge management • Load shifting for time-of-use savings • Real and reactive power compensation to improve power quality • Standalone operation in off-grid mode for power backup • Store excess solar energy during the day and use at another time Supported Applications eSpire 280 COMMERCIAL AND INDUSTRIAL BATTERY STORAGE ESS includes: Inverter, battery, battery racks, BMS, HVAC, fire suppression, extraposition transformer, and outdoor rated enclosure Microgrid Control Cabinet 280 kWh ESS (battery) Figure: A typical eSpire 280 system configuration. Please note, the system configuration may vary based on application. 125 kW PCS (inverter) Communication AC Power DC Power PV System AC Power Transformer Power Conditioning System Commercial Building EV Charging Station Factory AC Distribution PV Inverter LOAD ENERGY STORAGE SYSTEM MANAGEMENT Microgrid Control Cabinet EMS Power Grid Multi-family Homes Grocery Stores & Convenience Stores Charging Stations & Service Areas Schools, Banks, & Hospitals eSpire 280 Battery Cabinet Battery Specification Fortress Power Battery Module eSpire 280 Chemistry Lithium Iron Phosphate Cell Type Prismatic Configuration IP3I2S Number of Modules Nominal Capacity 280 Ah Nominal Energy 279.5 kWh Nominal Voltage 998.4 Vdc Operating Voltage Range 873.7 - 1123.2 Vdc Maximum Continuous Charging / Discharging Current 280 Amps Peak Charging / Discharging Current 280 Amps Communication Modbus TCP, CAN, Modbus RTU Cycle Life @ 25C @ 70% Retention 8000 Cycles DC DC Round Trip Efficiency 92% @ 0.5C, 25°C, 1 Cycle Per Day Operating Temperature Range Charging: 0-55°C & Discharging -20-55°C Key Components 6 Modules, 6 Cell Supervision Circuits, 1 Slave Battery Management Unit, 6 Maintenance Switch Disconnects Thermal Management System Integrated Liquid Cooling System (HVAC) Fire Suppression System Fire Detector, Smoke Detector & Fire Extinguisher IP Class Type IP66 Battery Bank Scalability Up to 15 (4.2 mWh) www.FortressPower.com Sales@FortressPower.com • 877-497-6937 eSpire 280 COMMERCIAL AND INDUSTRIAL BATTERY STORAGE PCS Specification PCS Model 125 HV Rated AC Power 125 KVA/KW Rated Grid Voltage 3Ph 480Vac + PE Grid Voltage Range 422 to 528Vac (-12%, +10%) / (3Ph 208Vac + PE)* Rated Grid Frequency 60 Hz Grid Frequency Range 59.3 to 60.5Hz, Adjustable Rated AC Current 151 Amps DC Voltage Range 750-1350Vdc Rated Discharge / Charge Power 128KW/122KW Max. Discharge/Charge Current 157Amps/151Amps Output THDi <3% Peak Efficiency 98% Standby Loss <25W @ Cool Mode Grid Power Factor -1 (leading) to (Lagging), Continuously Adjustable Wiring Configuration 3Phase 4 Wire (3P4W Configuration) Protection DC Reverse Protection/OVP/UVP/OCP/DC Insulation Detection System Specification PCS Details Microgrid Control Panel Details Battery Details Operating Temperature -30 to 60°C, De-Rating >45°C -25 to 40°C -30 to 45°C Storage Temperature Range -25 to 55°C -15C to 45°C -40 to 60°C Dimensions (H*W*D) 2000*600*500mm 2300*600*750mm 2280*1300*1300mm Enclosure Rating NEMA 3R / IP55 NEMA 3 / IP54 NEMA 4X / IP66 Relative Humidity <95% No Condensing <95% No Condensing <95% No Condensing Max Altitude 4000m, De-Rating > 2000m 4000m, De-Rating > 2000m 4000m, De-Rating > 2000m Acoustic Noise <70 dBA, Max 75dB N/A <70dB, Max 80dB Cooling System Forced Air via Speed Control Air Cool Liquid Cooling Via HVAC Net Weight 230kg/286.6Ibs 313Kg/690Ibs 2510kg/5533.60Ibs Operation Status indicators Warning, Low Voltage & High Voltage Lockage Enclosure Swing Handle Padlockable User Interface LED, EPO, Ethernet & HMI via Web Access Communication Protocol Ethernet/Modbus TCP Certifications UL1973, UL9540[A], UL1741-SB, IEEE-1547-2018, IEEE-519, FCC Part 15 Class A (UL9540 CEC, SGIP Pending) Energy Management Software Operation Made On Grid/Economic, Off Grid/Microgrid, Blackstart Use Cases Back-up, Microgrid, Off-grid, Peak Shaving, Demand Response, Time of Use, Net Metering, Zero Export, VPP Communication Interface Modbus (TCP and RTU), TCP/IP, CANbus, BACnet, Dry Contactor, External APIs * For 3Ph 208Vac + PE application, a step-down transformer is required.